231 resultados para Binaries: general
Resumo:
Delivering sufficient dose to tumours while sparing surrounding tissue is one of the primary challenges of radiotherapy, and in common practice this is typically achieved by using highly penetrating MV photon beams and spatially shaping dose. However, there has been a recent increase in interest in the possibility of using contrast agents with high atomic number to enhance the dose deposited in tumours when used in conjunction with kV x-rays, which see a significant increase in absorption due to the heavy element's high-photoelectric cross-section at such energies. Unfortunately, the introduction of such contrast agents significantly complicates the comparison of different source types for treatment efficacy, as the dose deposited now depends very strongly on the exact composition of the spectrum, making traditional metrics such as beam quality less valuable. To address this, a 'figure of merit' is proposed, which yields a value which enables the direct comparison of different source types for tumours at different depths inside a patient. This figure of merit is evaluated for a 15 MV LINAC source and two 150 kVp sources (both of which make use of a tungsten target, one with conventional aluminium filtration, while the other uses a more aggressive thorium filter) through analytical methods as well as numerical models, considering tissue treated with a realistic concentration and uptake ratio of gold nanoparticle contrast agents (10 mg ml(-1) concentration in 'tumour' volume, 10: 1 uptake ratio). Finally, a test case of human neck phantom is considered with a similar contrast agent to compare the abstract figure to a more realistic treatment situation. Good agreement was found both between the different approaches to calculate the figure of merit, and between the figure of merit and the effectiveness in a more realistic patient scenario. Together, these observations suggest that there is the potential for contrast-enhanced kilovoltage radiation to be a useful therapeutic tool for a number of classes of tumour on dosimetric considerations alone, and they point to the need for further research in this area.
Resumo:
The following study considers the fragmentation of law which occurred in 1956 with regard to the law on servitude. As States were unwilling to go as far as the Universal Declaration on Human in establishing that "no one shall be held in [...] servitude", the negotiators of the 1956 Supplementary Conventions moved to expunge the very term 'servitude' from the text and to replace it with the phrase 'institutions and practices similar to slavery' which could then be abolished 'progressively and as soon as possible'. The negotiation history of the 1956 Convention clear demonstrate that the Universal Declaration on Human was the elephant in the room and that it ultimately lead to a fragmentation of the law as between general international law manifest in the 1956 Supplementary Convention on the one hand and international human rights law on the other. It is for this reason that, for instance the 2001 UN and 2005 Council of Europe trafficking conventions mention both 'practices similar to slavery' and 'servitude' as types of human exploitation to be suppressed in their definition of 'trafficking in persons'.
Resumo:
We present a general method to construct a set of local rectilinear vibrational coordinates for a nonlinear molecule whose reference structure does not necessarily correspond to a stationary point of the potential-energy surface. We show both analytically and with a numerical example that the vibrational coordinates satisfy Eckart's conditions. In addition, we find that the Watson Hamiltonian provides a fairly robust description even of highly excited vibrational states of triatomic molecules, except for a few states of large amplitude motion sampling the singular region of the Hamiltonian. These states can be identified through slow convergence.
Resumo:
We present near-infrared linear spectropolarimetry of a sample of persistent X-ray binaries, Sco X-1, Cyg X-2 and GRS 1915+105. For Sco X-1 and Cyg X-2, the polarization levels at 2.4 µm are 1.3+/-0.10% and 5.4+/-0.7%, respectively, which is greater than the polarization level at 1.65 µm. This cannot be explained by interstellar polarization or electron scattering in the anisotropic environment of the accretion flow. We propose that the most likely explanation is that this is the polarimetric signature of synchrotron emission arising from close to the base of the jet. For Sco X-1 the position angle of the radio jet on the sky is approximately perpendicular to the near-infrared position angle (electric vector), suggesting that the magnetic field is aligned with the jet. These observations may be a first step towards probing the ordering, alignment, and variability of the outflow magnetic field, in a region closer to the central accreting object than is observed in the radio band.
Resumo:
Objective: To test the effectiveness of a complex intervention designed, within a theoretical framework, to improve outcomes for patients with coronary heart disease. Design: Cluster randomised controlled multicentre trial. Setting: General practices in Northern Ireland and the Republic of Ireland, regions with different healthcare systems. Participants: 903 patients with established coronary heart disease registered with one of 48 practices. Intervention: Tailored care plans for practices (practice based training in prescribing and behaviour change, administrative support, quarterly newsletter), and tailored care plans for patients (motivational interviewing, goal identification, and target setting for lifestyle change) with reviews every four months at the practices. Control practices provided usual care. Main outcome measures: The proportion of patients at 18 month follow-up above target levels for blood pressure and total cholesterol concentration, and those admitted to hospital, and changes in physical and mental health status (SF-12). Results: At baseline the numbers (proportions) of patients above the recommended limits were: systolic blood pressure greater than 140 mm Hg (305/899; 33.9%, 95% confidence interval 30.8% to 33.9%), diastolic blood pressure greater than 90 mm Hg (111/901; 12.3%, 10.2% to 14.5%), and total cholesterol concentration greater than 5 mmol/l (188/860; 20.8%, 19.1% to 24.6%). At the 18 month follow-up there were no significant differences between intervention and control groups in the numbers (proportions) of patients above the recommended limits: systolic blood pressure, intervention 98/360 (27.2%) v control, 133/405 (32.8%), odds ratio 1.51 (95% confidence interval 0.99 to 2.30; P=0.06); diastolic blood pressure, intervention 32/360 (8.9%) v control, 40/405 (9.9%), 1.40 (0.75 to 2.64; P=0.29); and total cholesterol concentration, intervention 52/342 (15.2%) v control, 64/391 (16.4%), 1.13 (0.63 to 2.03; P=0.65). The number of patients admitted to hospital over the 18 month study period significantly decreased in the intervention group compared with the control group: 107/415 (25.8%) v 148/435 (34.0%), 1.56 (1.53 to 2.60; P=0.03). Conclusions: Admissions to hospital were significantly reduced after an intensive 18 month intervention to improve outcomes for patients with coronary heart disease, but no other clinical benefits were shown, possibly because of a ceiling effect related to improved management of the disease. Trial registration: Current Controlled Trials ISRCTN24081411.