334 resultados para Controlled vocabularies


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To test the effectiveness of a complex intervention designed, within a theoretical framework, to improve outcomes for patients with coronary heart disease. Design: Cluster randomised controlled multicentre trial. Setting: General practices in Northern Ireland and the Republic of Ireland, regions with different healthcare systems. Participants: 903 patients with established coronary heart disease registered with one of 48 practices. Intervention: Tailored care plans for practices (practice based training in prescribing and behaviour change, administrative support, quarterly newsletter), and tailored care plans for patients (motivational interviewing, goal identification, and target setting for lifestyle change) with reviews every four months at the practices. Control practices provided usual care. Main outcome measures: The proportion of patients at 18 month follow-up above target levels for blood pressure and total cholesterol concentration, and those admitted to hospital, and changes in physical and mental health status (SF-12). Results: At baseline the numbers (proportions) of patients above the recommended limits were: systolic blood pressure greater than 140 mm Hg (305/899; 33.9%, 95% confidence interval 30.8% to 33.9%), diastolic blood pressure greater than 90 mm Hg (111/901; 12.3%, 10.2% to 14.5%), and total cholesterol concentration greater than 5 mmol/l (188/860; 20.8%, 19.1% to 24.6%). At the 18 month follow-up there were no significant differences between intervention and control groups in the numbers (proportions) of patients above the recommended limits: systolic blood pressure, intervention 98/360 (27.2%) v control, 133/405 (32.8%), odds ratio 1.51 (95% confidence interval 0.99 to 2.30; P=0.06); diastolic blood pressure, intervention 32/360 (8.9%) v control, 40/405 (9.9%), 1.40 (0.75 to 2.64; P=0.29); and total cholesterol concentration, intervention 52/342 (15.2%) v control, 64/391 (16.4%), 1.13 (0.63 to 2.03; P=0.65). The number of patients admitted to hospital over the 18 month study period significantly decreased in the intervention group compared with the control group: 107/415 (25.8%) v 148/435 (34.0%), 1.56 (1.53 to 2.60; P=0.03). Conclusions: Admissions to hospital were significantly reduced after an intensive 18 month intervention to improve outcomes for patients with coronary heart disease, but no other clinical benefits were shown, possibly because of a ceiling effect related to improved management of the disease. Trial registration: Current Controlled Trials ISRCTN24081411.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of the reuse of ‘Formtex’ Controlled Permeability Formwork (CPF) liner on strength and durability properties of concrete were investigated at two different water-cement ratios and the results are reported in this paper. Test blocks were cast using the CPF on one side and impermeable formwork (IF) on the opposite side of the mould so that direct comparisons could be made between the two. The strength was assessed using the Limpet pulloff tester and both the air permeability and the water absorption (sorptivity) were measured using the Autoclam Permeability System. Both these instruments measured the ‘covercrete’ properties. In addition, cores cut from the test specimens were subjected to an accelerated carbonation test and a chloride exposure test. The results showed that the ‘Formtex’ CPF increases the surface strength and the durability of concrete compared to the IF. There was an almost complete elimination of blowholes. The permeability of concrete decreased and its resistance to the ingress of both carbon dioxide and chlorides increased when CPF was used. The beneficial effects of the Formtex CPF were most evident in concrete of higher water-cement ratio. With the reuse of the Formtex liner twice, that is a total of three uses, the performance of the CPF to improve the properties of concrete remained almost the same. In this research the CPF liner was cleaned thoroughly between each use, which must be adhered to for site applications for reproducing the beneficial effects observed in the laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective
Preliminary assessment of an automated weaning system (SmartCare™/PS) compared to usual management of weaning from mechanical ventilation performed in the absence of formal protocols.


Design and setting
A randomised, controlled pilot study in one Australian intensive care unit.


Patients
A total of 102 patients were equally divided between SmartCare/PS and Control.

Interventions
The automated system titrated pressure support, conducted a spontaneous breathing trial and provided notification of success (“separation potential”).

Measurements and results
The median time from the first identified point of suitability for weaning commencement to the state of “separation potential” using SmartCare/PS was 20 h (interquartile range, IQR, 2–40) compared to 8 h (IQR 2–43) with Control (log-rank P = 0.3). The median time to successful extubation was 43 h (IQR 6–169) using SmartCare/PS and 40 (14–87) with Control (log-rank P = 0.6). Unadjusted, the estimated probability of reaching “separation potential” was 21% lower (95% CI, 48% lower to 20% greater) with SmartCare/PS compared to Control. Adjusted for other covariates (age, gender, APACHE II, SOFAmax, neuromuscular blockade, corticosteroids, coma and elevated blood glucose), these estimates were 31% lower (95% CI, 56% lower to 9% greater) with SmartCare/PS. The study groups showed comparable rates of reintubation, non-invasive ventilation post-extubation, tracheostomy, sedation, neuromuscular blockade and use of corticosteroids.

Conclusions
Substantial reductions in weaning duration previously demonstrated were not confirmed when the SmartCare/PS system was compared to weaning managed by experienced critical care specialty nurses, using a 1:1 nurse-to-patient ratio. The effect of SmartCare/PS may be influenced by the local clinical organisational context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Smoking cessation is the primary disease modifying intervention for chronic obstructive pulmonary disease (COPD).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background
Results of several trials of antioxidant use during pregnancy have not shown a reduction in pre-eclampsia, but the eff ect in women with diabetes is unknown. We aimed to assess whether supplementation with vitamins C and E reduced incidence of pre-eclampsia in women with type 1 diabetes.

Methods
We enrolled women from 25 UK antenatal metabolic clinics in a multicentre randomised placebo-controlled trial. Eligibility criteria were type 1 diabetes preceding pregnancy, presentation between 8 weeks’ and 22 weeks’ gestation, singleton pregnancy, and age 16 years or older. Women were randomly allocated in a 1:1 ratio to receive1000 mg vitamin C and 400 IU vitamin E (a-tocopherol) or matched placebo daily until delivery. The randomisation sequence was stratifi ed by centre with balanced blocks of eight patients. All trial personnel and participants were masked to treatment allocation. The primary endpoint was pre-eclampsia, which we defi ned as gestational hypertension with proteinuria. Analysis was by modifi ed intention to treat. This study is registered, ISRCTN27214045.

Findings
Between April, 2003, and June, 2008, 762 women were randomly allocated to treatment groups (379 vitamin supplementation, 383 placebo). The primary endpoint was assessed for 375 women allocated to receive vitamins, and 374 allocated to placebo. Rates of pre-eclampsia did not differ between vitamin (15%, n=57) and placebo (19%, 70)groups (risk ratio 0·81, 95% CI 0·59–1·12). No adverse maternal or neonatal outcomes were reported.

Interpretation
Supplementation with vitamins C and E did not reduce risk of pre-eclampsia in women with type 1 diabetes. However, the possibility that vitamin supplementation might be benefi cial in women with a low antioxidant status at baseline needs further testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this cluster randomised controlled trial was to test the impact of an infection control education and training programme on meticillin-resistant Staphylococcus aureus (MRSA) prevalence in nursing homes. Nursing homes were randomised to intervention (infection control education and training programme; N¼16) or control (usual practice continued; N¼16). Staff in intervention homes were educated and trained (0, 3 and 6 months) in the principles and implementation of good infection control practice with infection control audits conducted in all sites (0, 3, 6 and 12 months) to assess compliance with good practice. Audit scores were fed back to nursing home managers in intervention homes, together with a written report indicating where practice could be improved. Nasal swabs were taken from all consenting residents and staff at 0, 3, 6 and 12 months. The primary outcome was MRSA prevalence in residents and staff, and the secondary outcome was a change in infection control audit scores. In all, 793 residents and 338 staff were recruited at baseline. MRSA prevalence did not change during the study in residents or staff. The relative risk of a resident being colonised with MRSA in an intervention home compared with a control home at 12 months was 0.99 (95% con?dence interval: 0.69, 1.42) after adjustment for clustering. Mean infection control audit scores were signi?cantly higher in the intervention homes (82%) compared with the control homes (64%) at 12 months (P<0.0001). Consideration should be given to other approaches which may help to reduce MRSA in this setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An architecture to simultaneously affect both amplitude and phase control from a reflectarray element using an impedance transformation unit is demonstrated. It is shown that a wide range of control is possible from a single element, removing the conventional necessity for variable sized elements across an array in order to form a desired reflectarray far-field pattern. Parallel plate waveguide measurements for a 2.2 GHz prototype element validate the phase and amplitude variation available from the element. It is demonstrated that there is sufficient control of the element's reflection response to allow Dolph-Tschebyscheff weighting coefficients for major-lobe to side-lobe ratios of up to 36 dB to be implemented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study was undertaken to compare preprandial and postprandial capillary glucose monitoring in pregnant women with type 1 diabetes.