83 resultados para 290603 Membrane and Separation Technologies
Resumo:
A La0.6Sr0.4Co0.2F0.8O3 mixed ionic electronic conducting (MIEC) membrane was used in a dual chamber reactor for the promotion of the catalytic activity of a platinum catalyst for ethylene oxidation. By controlling the oxygen chemical potential difference across the membrane, a driving force for oxygen ions to migrate across the membrane and backspillover onto the catalyst surface is established. The reaction is then promoted by the formation of a double layer of oxide anions on the catalyst surface. Thelectronic conductivity of the membrane material eliminates the need for an external circuit to pump the promoting oxide ion species through the membrane and onto the catalyst surface. This renders this "wireless" system simpler and more amenable for large-scale practical application. Preliminary experiments show that the reaction rate of ethylene oxidation can indeed be promoted by almost one order of magnitude upon exposure to an oxygen atmosphere on the sweep side of the membrane reactor, and thus inducing an oxygen chemical potential difference across the membrane, as compared to the rate under an inert sweep gas. Moreover, the rate does not return to its initial unpromoted value upon cessation of the oxygen flow on the sweep side, but remains permanently promoted. A number of comparisons are drawn between the classical electrochemical promotion that utilises an external circuit and the "wireless" system that utilises chemical potential differences. In addition a 'surface oxygen capture' model is proposed to explain the permanent promotion of the catalyst activity. © 2007 Springer Science+Business Media, LLC.
Resumo:
The effect of different pressure levels (500 and 600. MPa for 1. min at ambient temperature) on lasagne ready meal as a means of increasing the safety and shelf life during storage at refrigeration (4. °C) and abuse temperature (8. °C) was investigated. High-pressure processing (500 and 600. MPa for 1. min) was able to significantly reduce the total aerobic and lactic acid bacteria counts and prolong the microbiological shelf life of lasagne at both refrigeration and abuse temperatures. Pressure at 600. MPa was a useful tool to reduce the safety risks associated with Staphylococcus aureus and Listeria monocytogenes. However, abuse storage temperature facilitated the recovery of L. monocytogenes towards the end of storage. Organoleptic evaluation revealed that HPP did not negatively influence the quality attributes of lasagne and prolonged its organoleptic shelf life. HPP treatment can serve as a useful additional step to enhance safety and increase the shelf life of multicomponent ready meals, such as lasagne. Industrial relevance: The ready meals sector of the food industry has been experiencing increasing growth in the past years. This comprehensive study explored the effects of HPP on a very popular multicomponent ready meal i.e., lasagne after treatment and during storage. The results showed that HPP can be successfully applied to lasagne ready meals to decrease the risk from S. aureus and L. monocytogenes and also significantly prolong its shelf life without affecting its organoleptic properties. The utilisation of HPP by the industry can significantly increase safety and also provide the opportunity for this product to reach markets further away.
Resumo:
Paramedics are trained to use specialized medical knowledge and a variety of medical procedures and pharmaceutical interventions to “save patients and prevent further damage” in emergency situations, both as members of “health-care teams” in hospital emergency departments (Swanson, 2005: 96) and on the streets – unstandardized contexts “rife with chaotic, dangerous, and often uncontrollable elements” (Campeau, 2008: 3). The paramedic’s unique skill-set and ability to function in diverse situations have resulted in the occupation becoming ever more important to health care systems (Alberta Health and Wellness, 2008: 12).
Today, prehospital emergency services, while varying, exist in every major city and many rural areas throughout North America (Paramedics Association of Canada, 2008) and other countries around the world (Roudsari et al., 2007). Services in North America, for instance, treat and/or transport 2 million Canadians (over 250,000 in Alberta alone ) and between 25 and 30 million Americans annually (Emergency Medical Services Chiefs of Canada, 2006; National EMS Research Agenda, 2001). In Canada, paramedics make up one of the largest groups of health care professionals, with numbers exceeding 20,000 (Pike and Gibbons, 2008; Paramedics Association of Canada, 2008). However, there is little known about the work practices of paramedics, especially in light of recent changes to how their work is organized, making the profession “rich with unexplored opportunities for research on the full range of paramedic work” (Campeau, 2008: 2).
This presentation reports on findings from an institutional ethnography that explored the work of paramedics and different technologies of knowledge and governance that intersect with and organize their work practices. More specifically, my tentative focus of this presentation is on discussing some of the ruling discourses central to many of the technologies used on the front lines of EMS in Alberta and the consequences of such governance practices for both the front line workers and their patients. In doing so, I will demonstrate how IE can be used to answer Rankin and Campbell’s (2006) call for additional research into “the social organization of information in health care and attention to the (often unintended) ways ‘such textual products may accomplish…ruling purposes but otherwise fail people and, moreover, obscure that failure’ (p. 182)” (cited in McCoy, 2008: 709).
Resumo:
Prostate cancer is the second most common cause of cancer-associated deaths in men and signalling via a transcription factor called androgen receptor (AR) is an important driver of the disease. Androgen treatment is known to affect the expression and activity of other oncogenes including receptor tyrosine kinases (RTKs). In this study we report that AR-positive prostate cancer cell-lines express 50% higher levels of enzymes in the hexosamine biosynthesis pathway (HBP) than AR-negative prostate cell-lines. HBP produces hexosamines that are used by endoplasmic reticulum and golgi enzymes to glycosylate proteins targeted to plasma-membrane and secretion. Inhibition of O-linked glycosylation by ST045849 or N-linked glycosylation with tunicamycin decreased cell viability by 20%. In addition, tunicamycin inhibited the androgen-induced expression of AR target genes KLK3 and CaMKK2 by 50%. RTKs have been shown to enhance AR activity and we used an antibody array to identify changes in the phosphorylation status of RTKs in response to androgen stimulation. Hormone treatment increased the activity of Insulin like Growth Factor 1-Receptor (IGF-1R) ten-fold and this was associated with a concomitant increase in the N-linked glycosylation of the receptor, analyzed by lectin enrichment experiments. Glycosylation is known to be important for the processing and stability of RTKs. Inhibition of N-linked glycosylation resulted in accumulation of IGF-1R pro-receptor with altered mobility as shown by immunoprecipitation. Confocal imaging revealed that androgen induced plasma-membrane localization of IGF-1R was blocked by tunicamycin. In conclusion we have established that the glycosylation of IGF-1R is necessary for the full activation of the receptor in response to androgen treatment and that perturbing this process can break the feedback loop between AR and IGF-1R activation in prostate cells. Achieving similar results selectively in a clinical setting will be an important challenge in the future.
Resumo:
Efficient synaptic vesicle membrane recycling is one of the key factors required to sustain neurotransmission. We investigated potential differences in the compensatory endocytic machineries in two glutamatergic synapses with phasic and tonic patterns of activity in the lamprey spinal cord. Post-embedding immunocytochemistry demonstrated that proteins involved in synaptic vesicle recycling, including dynamin, intersectin, and synapsin, occur at higher levels (labeling per vesicle) in tonic dorsal column synapses than in phasic reticulospinal synapses. Synaptic vesicle protein 2 occurred at similar levels in the two types of synapse. After challenging the synapses with high potassium stimulation for 30 min the vesicle pool in the tonic synapse was maintained at a normal level, while that in the phasic synapse was partly depleted along with expansion of the plasma membrane and accumulation of clathrin-coated intermediates at the periactive zone. Thus, our results indicate that an increased efficiency of the endocytic machinery in a synapse may be one of the factors underlying the ability to sustain neurotransmission at high rates.
Resumo:
High-pressure processing (HPP) can produce tomato juice of high quality and safety with a short shelf life under refrigeration temperatures. Long-term higher temperature storage studies are rare and temperature tolerant products are challenging to develop. The effect of high-pressure processing (HPP) on the total quality (colour, microbial counts, phytochemical levels, antioxidant and enzymatic activities) and stability (retention over time) of tomato juice during long-term storage was investigated. Thermal processing (TP) was used as a control treatment, and overall, two different ambient conditions (20 °C and 28 °C) were tested. Immediately after processing, HPP products proved superior to TP ones (enhanced redness, total carotenoids and lycopene, stable total phenols and inactivation of pectin methyl esterase). During initial storage (30 d) most quality attributes of HPP juice remained stable. Prolonged storage, however, led to losses of most quality attributes, although HPP (20 °C) showed lower quality degradation rate constants comparison to TP and HPP (28 °C). Industrial Relevance: There is a demand for ambient stable tomato products, especially in some parts of the world, and current industrial practices (canning, pasteurisation) either compromise in product quality or require refrigeration conditions. High-pressure processing has been investigated as milder technology, with a potential to deliver superior quality. The drawback is that is also requires chill storage. The results of this study show how quality parameters behave in a high-pressured tomato product and pave the way for further development that could optimise this technology. This could be of economic importance for the tomato juice industry to develop new products stable in ambient temperatures and perhaps beneficial for cutting down the refrigeration costs under specific conditions.
Resumo:
PURPOSE:
To assess the noneconomic value of tests used in the diagnosis and management of glaucoma, and explore the contexts and factors that determine such value.
DESIGN:
Perspective.
METHODS:
Selected articles from primary and secondary sources were reviewed and interpreted in the context of the authors' clinical and research experience, influenced by our perspectives on the tasks of reducing the global problem of irreversible blindness caused by glaucoma. The value of any test used in glaucoma is addressed by 3 questions regarding: its contexts, its kind of value, and its implicit or explicit benefits.
RESULTS:
Tonometry, slit-lamp gonioscopy, and optic disc evaluation remain the foundation of clinic-based case finding, whether in areas of more or less abundant resources. In resource-poor areas, there is urgency in identifying patients at risk for severe functional loss of vision; screening strategies have proven ineffective, and efforts are hindered by the inadequate allocation of support. In resource-abundant areas, the wider spectrum of glaucoma is addressed, with emphasis on early detection of structural changes of little functional consequence; these are increasingly the focus of new and expensive technologies whose clinical value has not been established in longitudinal and population-based studies. These contrasting realities in part reflect differences among the value ascribed, often implicitly, to the tests used in glaucoma.
CONCLUSIONS:
The value of any test is determined by 3 aspects: its context of usage; its comparative worth and to whom its benefit accrues; and how we define historically what we are testing. These multiple factors
Resumo:
A relatively simple, selective, precise and accurate high performance liquid chromatography (HPLC) method based on a reaction of phenylisothiocyanate (PITC) with glucosamine (GL) in alkaline media was developed and validated to determine glucosamine hydrochloride permeating through human skin in vitro. It is usually problematic to develop an accurate assay for chemicals traversing skin because the excellent barrier properties of the tissue ensure that only low amounts of the material pass through the membrane and skin components may leach out of the tissue to interfere with the analysis. In addition, in the case of glucosamine hydrochloride, chemical instability adds further complexity to assay development. The assay, utilising the PITC-GL reaction was refined by optimizing the reaction temperature, reaction time and PITC concentration. The reaction produces a phenylthiocarbamyl-glucosamine (PTC-GL) adduct which was separated on a reverse-phase (RP) column packed with 5 microm ODS (C18) Hypersil particles using a diode array detector (DAD) at 245 nm. The mobile phase was methanol-water-glacial acetic acid (10:89.96:0.04 v/v/v, pH 3.5) delivered to the column at 1 ml min-1 and the column temperature was maintained at 30 degrees C. Galactosamine hydrochloride (Gal-HCl) was used as an internal standard. Using a saturated aqueous solution of glucosamine hydrochloride, in vitro permeation studies were performed at 32+/-1 degrees C over 48 h using human epidermal membranes prepared by a heat separation method and mounted in Franz-type diffusion cells with a diffusional area 2.15+/-0.1 cm2. The optimum derivatisation reaction conditions for reaction temperature, reaction time and PITC concentration were found to be 80 degrees C, 30 min and 1% v/v, respectively. PTC-Gal and GL adducts eluted at 8.9 and 9.7 min, respectively. The detector response was found to be linear in the concentration range 0-1000 microg ml-1. The assay was robust with intra- and inter-day precisions (described as a percentage of relative standard deviation, %R.S.D.) <12. Intra- and inter-day accuracy (as a percentage of the relative error, %RE) was <or=-5.60 and <or=-8.00, respectively. Using this assay, it was found that GL-HCl permeates through human skin with a flux 1.497+/-0.42 microg cm-2 h-1, a permeability coefficient of 5.66+/-1.6x10(-6) cm h-1 and with a lag time of 10.9+/-4.6 h.