67 resultados para time-dependent behaviour of brittle rocks
Resumo:
Triclabendazole (TCBZ), the anthelmintic drug active against both mature and immature liver flukes, was used to investigate the effect of in vivo treatment on the tegumental surface of juvenile Fasciola gigantica. Five goats were infected with 150 F. gigantica metacercariae each by oral gavage. Four of them were treated with single dose of TCBZ at 10mg/kg at four weeks post-infection. They were euthanized at 0 (untreated), 24, 48, 72 and 96h post treatment. Juvenile flukes were manually retrieved from the goat livers and processed for scanning electron microscopy. In control flukes, the anterior region was adorned with sharply pointed spines projecting away from the surface, while in the posterior region, spines become shorter and narrower, loosing serration and with the appearance of distinct furrows and papillae. The dorsal surface retained the same pattern of surface architecture similar to that of ventral surface. Flukes obtained from 24h post-treatment did not show any apparent change and were still very active. However, there were limited movements and some blebbing, swelling, deposition of tegumental secretions and some flattening displayed by the flukes of 48h post-treatment. All the worms were found dead 72h post-treatment and showed advanced level of tegumental disruptions, consisting of severe distortion of spines, sloughing off the tegument to expose the basal lamina, formation of pores and isolated patches of lesions. By 96h post-treatment, the disruption was extremely severe and the tegument was completely sheared off causing deeper lesions that exposed the underlying musculature. The disruption was more severe at posterior than anterior region and on ventral than dorsal surface. The present study further establishes the time-course of TCBZ action in vivo with 100% efficacy against the juvenile tropical liver fluke.
Resumo:
Molecular dynamics (MD) simulation was carried out to acquire an in-depth understanding of the flow behaviour of single crystal silicon during nanometric cutting on three principal crystallographic planes and at different cutting temperatures. The key findings were that (i) the substrate material underneath the cutting tool was observed for the first time to experience a rotational flow akin to fluids at all the tested temperatures up to 1200 K. (ii) The degree of flow in terms of vorticity was found higher on the (1 1 1) crystal plane signifying better machinability on this orientation in accord with the current pool of knowledge (iii) an increase in the machining temperature reduces the springback effect and thereby the elastic recovery and (iv) the cutting orientation and the cutting temperature showed significant dependence on the location of the stagnation region in the cutting zone of the substrate.
Resumo:
We investigate electron dynamics in the hydrogen atom and the hydrogen molecular ion when exposed to long wavelength laser pulses yet having intensity insufficient to ionize the system. We find that the field is still able to drive the electron, leading to time-dependent interference effects.
Resumo:
Spectroscopic studies of line emission intensities and ratios offer an attractive option in the\r\ndevelopment of non-invasive plasma diagnostics. Evaluating ratios of selected He I line\r\nemission profiles from the singlet and triplet neutral helium spin systems allows for simultaneous\r\nmeasurement of electron density (ne) and temperature (Te) profiles. Typically, this powerful\r\ndiagnostic tool is limited by the relatively long relaxation times of the 3S metastable term of helium\r\nthat populates the triplet spin system, and on which electron temperature sensitive lines are based.\r\nBy developing a time dependent analytical solution, we model the time evolution of the two spin\r\nsystems. We present a hybrid time dependent/independent line ratio solution that improves the\r\nrange of application of this diagnostic technique in the scrape-off layer (SOL) and edge plasma\r\nregions when comparing it against the current equilibrium line ratio helium model used at\r\nTEXTOR.
Resumo:
We review the development of the time-dependent close-coupling method to study atomic and molecular few body dynamics. Applications include electron and photon collisions with atoms, molecules, and their ions.
Resumo:
In the presence of a (time-dependent) macroscopic electric field the electron dynamics of dielectrics cannot be described by the time-dependent density only. We present a real-time formalism that has the density and the macroscopic polarization P as key quantities. We show that a simple local function of P already captures long-range correlation in linear and nonlinear optical response functions. Specifically, after detailing the numerical implementation, we examine the optical absorption, the second- and third-harmonic generation of bulk Si, GaAs, AlAs and CdTe at different level of approximation. We highlight links with ultranonlocal exchange-correlation functional approximations proposed within linear response time-dependent density functional theory framework.
Resumo:
Corrosion fatigue is a fracture process as a consequence of synergistic interactions between the material structure, corrosive environment and cyclic loads/strains. It is difficult to be detected and can cause unexpected failure of engineering components in use. This study reveals a comparison of corrosion fatigue behaviour of laser-welded and bare NiTi wires using bending rotation fatigue (BRF) test coupled with a specifically-designed corrosion cell. The testing medium was Hanks’ solution (simulated body fluid) at 37.5 oC. Electrochemical impedance spectroscopic (EIS) measurement was carried out to monitor the change of corrosion resistance of sample during the BRF test at different periods of time. Experiments indicate that the laser-welded NiTi wire would be more susceptible to the corrosion fatigue attack than the bare NiTi wire. This study can serve as a benchmark for the product designers and engineers to understand the corrosion fatigue behaviour of the NiTi laser weld joint and determine the fatigue life safety factor for NiTi medical devices/implants involving laser welding in the fabrication process.