88 resultados para Arteries Radiography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Structural and functional change in the microcirculation in type 1 diabetes mellitus predicts future end-organ damage and macrovascular events. We explored the utility of novel signal processing techniques to detect and track change in ocular hemodynamics in patients with this disease. 24 patients with uncomplicated type 1 diabetes mellitus, and 18 age-and-sex matched control subjects were studied. Doppler ultrasound was used to interrogate the carotid and ophthalmic arteries and digital photography to image the retinal vasculature. Frequency analysis algorithms were applied to quantify velocity waveform structure and retinal photographic data at baseline and following inhalation of 100% oxygen. Frequency data was compared between groups. No significant differences were found in the resistive index between groups at baseline or following inhaled oxygen. Frequency analysis of the Doppler flow velocity waveforms identified significant differences in bands 3-7 between patients and controls in data captured from the ophthalmic artery (p<0.01 for each band). In response to inhaled oxygen, changes in the frequency band amplitudes were significantly greater in control subjects compared with patients (p<0.05). Only control subjects demonstrated a positive correlation (R=0.61) between change in retinal vessel diameter and frequency band amplitudes derived from ophthalmic artery waveform data. The use of multimodal signal processing techniques applied to Doppler flow velocity waveforms and retinal photographic data identified preclinical change in the ocular microcirculation in patients with uncomplicated diabetes mellitus. An impaired autoregulatory response of the retinal microvasculature may contribute to the future development of retinopathy in such patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Previous investigators have not described some of the new anatomic variations or provided quantitative and analytical data of the arterial anatomy of the lips in as much depth as in this study. Dissections of 14 different facial sides of cadavers were done. Through investigating the arterial supply of the upper and lower lips, measurements were performed and statistically analyzed. The main arterial supply of the upper lip was from the superior labial artery (SLA, mean external diameter, 1.8 mm [SD, 0.74 mm]); in addition, the subalar and septal branches contributed to its vascularization. The origin of the SLA was above the labial commissure in 78.6%. The subalar branch was not found but replaced by the alar artery that arose from the infraorbital artery in 1 specimen. The main arterial supply of the lower lip was derived from 3 branches of the facial artery, the inferior labial artery (mean external diameters, 1.4 mm [SD, 0.31 mm]) and the horizontal and vertical labiomental arteries. The inferior labial artery originated mostly below the labial commissure in 42.9% and formed a common trunk with the SLA in 28.6%. The horizontal labiomental artery was present in all, but vertical labiomental artery was absent in 21.4% of specimens. Overall, observed anatomic variations were classified into types I to VIII. Significant relations between the demographic variables and measured parameters were reported including the correlation coefficient among evaluated parameters. In conclusion, this study provides various information that aids in creating new flaps and supports the vascular base for clinical procedures in reconstructive surgery of the lip.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The abductor hallucis flap is commonly used as a pedicled flap (distally or proximally based) in the management of ankle, heel, and mid-foot lesions, where it is ideally used for closing defects. This study investigates the anatomical details of this muscle regarding its various forms of insertion and its arterial supply in 15 cadaveric feet. Four types of insertion could be distinguished: type A, insertion at the proximal phalanx of the big toe (46.7%); type B, insertion by two slips into the base of the proximal phalanx and the sesamoid bone (33.3%); type C, insertion at the sesamoid bone (6.7%); And type D, the insertion is divided into superficial tendinous and deep fleshy parts which are attached to the base of the proximal phalanx and to the metatarsophalangeal joint capsule of the big toe, respectively (13.3%). As regards the arterial supply, three patterns were noticed: pattern A (40%) where the medial plantar artery (MPA) is divided into superficial and deep branches that supplied the muscle; pattern B (53.3%) where the MPA failed to produce a deep branch but instead continued as the superficial branch supplying the two ends of the muscle; and pattern C (6.6%) where the MPA continued as a deep branch supplying the muscle. A superficial branch of MPA provided a branch to the abductor hallucis muscle from its proximal part. In two specimens (13.3%), the lateral plantar artery shared in the supply of the most proximal part of the muscle. These results can be useful in determining the appropriate flap design based on the abductor hallucis type of insertion and the pattern of its arterial supply in the patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The intricate spatial and energy distribution of magnetic fields, self-generated during high power laser irradiation (at Iλ2∼1013-1014W.cm-2.μm2) of a solid target, and of the heat-carrying electron currents, is studied in inertial confinement fusion (ICF) relevant conditions. This is done by comparing proton radiography measurements of the fields to an improved magnetohydrodynamic description that fully takes into account the nonlocality of the heat transport. We show that, in these conditions, magnetic fields are rapidly advected radially along the target surface and compressed over long time scales into the dense parts of the target. As a consequence, the electrons are weakly magnetized in most parts of the plasma flow, and we observe a reemergence of nonlocality which is a crucial effect for a correct description of the energetics of ICF experiments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Adverse conditions prenatally increase the risk of cardiovascular disease, including hypertension. Chronic hypoxia in utero (CHU) causes endothelial dysfunction, but whether sympathetic vasoconstrictor nerve functioning is altered is unknown. We, therefore, compared in male CHU and control (N) rats muscle sympathetic nerve activity, vascular sympathetic innervation density, and mechanisms of sympathetic vasoconstriction. In young (Y)-CHU and Y-N rats (≈3 months), baseline arterial blood pressure was similar. However, tonic muscle sympathetic nerve activity recorded focally from arterial vessels of spinotrapezius muscle had higher mean frequency in Y-CHU than in Y-N rats (0.56±0.075 versus 0.33±0.036 Hz), and the proportions of single units with high instantaneous frequencies (1–5 and 6–10 Hz) being greater in Y-CHU rats. Sympathetic innervation density of tibial arteries was ≈50% greater in Y-CHU than in Y-N rats. Increases in femoral vascular resistance evoked by sympathetic stimulation at low frequency (2 Hz for 2 minutes) and bursts at 20 Hz were substantially smaller in Y-CHU than in Y-N rats. In Y-N only, the neuropeptide Y Y1-receptor antagonist BIBP3226 attenuated these responses. By contrast, baseline arterial blood pressure was higher in middle-aged (M)-CHU than in M-N rats (≈9 months; 139±3 versus 126±3 mmHg, respectively). BIBP3226 had no effect on femoral vascular resistance increases evoked by 2 Hz or 20 Hz bursts in M-N or M-CHU rats. These results indicate that fetal programming induced by prenatal hypoxia causes an increase in centrally generated muscle sympathetic nerve activity in youth and hypertension by middle age. This is associated with blunting of sympathetically evoked vasoconstriction and its neuropeptide Y component that may reflect premature vascular aging and contribute to increased risk of cardiovascular disease

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dental Panoramic Tomography (DPT) is a widely used and valuable examination in dentistry. One area prone to artefacts and therefore misinterpretation is the anterior region of the mandible. This case study discusses a periapical radiolucency related to lower anterior teeth that is discovered to be a radiographic artefact. Possible causes of the artefact include a pronounced depression in the mental region of the mandible or superimposition of intervertebral spaces. Additional limitations of the DPT image include superimposition of radio-opaque structures, reduced image detail compared to intra-oral views and uneven magnification. These problems often make the DPT inappropriate for imaging the anterior mandible.

CLINICAL RELEVANCE: Panoramic radiography is often unsuitable for radiographic examination of the anterior mandible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: We have been developing an image-guided single vocal cord irradiation technique to treat patients with stage T1a glottic carcinoma. In the present study, we compared the dose coverage to the affected vocal cord and the dose delivered to the organs at risk using conventional, intensity-modulated radiotherapy (IMRT) coplanar, and IMRT non-coplanar techniques.

METHODS AND MATERIALS: For 10 patients, conventional treatment plans using two laterally opposed wedged 6-MV photon beams were calculated in XiO (Elekta-CMS treatment planning system). An in-house IMRT/beam angle optimization algorithm was used to obtain the coplanar and non-coplanar optimized beam angles. Using these angles, the IMRT plans were generated in Monaco (IMRT treatment planning system, Elekta-CMS) with the implemented Monte Carlo dose calculation algorithm. The organs at risk included the contralateral vocal cord, arytenoids, swallowing muscles, carotid arteries, and spinal cord. The prescription dose was 66 Gy in 33 fractions.

RESULTS: For the conventional plans and coplanar and non-coplanar IMRT plans, the population-averaged mean dose ± standard deviation to the planning target volume was 67 ± 1 Gy. The contralateral vocal cord dose was reduced from 66 ± 1 Gy in the conventional plans to 39 ± 8 Gy and 36 ± 6 Gy in the coplanar and non-coplanar IMRT plans, respectively. IMRT consistently reduced the doses to the other organs at risk.

CONCLUSIONS: Single vocal cord irradiation with IMRT resulted in good target coverage and provided significant sparing of the critical structures. This has the potential to improve the quality-of-life outcomes after RT and maintain the same local control rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The identification of pre-clinical microvascular damage in hypertension by non-invasive techniques has proved frustrating for clinicians. This proof of concept study investigated whether entropy, a novel summary measure for characterizing blood velocity waveforms, is altered in participants with hypertension and may therefore be useful in risk stratification.

Methods: Doppler ultrasound waveforms were obtained from the carotid and retrobulbar circulation in 42 participants with uncomplicated grade 1 hypertension (mean systolic/diastolic blood pressure (BP) 142/92 mmHg), and 26 healthy controls (mean systolic/diastolic BP 116/69 mmHg). Mean wavelet entropy was derived from flow-velocity data and compared with traditional haemodynamic measures of microvascular function, namely the resistive and pulsatility indices.

Results: Entropy, was significantly higher in control participants in the central retinal artery (CRA) (differential mean 0.11 (standard error 0.05 cms(-1)), CI 0.009 to 0.219, p 0.017) and ophthalmic artery (0.12 (0.05), CI 0.004 to 0.215, p 0.04). In comparison, the resistive index (0.12 (0.05), CI 0.005 to 0.226, p 0.029) and pulsatility index (0.96 (0.38), CI 0.19 to 1.72, p 0.015) showed significant differences between groups in the CRA alone. Regression analysis indicated that entropy was significantly influenced by age and systolic blood pressure (r values 0.4-0.6). None of the measures were significantly altered in the larger conduit vessel.

Conclusion: This is the first application of entropy to human blood velocity waveform analysis and shows that this new technique has the ability to discriminate health from early hypertensive disease, thereby promoting the early identification of cardiovascular disease in a young hypertensive population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: To assess quantitatively variations in the extent of capillary basement membrane (BM) thickening between different retinal layers and within arterial and venous environments during diabetes.

METHODS: One year after induction of experimental (streptozotocin) diabetes in rats, six diabetic animals together with six age-matched control animals were sacrificed and the retinas fixed for transmission electron microscopy (TEM). Blocks of retina straddling the major arteries and veins in the central retinal were dissected out, embedded in resin, and sectioned. Capillaries in close proximity to arteries or veins were designated as residing in either an arterial (AE) or a venous (VE) environment respectively, and the retinal layer in which each capillary was located was also noted. The thickness of the BM was then measured on an image analyser based two dimensional morphometric analysis system.

RESULTS: In both diabetics and controls the AE capillaries had consistently thicker BMs than the VE capillaries. The BMs of both AE and VE capillaries from diabetics were thicker than those of capillaries in the corresponding retinal layer from the normal rats (p < or = 0.005). Also, in normal AE and VE capillaries and diabetic AE capillaries the BM in the nerve fibre layer (NFL) was thicker than that in either the inner (IPL) or outer (OPL) plexiform layers (p < or = 0.001). However, in diabetic VE capillaries the BMs of capillaries in the NFL were thicker than those of capillaries in the IPL (p < or = 0.05) which, in turn, had thicker BMs than capillaries in the OPL (p < or = 0.005).

CONCLUSIONS: The variation in the extent of capillary BM thickening between different retinal layers within AE and VE environments may be related to differences in levels of oxygen tension and oxidative stress in the retina around arteries compared with that around veins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Belfast city center is fractured, divided by motorways, parking lots, empty buildings, and big box stores. Its 19th-century heyday put it on the international map of textile production, which transformed and enriched its built structure. This tight architectural fabric was slowly destroyed in the 1940s by the Blitz, in the 1970s by road plans and “the troubles” and in the 1990s by large retail buildings. Few pedestrian streets traverse Belfast, and among them, most are recently-developed conduits for the passage of shoppers from one chain store to the next.Within this seemingly bleak urban landscape, there remain a few areas that offer a richer, more architecturally and socially diverse, more memory-laden conception of public space. Current redevelopment plans, however, threaten the mere existence of these few remaining historic streets in Belfast.This reality inspired the current project of one of the Masters in Architecture design units at Queen’s University Belfast. Our team (led by urban designer Michael Corr and myself) has been exploring North Street, one of the main arteries in Belfast City Center. Although North Street has a reputation for being run-down, derelict, and in need of redevelopment, it is one of the few intact 19th-century streets left in the area, and as such is worthy of study as an example of public space that is not strictly synonymous with commercial space.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wavelet entropy assesses the degree of order or disorder in signals and presents this complex information in a simple metric. Relative wavelet entropy assesses the similarity between the spectral distributions of two signals, again in a simple metric. Wavelet entropy is therefore potentially a very attractive tool for waveform analysis. The ability of this method to track the effects of pharmacologic modulation of vascular function on Doppler blood velocity waveforms was assessed. Waveforms were captured from ophthalmic arteries of 10 healthy subjects at baseline, after the administration of glyceryl trinitrate (GTN) and after two doses of N(G)-nitro-L-arginine-methyl ester (L-NAME) to produce vasodilation and vasoconstriction, respectively. Wavelet entropy had a tendency to decrease from baseline in response to GTN, but significantly increased after the administration of L-NAME (mean: 1.60 ± 0.07 after 0.25 mg/kg and 1.72 ± 0.13 after 0.5 mg/kg vs. 1.50 ± 0.10 at baseline, p < 0.05). Relative wavelet entropy had a spectral distribution from increasing doses of L-NAME comparable to baseline, 0.07 ± 0.04 and 0.08 ± 0.03, respectively, whereas GTN had the most dissimilar spectral distribution compared with baseline (0.17 ± 0.08, p = 0.002). Wavelet entropy can detect subtle changes in Doppler blood velocity waveform structure in response to nitric-oxide-mediated changes in arteriolar smooth muscle tone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulsed beams of energetic x-rays and neutrons from intense laser interactions with solid foils are promising for applications where bright, small emission area sources, capable of multi-modal delivery are ideal. Possible end users of laser-driven multi-modal sources are those requiring advanced non-destructive inspection techniques in industry sectors of high value commerce such as aerospace, nuclear and advanced manufacturing. We report on experimental work that demonstrates multi-modal operation of high power laser-solid interactions for neutron and x-ray beam generation. Measurements and Monte Carlo radiation transport simulations show that neutron yield is increased by a factor ∼2 when a 1 mm copper foil is placed behind a 2 mm lithium foil, compared to using a 2 cm block of lithium only. We explore x-ray generation with a 10 picosecond drive pulse in order to tailor the spectral content for radiography with medium density alloy metals. The impact of using >1 ps pulse duration on laser-accelerated electron beam generation and transport is discussed alongside the optimisation of subsequent bremsstrahlung emission in thin, high atomic number target foils. X-ray spectra are deconvolved from spectrometer measurements and simulation data generated using the GEANT4 Monte Carlo code. We also demonstrate the unique capability of laser-driven x-rays in being able to deliver single pulse high spatial resolution projection imaging of thick metallic objects. Active detector radiographic imaging of industrially relevant sample objects with a 10 ps drive pulse is presented for the first time, demonstrating that features of 200 μm size are resolved when projected at high magnification.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The basics of laser driven neutron sources, properties and possible applications are discussed. We describe the laser driven nuclear processes which trigger neutron generation, namely, nuclear reactions induced by laser driven ion beam (ion n), thermonuclear fusion by implosion and photo-induced nuclear (gamma n) reactions. Based on their main properties, i.e. point source (< 100 μm) and short durations (< ns), different applications are described, such as radiography, time-resolved spectroscopy and pump-probe experiments. Prospects on the development of laser technology suggest that, as higher intensities and higher repetition rate lasers become available (for example, using DPSSL technology), laser driven methodologies may provide neutron fluxes comparable to that achieved by accelerator driven neutron sources in the near future.