90 resultados para wide area based information embedded power system (IEPS-W)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

While load flow conditions vary with different loads, the small-signal stability of the entire system is closely related with to the locations, capacities and models of loads. In this paper, load impacts with different capacities and models on the small-signal stability are analysed. In the real large-scale power system case, the load sensitivity which denotes the sensitivity of the eigenvalue with respect to the load active power is introduced and applied to rank the loads. The loads with high sensitivity are also considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The increased interconnectivity and complexity of supervisory control and data acquisition (SCADA) systems in power system networks has exposed the systems to a multitude of potential vulnerabilities. In this paper, we present a novel approach for a next-generation SCADA-specific intrusion detection system (IDS). The proposed system analyzes multiple attributes in order to provide a comprehensive solution that is able to mitigate varied cyber-attack threats. The multiattribute IDS comprises a heterogeneous white list and behavior-based concept in order to make SCADA cybersystems more secure. This paper also proposes a multilayer cyber-security framework based on IDS for protecting SCADA cybersecurity in smart grids without compromising the availability of normal data. In addition, this paper presents a SCADA-specific cybersecurity testbed to investigate simulated attacks, which has been used in this paper to validate the proposed approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anti-islanding protection is becoming increasingly important due to the rapid installation of distributed generation from renewable resources like wind, tidal and wave, solar PV, bio-fuels, as well as from other resources like diesel. Unintentional islanding presents a potential risk for damaging utility plants and equipment connected from the demand side, as well as to public and personnel in utility plants. This paper investigates automatic islanding detection. This is achieved by deploying a statistical process control approach for fault detection with the real-time data acquired through a wide area measurement system, which is based on Phasor Measurement Unit (PMU) technology. In particular, the principal component analysis (PCA) is used to project the data into principal component subspace and residual space, and two statistics are used to detect the occurrence of fault. Then a fault reconstruction method is used to identify the fault and its development over time. The proposed scheme has been used in a real system and the results have confirmed that the proposed method can correctly identify the fault and islanding site.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Smart Grids are characterized by the application of information communication technology (ICT) to solve electrical energy challenges. Electric power networks span large geographical areas, thus a necessary component of many Smart Grid applications is a wide area network (WAN). For the Smart Grid to be successful, utilities must be confident that the communications infrastructure is secure. This paper describes how a WAN can be deployed using WiMAX radio technology to provide high bandwidth communications to areas not commonly served by utility communications, such as generators embedded in the distribution network. A planning exercise is described, using Northern Ireland as a case study. The suitability of the technology for real-time applications is assessed using experimentally obtained latency data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, our previous work on Principal Component Analysis (PCA) based fault detection method is extended to the dynamic monitoring and detection of loss-of-main in power systems using wide-area synchrophasor measurements. In the previous work, a static PCA model was built and verified to be capable of detecting and extracting system faulty events; however the false alarm rate is high. To address this problem, this paper uses a well-known ‘time lag shift’ method to include dynamic behavior of the PCA model based on the synchronized measurements from Phasor Measurement Units (PMU), which is named as the Dynamic Principal Component Analysis (DPCA). Compared with the static PCA approach as well as the traditional passive mechanisms of loss-of-main detection, the proposed DPCA procedure describes how the synchrophasors are linearly
auto- and cross-correlated, based on conducting the singular value decomposition on the augmented time lagged synchrophasor matrix. Similar to the static PCA method, two statistics, namely T2 and Q with confidence limits are calculated to form intuitive charts for engineers or operators to monitor the loss-of-main situation in real time. The effectiveness of the proposed methodology is evaluated on the loss-of-main monitoring of a real system, where the historic data are recorded from PMUs installed in several locations in the UK/Ireland power system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The advantages of high energy efficiency and economic benefit promote the wide application of combined heat and power system (CHP) based microgrid. Firstly, a mathematical model of the CHP based microgrid is developed. Then, a cost function for the coordination of heat and electric load is proposed. Finally, an optimal dispatch model is developed to achieve the economical and coordinated operation of the CHP based microgrid system. Simulation results verify effectiveness of the proposed dispatch model, which is a powerful tool for the energy management of CHP based microgrid with renewable energy resources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Synchrophasors have become an important part of the modern power system and numerous applications have been developed covering wide-area monitoring, protection and control. Most applications demand continuous transmission of synchrophasor data across large geographical areas and require an efficient communication framework. IEEE C37.118-2 evolved as one of the most successful synchrophasor communication standards and is widely adopted. However, it lacks a predefined security mechanism and is highly vulnerable to cyber attacks. This paper analyzes different types of cyber attacks on IEEE C37.118-2 communication system and evaluates their possible impact on any developed synchrophasor application. Further, the paper also recommends an efficent security mechanism that can provide strong protection against cyber attacks. Although, IEEE C37.118-2 has been widely adopted, there is no clear understanding of the requirements and limitations. To this aim, the paper also presents detailed performance evaluation of IEEE C37.118-2 implementations which could help determine required resources and network characteristics before designing any synchrophasor application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to the variability and stochastic nature of wind power system, accurate wind power forecasting has an important role in developing reliable and economic power system operation and control strategies. As wind variability is stochastic, Gaussian Process regression has recently been introduced to capture the randomness of wind energy. However, the disadvantages of Gaussian Process regression include its computation complexity and incapability to adapt to time varying time-series systems. A variant Gaussian Process for time series forecasting is introduced in this study to address these issues. This new method is shown to be capable of reducing computational complexity and increasing prediction accuracy. It is further proved that the forecasting result converges as the number of available data approaches innite. Further, a teaching learning based optimization (TLBO) method is used to train the model and to accelerate
the learning rate. The proposed modelling and optimization method is applied to forecast both the wind power generation of Ireland and that from a single wind farm to show the eectiveness of the proposed method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A graphical method is presented for determining the capability of individual system nodes to accommodate wind power generation. The method is based upon constructing a capability chart for each node at which a wind farm is to be connected. The capability chart defines the domain of allowable power injections at the candidate node, subject to constraints imposed by voltage limits, voltage stability and equipment capability limits being satisfied. The chart is first derived for a two-bus model, before being extended to a multi-node power system. The graphical method is employed to derive the chart for a two-node system, as well as its application to a multi-node power system, considering the IEEE 30-bus test system as a case study. Although the proposed method is derived with the intention of determining the wind farm capacity to be connected at a specific node, it can be used for the analysis of a PQ bus loading as well as generation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Porous carbon aerogels are prepared by polycondensation of resorcinol (R) and formaldehyde (F)catalyzed by sodium carbonate (C) followed by carbonization of the resultant aerogels at 800? in an inert atmosphere. The porous texture of the carbons has been adjusted by the change of the molar ratio of resorcinol to catalyst (R/C) in the gel precursors in the range of 100 to 500. The porous structure of the aerogels and carbon aerogels are characterized by N2 adsorption-desorption measurements at 77 K. It is found that total pore volume and average pore diameter of the carbons increase with increase in the R/C ratio of the gel precursors.The prepared carbon aerogels are used as active materials in fabrication of composite carbon electrodes. The electrochemical performance of the electrodes has been tested by using them as cathodes in a Li/O2 cell. Through the galvanostatic charge/discharge measurements, it is found that with an increase of R/C ratio, the specific capacity of the Li/O2 cell fabricated from the carbon aerogels increases from 716 to 2077 charge/discharge cycles indicate that the carbon samples possess excellent stability on cycling.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dwindling fossil fuel resources and pressures to reduce greenhouse gas emissions will result in a more diverse range of generation portfolios for future electricity systems. Irrespective of the portfolio mix the overarching requirement for all electricity suppliers and system operators is to instantaneously meet demand, to operate to standards and reduce greenhouse gas emissions. Therefore all electricity market participants will ultimately need to use a variety of tools to balance the power system. Thus the role of demand side management with energy storage will be paramount to integrate future diverse generation portfolios. Electric water heating has been studied previously, particularly at the domestic level to provide load control, peak shave and to bene?t end-users ?nancially with lower bills, particularly in vertically integrated monopolies. In this paper a number of continuous direct load control demand response based electric water heating algorithms are modelled to test the effectiveness of wholesale electricity market signals to study the system bene?ts. The results are compared and contrasted to determine which control algorithm showed the best potential for energy savings, system marginal price savings and wind integration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Turbulence characteristics in the Indonesian seas on the horizontal scale of order of 100 km were calculated with a regional model of the Indonesian seas circulation in the area based on the Princeton Ocean Model (POM). As is well known, the POM incorporates the Mellor–Yamada turbulence closure scheme. The calculated characteristics are: twice the turbulence kinetic energy per unit mass, <i>q</i><sup>2</sup>; the turbulence master scale, &ell;; mixing coefficients of momentum, <i>K</i><sub>M</sub>; and temperature and salinity, <i>K</i><sub>H</sub>; etc. The analyzed turbulence has been generated essentially by the shear of large-scale ocean currents and by the large-scale wind turbulence. We focused on the analysis of turbulence around important topographic features, such as the Lifamatola Sill, the North Sangihe Ridge, the Dewakang Sill, and the North and South Halmahera Sea Sills. In general, the structure of turbulence characteristics in these regions turned out to be similar. For this reason, we have carried out a detailed analysis of the Lifamatola Sill region because dynamically this region is very important and some estimates of mixing coefficients in this area are available. <br><br> Briefly, the main results are as follows. The distribution of <i>q</i><sup>2</sup> is quite adequately reproduced by the model. To the north of the Lifamatola Sill (in the Maluku Sea) and to the south of the Sill (in the Seram Sea), large values of <i>q</i><sup>2</sup> occur in the deep layer extending several hundred meters above the bottom. The observed increase of <i>q</i><sup>2</sup> near the very bottom is probably due to the increase of velocity shear and the corresponding shear production of <i>q</i><sup>2</sup> very close to the bottom. The turbulence master scale, &ell;, was found to be constant in the main depth of the ocean, while &ell; rapidly decreases close to the bottom, as one would expect. However, in deep profiles away from the sill, the effect of topography results in the &ell; structure being unreasonably complicated as one moves towards the bottom. Values of 15 to 20 × 10<sup>&minus;4</sup> m<sup>2</sup> s<sup>-1</sup> were obtained for <i>K</i><sub>M</sub> and <i>K</i><sub>H</sub> in deep water in the vicinity of the Lifamatola Sill. These estimates agree well with basin-scale averaged values of 13.3 × 10<sup>&minus;4</sup> m<sup>2</sup> s<sup>-1</sup> found diagnostically for <i>K</i><sub>H</sub> in the deep Banda and Seram Seas (Gordon et al., 2003) and a value of 9.0 × 10<sup>&minus;4</sup> m<sup>2</sup> s<sup>-1</sup> found diagnostically for <i>K</i><sub>H</sub> for the deep Banda Sea system (van Aken et al., 1988). The somewhat higher simulated values can be explained by the presence of steep topography around the sill.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: One way to tackle health inequalities in resource-poor settings is to establish links between doctors and health professionals there and specialists elsewhere using web-based telemedicine. One such system run by the Swinfen Charitable Trust has been in existence for 13 years which is an unusually long time for such systems.

Objective: We wanted to gain some insights into whether and how this system might be improved.

Methods: We carried out a survey by questionnaire of referrers and specialists over a six months period.

Results: During the study period, a total of 111 cases were referred from 35 different practitioners, of whom 24% were not doctors. Survey replies were received concerning 67 cases, a response rate of 61 per cent. Eighty-seven per cent of the responding referrers found the telemedicine advice useful, and 78% were able to follow the advice provided. As a result of the advice received, the diagnosis was changed in 22% of all cases and confirmed in a further 18 per cent. Patient management was changed in 33 per cent. There was no substantial difference between doctors and non-doctors. During the study period, the 111 cases were responded to by 148 specialists, from whom 108 replies to the questionnaire were received, a response rate of 73 per cent. About half of the specialists (47%) felt that their advice had improved the management of the patients. There were 62 cases where it was possible to match up the opinions of the referrer and the consultants about the value of a specific teleconsultation. In 34 cases (55%) the referrers and specialists agreed about the value. However, in 28 cases (45%) they did not: specialists markedly underestimated the value of a consultation compared to referrers. Both referrers and specialist were extremely positive about the system which appears to be working well. Minor changes such as a clearer referral template and an improved web interface for specialists may improve it.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A micro-grid is an autonomous system which can be operated and connected to an external system or isolated with the help of energy storage systems (ESSs). While the daily output of distributed generators (DGs) strongly depends on the temporal distribution of natural resources such as wind and solar, unregulated electric vehicle (EV) charging demand will deteriorate the imbalance between the daily load and generation curves. In this paper, a statistical model is presented to describe daily EV charging/discharging behaviour. An optimisation problem is proposed to obtain economic operation for the micro-grid based on this model. In day-ahead scheduling, with estimated information of power generation and load demand, optimal charging/discharging of EVs during 24 hours is obtained. A series of numerical optimization solutions in different scenarios is achieved by serial quadratic programming. The results show that optimal charging/discharging of EVs, a daily load curve can better track the generation curve and the network loss and required ESS capacity are both decreased. The paper also demonstrates cost benefits for EVs and operators.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper considers the enhancement of loss-of-mains detection by use of a differential rate-of-change-of-frequency relay to reduce nuisance tripping and improve sensitivity to small excursions in frequency. The telecommunications media which might carry the differential ROCOF signal are reviewed with a focus on channel latency, bandwidth and security.