128 resultados para Ames assay


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The means to detect the irradiation of food has been investigated for many years. In recent times radiolytic products, termed 2-alkylcyclobutanones (2-CBs), have been identified as excellent markers of irradiation in lipid-containing foods. An ELISA test was developed, which was capable of detecting a number of these compounds in irradiated chicken meat. A polyclonal antiserum was raised to a 2-CB containing a terminal carboxyl group conjugated to a carrier protein. This antiserum was highly specific for cyclobutanones containing C-10 and C-12 side chains. During assay validation the limit of detection of the assay was calculated to be 0.064 pg of 2-CB per gram of fat, within- and between-assay variations ranged from 6.7 to 18%. During experimental studies, chicken meat irradiated at doses ranging from 2.5 to 10 kGy were assayed and correctly identified as being treated. Quantitative comparisons between the ELISA and CC-MS revealed a good correlation (r(2) = 0.913) between the two methodologies in concentrations of 2-CB detected in irradiated samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A radioreceptor assay was developed for the determination of the p-blocker carazolol in porcine muscle and kidney. The method involves a simple alkaline extraction procedure using diethyl ether followed by a competitive assay between carazolol residues and [H-3]-dihydroalprenolol ([H-3]-DHA) using solubilised beta2-adrenoceptors isolated from a transfected cell line. The limit of detection (LOD) was determined using 20 reference blank samples of pig kidney and pig muscle. LODs for muscle (0.93 mug kg(-1)) and kidney (1.47 mug kg(-1)) were well below their respective European community maximum residue limits, (MRLs 5 and 25 mug kg(-1), respectively). The assay was used to investigate if carazolol residues persisted in pig tissues for up to 30 h post-intramuscular injection at the recommended dose rate (10 mug carazolol/kg body weight). The highest mean +/- S.D. concentrations were detected at 1 h post-injection in kidney (10.84 +/- 1.3 mug kg(-1)) and muscle (3.59 +/- 0.2 mug kg(-1)) which were less than the respective MRLs. It is concluded that this method offers a robust and rapid alternative to other methods for the screening of carazolol residues in pig meat. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biosensor-based immunochemical screening assays for the detection of sulfadiazine (SDZ) and sulfamethazine (SMT) in muscle extract from pigs were developed. Samples were extracted with aqueous buffer and then centrifuged. This simple and straightforward preparation allowed up to 40 samples to be processed and analysed in 1 d. The limits of detection for the assays were found to be 5.6 ng g(-1) for SDZ and 7.4 ng g(-1) for SMT. These figures were well below the European and US legal limits for sulfonamides (100 ng g(-1)). The precision (RSD) between runs was

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Techniques for screening porcine samples for antimicrobial residues in the EU usually involve analysis of samples taken post slaughter, and are either time consuming or expensive. Some of the positive test results at this screening stage could be avoided by allowing the animal sufficient withdrawal time following drug treatment. A method is described that can detect the presence of five major antibiotics in porcine urine at concentrations below 1 mu g ml(-1) for each of the compounds. The test uses Bacillus subtilis, which is already widely employed in antimicrobial inhibition assays, and when combined with a colorimetric substrate, p-nitrophenyl-beta-D-glucopyranoside, can detect inhibitory substances within an assay time of four and a half hours. The method, which uses microtitre plate technology, could be developed into a convenient test kit for use at farm level to determine whether animals were still excreting antimicrobials in their urine prior to their submission for slaughter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A liquid chromatography-thermospray mass spectrometric assay was developed and validated to confirm the presence of illegal residues of the synthetic androgenic growth promoter, trenbolone acetate, in cattle. The assay was specific for 17alpha-trenbolone, the major bovine metabolite of trenbolone acetate. Methods were developed for the determination of 17alpha-trenbolone in both bile and faeces, the most appropriate matrices for the control of trenbolone acetate abuse. The clean-up.procedure developed relied on enzymatic hydrolysis, followed by sequential liquid-liquid and liquid-solid extraction. The extracts were then subjected to immunoaffinity chromatography. 17alpha-Trenbolone was detected by selected ion monitoring at m/z 271 using positive ion thermospray ionisation. The limit of detection was approximately 0.5 ng/g in faeces and 0.5 ng/ml in bile.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pantothenicacid (PA), vitamin B5, is an essential B vitamin that may be fortified in food and as such requires robust and accurate methods of detection to meet compliance legislation. This study reports the production and characterisation of the first monoclonalantibody (MAb) specific for PA and the subsequent development of a surface plasmon resonance (SPR) biosensorassay for the quantification of PA. The developed assay was compared with an SPR based commercial kit which utilised a polyclonal antibody (PAb). Foodstuffs, including cereals (n = 43), infant formulas and baby food (n = 10) and fruit juices (n = 48) were analysed by both the MAb and PAb biosensorassays and comparison plots showed good correlation (R2 0.77–0.99). The results indicate that the MAb basedbiosensorassay is suitable for the measurement of PA in foodstuffs and has the added advantage of facilitating a constant, long term supply of identical antibody. Preliminary matrix studies suggest the MAb basedassay is an excellent candidate for further validation studies and routine quality assurance based analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study the design and development of two real-time PCR assays for the rapid, sensitive and specific detection of infectious laryngotracheitis virus (ILTV) DNA is described. A Primer-Probe Energy Transfer (PriProET) assay and 5' conjugated Minor Groove Binder (MGB) method are compared and contrasted. Both have been designed to target the thymidine kinase gene of the ILTV genome. Both PriProET and MGB assays are capable of detecting 20 copies of a DNA standard per reaction and are linear from 2 x 10(8) to 2 x 10(2) copies/mu l. Neither PriProET, nor MGB reacted with heterologous herpesviruses, indicating a high specificity of the two methods as novel tools for virus detection and identification. This study demonstrates the suitability of PriProET and 5' conjugated MGB probes as real-time PCR chemistries for the diagnosis of respiratory diseases caused by ILTV. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel assay for the pan-serotypic detection of foot-and-mouth disease virus (FMDV) was designed using a 5' conjugated minor groove binder (MGB) probe real-time RT-PCR system. This assay targets the 3D region of the FMDV genome and is capable of detecting 20 copies of a transcribed RNA standard. The linear range of the test was eight logs from 2 x 10(1) to 2 x 10(8) copies and amplification time was approximately 2 h. Using a panel of 83 RNA samples from representative FMDV isolates, the diagnostic sensitivity of this test was shown to be equivalent to a TaqMan real-time RT-PCR that targets the 5' untranslated region of FMDV. Furthermore, the assay does not detect viruses causing similar clinical diseases in pigs such as swine vesicular disease virus and vesicular stomatitis virus, nor does it detect marine caliciviruses causing vesicular exanthema. The development of this assay provides a useful tool for the differential diagnosis of FMD, potentially for use in statutory or emergency testing programmes, or for detection of FMDV RNA in research applications. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design and development of a 5' conjugated minor groove binder (MGB) probe real-time RT-PCR assay are described for rapid, sensitive and specific detection of swine vesicular disease virus (SVDV) RNA. The assay is designed to target the 2C gene of the SVDV genome and is capable of detecting 2 x 10(2) copies of an RNA standard per reaction. It does not detect any of the other RNA viruses that cause vesicular disease in pigs, or the human enterovirus, Coxsackie B5 virus (CVB5) which is closely related antigenically to SVDV. The linear range of this test was from 2 x 10(2) to 2 x 10(8) copies/mu l. The assay is rapid and can detect SVDV RNA in just over 3.5 h including the time required for nucleic acid extraction. The development of this assay provides a useful tool for the differential diagnosis of SVD or for the detection of SVDV in research applications. This study demonstrates the suitability of MGB probes as a real-time PCR chemistry for the diagnosis of swine vesicular disease. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Burkholderia cenocepacia is a multidrug-resistant opportunistic pathogen that infects the airways of patients with cystic fibrosis (CF) and can survive intracellularly in macrophages and epithelial cells. The gentamicin protection assay, which relies on the poor ability of gentamicin or other aminoglycosides to permeate eukaryotic cell membranes, is traditionally employed to quantify intracellular bacteria. However, the high resistance of these bacteria to aminoglycosides hampers the use of the gentamicin protection assay to investigate intracellular infection by B. cenocepacia. Here, we report the construction of gentamicin-sensitive strains of B. cenocepacia carrying a deletion of the BCAL1674, BCAL1675, and BCAL1676 genes that form an operon encoding an AmrAB-OprA-like efflux pump. We show that bacteria carrying this deletion are hypersensitive to gentamicin and also delay phagolysosomal fusion upon infection of RAW 264.7 murine macrophages, as previously demonstrated for the parental strain. We also demonstrate for the first time that low concentrations of gentamicin can be used to effectively kill extracellular bacteria and reliably quantify the intracellular infection by B. cenocepacia, which can replicate in RAW 264.7 macrophages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A replica plate screening technique, based on the acid molybdate assay for detection of phosphate has been developed to permit the detection of microorganisms capable of mineralizing organophosphonates. The method was further adapted as the basis of an activity stain for the detection of the carbon - phosphorus bond cleavage enzyme phosphonoacetate hydrolase in PAGE gels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A heterologous competitive indirect enzyme-linked immunosorbent assay (ciELISA) for the determination of the furaltadone metabolite 3-amino-5-morpholinomethyl-2-oxazolidinone (AMOZ) was developed. AMOZ was derivatised with 2-(4-formylphenoxy) acetic acid or 2-(3-formylphenoxy) acetic acid to obtain two novel immunizing haptens. The ability of these haptens in producing specific polyclonal antibodies against the nitrophenyl derivative of AMOZ (NPAMOZ) was compared with that of traditional immunizing haptens (derivatised AMOZ with 3-carboxybenzaldehyle or 4-carboxybenzaldehyle). The results indicated that the novel immunizing haptens were able to produce antibodies with almost a two-fold improvement in sensitivity of the ciELISA for NPAMOZ in comparison with the existing antibody based ELISAs. The differences in sensitivity were explained by the molecular modeling of the lowest energy conformations of NPAMOZ and the haptens. Another novel hapten, derivatised AMOZ with 2-oxoacetic acid, was synthesized and used as a heterologous coating hapten. The results showed that this strategy of using only a partial structure of the target molecule as the coating hapten was able to obtain a two to three-fold improvement in sensitivity. This study provided a modern approach for the development of an immunoassay with improved sensitivity for the metabolites of nitrofuran antibiotics. © 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A surface plasmon resonance (SPR)-based inhibition assay method using a polyclonal anti-mouse IgM arrayed Cryptosporidium sensor chip was developed for the real-time detection of Cryptosporidium parvum oocysts. The Cryptosporidium sensor chip was fabricated by subsequent immobilization of streptavidin and polyclonal anti-mouse IgM (secondary antibody) onto heterogeneous self-assembled monolayers (SAMs). The assay consisted of the immunoreaction step between monoclonal anti-C. parvum oocyst (primary antibody) and oocysts, followed by the binding step of the unbound primary antibody onto the secondary antibody surface. It enhanced not only the immunoreaction yield of the oocysts by batch reaction but also the accessibility of analytes to the chip surface by antibody–antibody interaction. Furthermore, the use of optimum concentration of the primary antibody maximized its binding response on the chip. An inversely linear calibration curve for the oocyst concentration versus SPR signal was obtained in the range of 1×106–1×102 oocysts ml-1. The oocyst detection was also successfully achieved in natural water systems. These results indicate that the SPR-based inhibition assay using the Cryptosporidium sensor chip has high application potential for the real-time analysis of C. parvum oocyst in laboratory and field water monitoring.