100 resultados para 228
Resumo:
One of the difficulties with using molecularly imprinted polymers (MIPs) and other electrically insulating materials as the recognition element in electrochemical sensors is the lack of a direct path for the conduction of electrons from the active sites to the electrode. We have sought to address this problem through the preparation and characterization of novel hybrid materials combining a catalytic MIP, capable of oxidizing the template, catechol, with an electrically conducting polymer. In this way a network of "molecular wires" assists in the conduction of electrons from the active sites within the MIP to the electrode surface. This was made possible by the design of a new monomer that combines orthogonal polymerizable functionality; comprising an aniline group and a methacrylamide. Conducting films were prepared on the surface of electrodes (Au on glass) by electropolymerization of the aniline moiety. A layer of MIP was photochemically grafted over the polyaniline, via N,N'-diethyldithiocarbamic acid benzyl ester (iniferter) activation of the methacrylamide groups. Detection of catechol by the hybrid-MIP sensor was found to be specific, and catechol oxidation was detected by cyclic voltammetry at the optimized operating conditions: potential range -0.6 V to +0.8 V (vs Ag/AgCl), scan rate 50 mV/s, PBS pH 7.4. The calibration curve for catechol was found to be linear to 144 µM, with a limit of detection of 228 nM. Catechol and dopamine were detected by the sensor, whereas analogues and potentially interfering compounds, including phenol, resorcinol, hydroquinone, serotonin, and ascorbic acid, had minimal effect (=3%) on the detection of either analyte. Nonimprinted hybrid electrodes and bare gold electrodes failed to give any response to catechol at concentrations below 0.5 mM. Finally, the catalytic properties of the sensor were characterized by chronoamperometry and were found to be consistent with Michaelis-Menten kinetics. © 2009 American Chemical Society.
Resumo:
The research reports on a survey of 228 blind and partially sighted persons in 15 health authorities across Scotland. The survey reports data on patient experience of receiving health information in accessible reading formats. Data indicated that about 90% of blind and partially sighted persons did not receive communications from various NHS health departments in a format that they could read by themselves. The implications for patient privacy, confidentiality and wider impact on life and health care are highlighted. The implications for professional ethical medical practice and for public policy are also discussed. Recommendations for improved practice are made.
Resumo:
A sensitive and rapid method was developed for angiotensin-converting enzyme (ACE) activity determination by capillary zone electrophoresis. Hippuryl-View the MathML source-histidyl-View the MathML source-leucine, a synthetic tripeptide, was used as the ACE-specific substrate. Capillary zone electrophoresis was employed to separate the products of the enzymatic reaction and the ACE activity was determined by quantification of hippuric acid, a result of the enzymatic reaction on the tripeptide. The capillary electrophoresis was performed in a 27 cm × 75 μm i.d. fused-silica capillary using 200 mM boric acid–borate buffer (pH 9.0) as a run buffer with an applied voltage of 8.1 kV at a capillary temperature of 23°C. The electrophoresis was monitored at 228 nm. Each electrophoretic run requires only a nanoliter of the enzymatic reactant solution, at only 6 min, rendering a powerful tool for the ACE assay.
Resumo:
BACKGROUND: PET/CT scanning can determine suitability for curative therapy and inform decision making when considering radical therapy in patients with non-small cell lung cancer (NSCLC). Metastases to central mediastinal lymph nodes (N2) may alter such management decisions. We report a 2 year retrospective series assessing N2 lymph node staging accuracy with PET/CT compared to pathological analysis at surgery.
METHODS: Patients with NSCLC attending our centre (excluding those who had induction chemotherapy) who had staging PET/CT scans and pathological nodal sampling between June 2006 and June 2008 were analysed. For each lymph node assessed pathologically, the corresponding PET/CT status was determined. 64 patients with 200 N2 lymph nodes were analysed.
RESULTS: Sensitivity of PET/CT scans for indentifying involved N2 lymph nodes was
39%, specificity 96% and overall accuracy 90%. For individual lymph node analysis, logistic regression demonstrated a significant linear association between PET/CT sensitivity and time from scanning to surgery (p=0.031) but not for specificity and accuracy. Those scanned <9 weeks before pathological sampling were significantly more sensitive (64% >9 weeks, 0% ≥ 9 weeks, p=0.013) and more accurate (94% <9 weeks, 81% ≥ 9 weeks, p=0.007). Differences in specificity were not seen (97% <9 weeks, 91% ≥ 9 weeks, p=0.228). No significant difference in specificity was found at any time point.
CONCLUSIONS: We recommend that if a PET/CT scan is older than 9 weeks, and management would be altered by the presence of N2 nodes, re-staging of the
mediastinum should be undertaken.
Resumo:
Il D.Lgs. 150/09 ha inteso dar vita ad una “riforma organica” della PA italiana, improntandone il funzionamento a logiche di programmazione e controllo delle performance. Attorno a tale concetto la riforma ha costruito un Sistema teso a programmare, misurare, controllare, valutare e comunicare la performance degli enti. Il lavoro si focalizza sulla programmazione, e in particolare sullo strumento cardine introdotto dal D.Lgs. 150/09: il Piano della Performance (PdP). Il contributo, basato su una metodologia deduttivo-induttiva, si concentra sui comuni medi italiani, scelti in quanto statisticamente rappresentativi del livello medio di complessità degli enti locali. Sono stati oggetto di indagine i PdP pubblicati sui siti istituzionali degli enti considerati, al fine di verificarne sia il livello di aderenza alle Linee Guida (LG) emanate dalla Commissione Indipendente per la Valutazione, la Trasparenza e l’Integrità delle amministrazioni pubbliche (CIVIT) e dalla Associazione Nazionale Comuni Italiani (ANCI), sia il loro livello di adeguatezza economico-aziendale. Preliminarmente si indagherà il tema della programmazione, sotto il profilo normativo-dottrinale, concentrandosi su soggetti, processi e strumenti. Poi si sposterà il focus sul PdP: dopo aver definito obiettivi, quesiti e metodologia della ricerca, verranno esplicitate le configurazioni di PdP emergenti dalle LG CIVIT e ANCI. Verranno poi illustrati i risultati della ricerca empirica, mettendo in luce il livello di allineamento dei PdP dei comuni medi alle LG, nonché il livello di adeguatezza economico-aziendale degli stessi. Si tratteggeranno quindi alcune brevi conclusioni.
Resumo:
This paper presents the background rationale and key findings for a model-based study of supercritical waste heat recovery organic Rankine cycles. The paper’s objective is to cover the necessary groundwork to facilitate the future operation of a thermodynamic organic Rankine cycle model under realistic thermodynamic boundary conditions for performance optimisation of organic Rankine cycles. This involves determining the type of power cycle for organic Rankine cycles, the circuit configuration and suitable boundary conditions. The study focuses on multiple heat sources from vehicles but the findings are generally applicable, with careful consideration, to any waste heat recovery system. This paper introduces waste heat recovery and discusses the general merits of organic fluids versus water and supercritical operation versus subcritical operation from a theoretical perspective and, where possible, from a practical perspective. The benefits of regeneration are investigated from an efficiency perspective for selected subcritical and supercritical conditions. A simulation model is described with an introduction to some general Rankine cycle boundary conditions. The paper describes the analysis of real hybrid vehicle data from several driving cycles and its manipulation to represent the thermal inertia for model heat input boundary conditions. Basic theory suggests that selecting the operating pressures and temperatures to maximise the Rankine cycle performance is relatively straightforward. However, it was found that this may not be the case for an organic Rankine cycle operating in a vehicle. When operating in a driving cycle, the available heat and its quality can vary with the power output and between heat sources. For example, the available coolant heat does not vary much with the load, whereas the quantity and quality of the exhaust heat varies considerably. The key objective for operation in the vehicle is optimum utilisation of the available heat by delivering the maximum work out. The fluid selection process and the presentation and analysis of the final results of the simulation work on organic Rankine cycles are the subjects of two future publications.
Resumo:
This article proposes a closed-loop control scheme based on joint-angle feedback for cable-driven parallel manipulators (CDPMs), which is able to overcome various difficulties resulting from the flexible nature of the driven cables to achieve higher control accuracy. By introducing a unique structure design that accommodates built-in encoders in passive joints, the seven degrees of freedom (7-DOF) CDPM can obtain joint angle values without external sensing devices, and it is used for feedback control together with a proper closed-loop control algorithm. The control algorithm has been derived from the time differential of the kinematic formulation, which relates the joint angular velocities to the time derivative of cable lengths. In addition, the Lyapunov stability theory and Monte Carlo method have been used to mathematically verify the self-feedback control law that has tolerance for parameter errors. With the aid of co-simulation technique, the self-feedback closed-loop control is applied on a 7-DOF CDPM and it shows higher motion accuracy than the one with an open-loop control. The trajectory tracking experiment on the motion control of the 7-DOF CDPM demonstrated a good performance of the self-feedback control method.
Resumo:
The majority of the kinetic models employed in catalytic after-treatment of exhaust emissions use a global kinetic approach owing to the simplicity because one expression can account for all the steps in a reaction. The major drawback of this approach is the limited predictive capabilities of the models. The intrinsic kinetic approach offers much more information about the processes occurring within the catalytic converter; however, it is significantly more complex and time consuming to develop. In the present work, a methodology which allows accessing a model that combines the simplicity of the global kinetic approach and the accuracy of the intrinsic kinetic approach is reported. To assess the performance of this new approach, the oxidation of carbon monoxide in the presence of nitric oxide as well as a driving cycle was investigated. The modelling of carbon monoxide oxidation with oxygen which utilised the intrinsic kinetic approach with the global kinetic approach was used for the carbon monoxide + nitric oxide reaction (and all remaining reactions for the driving cycle). The comparison of the model results for the dual intrinsic + global kinetic approach with the experimental data obtained for both the reactor and the driving cycle indicate that the dual approach is promising with results significantly better than those obtained with only the global kinetics approach.
Resumo:
BACKGROUND: The 'frequent exacerbator' is recognised as an important phenotype in COPD. Current understanding about this phenotype comes from prospective longitudinal clinical trials in secondary/tertiary care with little information reported in primary care populations.
AIMS: To characterize the frequent-exacerbator phenotype and identify associated risk factors in a large UK primary care COPD population.
METHODS: Using a large database of primary care patients from 80 UK general practices, patients were categorised using GOLD 2014 criteria into high and low risk groups based on exacerbation history. A multivariate logistic regression model was used to investigate covariates associated with the frequent-exacerbator phenotype and risk of experiencing a severe exacerbation (leading to hospitalisation).
RESULTS: Of the total study population (n = 9219), 2612 (28%) fulfilled the criteria for high risk frequent-exacerbators. Independent risk factors (adjusted odds ratio [95% CI]) for ≥2 exacerbations were: most severely impaired modified Medical Research Council (mMRC) dyspnoea score (mMRC grade 4: 4.37 [2.64-7.23]), lower FEV1 percent predicted (FEV1 <30%: 2.42 [1.61-3.65]), co-morbid cardiovascular disease (1.42 [1.19-1.68]), depression (1.56 [1.22-1.99]) or osteoporosis (1.54 [1.19-2.01]), and female gender (1.20 [1.01-1.43]). Older patients (≥75 years), those with most severe lung impairment (FEV1 <30%), those with highest mMRC score and those with co-morbid osteoporosis were identified as most at risk of experiencing exacerbations requiring hospitalisation.
CONCLUSIONS: Although COPD exacerbations occur across all grades of disease severity, female patients with high dyspnoea scores, more severely impaired lung function and co-morbidities are at greatest risk. Elderly patients, with severely impaired lung function, high mMRC scores and osteoporosis are associated with experience of severe exacerbations requiring hospitalisation.
Resumo:
This paper presents a novel real-time power-device temperature estimation method that monitors the power MOSFET's junction temperature shift arising from thermal aging effects and incorporates the updated electrothermal models of power modules into digital controllers. Currently, the real-time estimator is emerging as an important tool for active control of device junction temperature as well as online health monitoring for power electronic systems, but its thermal model fails to address the device's ongoing degradation. Because of a mismatch of coefficients of thermal expansion between layers of power devices, repetitive thermal cycling will cause cracks, voids, and even delamination within the device components, particularly in the solder and thermal grease layers. Consequently, the thermal resistance of power devices will increase, making it possible to use thermal resistance (and junction temperature) as key indicators for condition monitoring and control purposes. In this paper, the predicted device temperature via threshold voltage measurements is compared with the real-time estimated ones, and the difference is attributed to the aging of the device. The thermal models in digital controllers are frequently updated to correct the shift caused by thermal aging effects. Experimental results on three power MOSFETs confirm that the proposed methodologies are effective to incorporate the thermal aging effects in the power-device temperature estimator with good accuracy. The developed adaptive technologies can be applied to other power devices such as IGBTs and SiC MOSFETs, and have significant economic implications.
Resumo:
In the immediate aftermath of the Second World War, only those who had opposed the Germans or were perceived to have done so could freely express themselves. Soon, however, three young writers clearly leaning to the right of the political spectrum – Antoine Blondin, Roger Nimier and Jacques Laurent – dared to challenge their narratives in a series of provocative novels published between 1949 and 1954. Quickly referred to as the Hussards after the publication in 1952 of a famous essay by Bernard Frank, these writers momentarily occupied the literary space left vacant by their older peers. Without denying the provocative, political and subversive dimensions of the Hussards’ war novels, this article will argue that their success was mainly due to the fact that they were largely in line – and not in contradiction – with the ‘horizon of expectations’ of their time (Jauss, 1982).
Resumo:
Novel egg-laying boards were found to be effective in the biological control of the freshwater fish louse Argulus foliaceus in a 12.9 ha rainbow trout Oncorhynchus mykiss fishery which had a high prevalence and intensity of infection of juvenile parasites in the early spring of 1999. Approximately 228 000d during an extensive 14 week period of egg laying which peaked in June 1999. In contrast, only 1566 clutches were harvested in 2000, when egg laying activity showed a bi-modal distribution, peaking in May and again in July and August. iaceus on rainbow trout in consecutive years was 2.9 : 1 and 2.1 : 1. Estimates of the size of the female A. foliaceus population based on egg-laying activity in 1999 exceeded that derived from measurements of prevalence and intensity of infection, whereas in 2000, this was more in balance. A minimum temperature of 10 degree C was identified for egg laying, which occurred continuously from May to October in a broadly synchronous manner.. Copyright 2002 The Fisheries Society of the British Isles
Resumo:
Fermentation products can chaotropically disorder macromolecular systems and induce oxidative stress, thus inhibiting biofuel production. Recently, the chaotropic activities of ethanol, butanol and vanillin have been quantified (5.93, 37.4, 174kJkg(-1)m(-1) respectively). Use of low temperatures and/or stabilizing (kosmotropic) substances, and other approaches, can reduce, neutralize or circumvent product-chaotropicity. However, there may be limits to the alcohol concentrations that cells can tolerate; e.g. for ethanol tolerance in the most robust Saccharomyces cerevisiae strains, these are close to both the solubility limit (<25%, w/v ethanol) and the water-activity limit of the most xerotolerant strains (0.880). Nevertheless, knowledge-based strategies to mitigate or neutralize chaotropicity could lead to major improvements in rates of product formation and yields, and also therefore in the economics of biofuel production.
Resumo:
This paper details the theory and implementation of a composite damage model, addressing damage within a ply (intralaminar) and delamination (interlaminar), for the simulation of crushing of laminated composite structures. It includes a more accurate determination of the characteristic length to achieve mesh objectivity in capturing intralaminar damage consisting of matrix cracking and fibre failure, a load-history dependent material response, an isotropic hardening nonlinear matrix response, as well as a more physically-based interactive matrix-dominated damage mechanism. The developed damage model requires a set of material parameters obtained from a combination of standard and non-standard material characterisation tests. The fidelity of the model mitigates the need to manipulate, or "calibrate", the input data to achieve good agreement with experimental results. The intralaminar damage model was implemented as a VUMAT subroutine, and used in conjunction with an existing interlaminar damage model, in Abaqus/Explicit. This approach was validated through the simulation of the crushing of a cross-ply composite tube with a tulip-shaped trigger, loaded in uniaxial compression. Despite the complexity of the chosen geometry, excellent correlation was achieved with experimental results.
Resumo:
The discovery of two superluminous supernovae at large distances from Earth pushes the frontier of supernova studies to just 1.5 billion years after the Big Bang, and suggests that they may be common in the young Universe. See Letter p.228