87 resultados para terminally ill


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Mechanical ventilation is a critical component of paediatric intensive care therapy. It is indicated when the patient’s spontaneous ventilation is inadequate to sustain life. Weaning is the gradual reduction of ventilatory support and the transfer of respiratory control back to the patient. Weaning may represent a large proportion of the ventilatory period. Prolonged ventilation is associated with significant morbidity, hospital cost, psychosocial and physical risks to the child and even death. Timely and effective weaning may reduce the duration of mechanical ventilation and may reduce the morbidity and mortality associated with prolonged ventilation. However, no consensus has been reached on criteria that can be used to identify when patients are ready to wean or the best way to achieve it.Objectives:To assess the effects of weaning by protocol on invasively ventilated critically ill children. To compare the total duration of invasive mechanical ventilation of critically ill children who are weaned using protocols versus those weaned through usual (non-protocolized) practice. To ascertain any differences between protocolized weaning and usual care in terms of mortality, adverse events, intensive care unit length of stay and quality of life.Search methods:We searched the Cochrane Central Register of Controlled Trials (CENTRAL; The Cochrane Library, Issue 10, 2012), MEDLINE (1966 to October 2012), EMBASE (1988 to October 2012), CINAHL (1982 to October 2012), ISI Web of Science and LILACS. We identified unpublished data in the Web of Science (1990 to October 2012), ISI Conference Proceedings (1990 to October 2012) and Cambridge Scientific Abstracts (earliest to October 2012). We contacted first authors of studies included in the review to obtain further information on unpublished studies or work in progress. We searched reference lists of all identified studies and review papers for further relevant studies. We applied no language or publication restrictions.Selection criteriaWe included randomized controlled trials comparing protocolized weaning (professional-led or computer-driven) versus non-protocolized weaning practice conducted in children older than 28 days and younger than 18 years.Data collection and analysis:Two review authors independently scanned titles and abstracts identified by electronic searching. Three review authors retrieved and evaluated full-text versions of potentially relevant studies, independently extracted data and assessed risk of bias.Main results:We included three trials at low risk of bias with 321 children in the analysis. Protocolized weaning significantly reduced total ventilation time in the largest trial (260 children) by a mean of 32 hours (95% confidence interval (CI) 8 to 56; P = 0.01). Two other trials (30 and 31 children, respectively) reported non-significant reductions with a mean difference of -88 hours (95% CI -228 to 52; P = 0.2) and -24 hours (95% CI -10 to 58; P = 0.06). Protocolized weaning significantly reduced weaning time in these two smaller trials for a mean reduction of 106 hours (95% CI 28 to 184; P = 0.007) and 21 hours (95% CI 9 to 32; P < 0.001). These studies reported no significant effects for duration of mechanical ventilation before weaning, paediatric intensive care unit (PICU) and hospital length of stay, PICU mortality or adverse events.Authors' conclusions:Limited evidence suggests that weaning protocols reduce the duration of mechanical ventilation, but evidence is inadequate to show whether the achievement of shorter ventilation by protocolized weaning causes children benefit or harm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rationale: Delirium is common in intensive care unit (ICU) patients and is a predictor of worse outcomes and neuroinflammation is a possible mechanism. The antiinflammatory actions of statins may reduce delirium.

Objectives: To determine whether critically ill patients receiving statin therapy had a reduced risk of delirium than those not on statins.

Methods: A prospective cohort analysis of data from consecutive ICU patients admitted to a UK mixed medical and surgical critical care unit between August 2011 and February 2012; the Confusion Assessment Method for ICU was used to determine the days each patient was assessed as being free of delirium during ICU admission.

Measurements and Main Results: Delirium-free days, daily administration of statins, and serum C-reactive protein (CRP) were recorded. Four hundred and seventy consecutive critical care patients were followed, of whom 151 patients received statins. Using randomeffects multivariable logistic regression, statin administration the previous evening was associated with the patient being assessed as free of delirium (odds ratio, 2.28; confidence interval, 1.01-5.13; P , 0.05) and with lower CRP (b = 20.52; P , 0.01) the following day. When the association between statin and being assessed as free of delirium was controlled for CRP, the effect size became nonsignificant (odds ratio, 1.56; confidence interval, 0.64-3.79; P = 0.32).

Conclusions: Ongoing statin therapy is associated with a lower daily risk of delirium in critically ill patients. An ongoing clinical trial, informed by this study, is investigating if statins are a potential therapy for delirium in the critically ill.Copyright © 2014 by the American Thoracic Society.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This is an update of a review last published in Issue 5, 2010, of The Cochrane Library. Reducing weaning time is desirable in minimizing potential complications from mechanical ventilation. Standardized weaning protocols are purported to reduce time spent on mechanical ventilation. However, evidence supporting their use in clinical practice is inconsistent. Objectives: The first objective of this review was to compare the total duration of mechanical ventilation of critically ill adults who were weaned using protocols versus usual (non-protocolized) practice.The second objective was to ascertain differences between protocolized and non-protocolized weaning in outcomes measuring weaning duration, harm (adverse events) and resource use (intensive care unit (ICU) and hospital length of stay, cost).The third objective was to explore, using subgroup analyses, variations in outcomes by type of ICU, type of protocol and approach to delivering the protocol (professional-led or computer-driven). Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library Issue 1, 2014), MEDLINE (1950 to January 2014), EMBASE (1988 to January 2014), CINAHL (1937 to January 2014), LILACS (1982 to January 2014), ISI Web of Science and ISI Conference Proceedings (1970 to February 2014), and reference lists of articles. We did not apply language restrictions. The original search was performed in January 2010 and updated in January 2014.Selection criteriaWe included randomized controlled trials (RCTs) and quasi-RCTs of protocolized weaning versus non-protocolized weaning from mechanical ventilation in critically ill adults. Data collection and analysis: Two authors independently assessed trial quality and extracted data. We performed a priori subgroup and sensitivity analyses. We contacted study authors for additional information. Main results: We included 17 trials (with 2434 patients) in this updated review. The original review included 11 trials. The total geometric mean duration of mechanical ventilation in the protocolized weaning group was on average reduced by 26% compared with the usual care group (N = 14 trials, 95% confidence interval (CI) 13% to 37%, P = 0.0002). Reductions were most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. Weaning duration was reduced by 70% (N = 8 trials, 95% CI 27% to 88%, P = 0.009); and ICU length of stay by 11% (N = 9 trials, 95% CI 3% to 19%, P = 0.01). There was significant heterogeneity among studies for total duration of mechanical ventilation (I2 = 67%, P < 0.0001) and weaning duration (I2 = 97%, P < 0.00001), which could not be explained by subgroup analyses based on type of unit or type of approach. Authors' conclusions: There is evidence of reduced duration of mechanical ventilation, weaning duration and ICU length of stay with use of standardized weaning protocols. Reductions are most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. However, significant heterogeneity among studies indicates caution in generalizing results. Some study authors suggest that organizational context may influence outcomes, however these factors were not considered in all included studies and could not be evaluated. Future trials should consider an evaluation of the process of intervention delivery to distinguish between intervention and implementation effects. There is an important need for further development and research in the neurosurgical population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IntroductionAutomated weaning systems may improve adaptation of mechanical support for a patient’s ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. Our objective was to compare mechanical ventilator weaning duration for critically ill adults and children when managed with automated systems versus non-automated strategies. Secondary objectives were to determine differences in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events.MethodsElectronic databases were searched to 30 September 2013 without language restrictions. We also searched conference proceedings; trial registration websites; and article reference lists. Two authors independently extracted data and assessed risk of bias. We combined data using random-effects modelling.ResultsWe identified 21 eligible trials totalling 1,676 participants. Pooled data from 16 trials indicated that automated systems reduced the geometric mean weaning duration by 30% (95% confidence interval (CI) 13% to 45%), with substantial heterogeneity (I2 = 87%, P <0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not with surgical populations or using other systems. Automated systems reduced ventilation duration with no heterogeneity (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of effect on mortality, hospital LOS, reintubation, self-extubation and non-invasive ventilation following extubation. Automated systems reduced prolonged mechanical ventilation and tracheostomy. Overall quality of evidence was high.ConclusionsAutomated systems may reduce weaning and ventilation duration and ICU stay. Due to substantial trial heterogeneity an adequately powered, high quality, multi-centre randomized controlled trial is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Regional differences in adult morbidity and mortality within England (i.e., north-south divide or gradient) and between England and Scotland (i.e., Scottish effect) are only partly explained by adult levels of socioeconomic status or risk factors. This suggests variation in early life, and is supported by the fetal origins and life-course literature which posits that birth outcomes and subsequent, cumulative exposures influence adult health. However, no studies have examined the north-south gradient or Scottish effect in health in the earliest years of life. The aims of the study were: i) to examine health indicators in English and Scottish children at birth and age three to establish whether regional differences exist; and ii) to establish whether observed changes in child health at age three were attributable to birth and/or early life environmental exposures. Respondents included 10,639 biological Caucasian mothers of singleton children recruited to the Millennium Cohort Study (MCS) in the year 2000. Outcome variables were: gestational age and birth weight, and height, body mass index (BMI), and externalising behavioural problems at age three. Region/country was categorised as: South (reference), Midlands, North (England), and Scotland. Respondents provided information on child, maternal, household, and socioeconomic characteristics. Results indicated no significant regional variations for gestational age or birth weight. At age three there was a north-south gradient for externalising behaviour and a north-south divide in BMI which attenuated on adjustment. However, a north-south divide in height was not fully explained by adjustment. There was also evidence of a ‘Midlands effect’, with increased likelihood of shorter stature and behaviour problems. Results showed a Scottish effect for height and BMI in the unadjusted models, and height in the adjusted model, but a decreased likelihood of behaviour problems. Findings indicated no regional differences in health at birth, but some regional variation at age three supports the cumulative life-course model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Importance: Seriously ill hospitalized patients have identified communication and decision making about goals of care as high priorities for quality improvement in end-of-life care. Interventions to improve care are more likely to succeed if tailored to existing barriers.

Objective: To determine, from the perspective of hospital-based clinicians, (1) barriers impeding communication and decision making about goals of care with seriously ill hospitalized patients and their families and (2) their own willingness and the acceptability for other clinicians to engage in this process.

Design, Setting, and Participants: Multicenter survey of medical teaching units of nurses, internal medicine residents, and staff physicians from participating units at 13 university-based hospitals from 5 Canadian provinces.

Main Outcomes and Measures: Importance of 21 barriers to goals of care discussions rated on a 7-point scale (1 = extremely unimportant; 7 = extremely important).

Results: Between September 2012 and March 2013, questionnaires were returned by 1256 of 1617 eligible clinicians, for an overall response rate of 77.7% (512 of 646 nurses [79.3%], 484 of 634 residents [76.3%], 260 of 337 staff physicians [77.2%]). The following family member-related and patient-related factors were consistently identified by all 3 clinician groups as the most important barriers to goals of care discussions: family members' or patients' difficulty accepting a poor prognosis (mean [SD] score, 5.8 [1.2] and 5.6 [1.3], respectively), family members' or patients' difficulty understanding the limitations and complications of life-sustaining treatments (5.8 [1.2] for both groups), disagreement among family members about goals of care (5.8 [1.2]), and patients' incapacity to make goals of care decisions (5.6 [1.2]). Clinicians perceived their own skills and system factors as less important barriers. Participants viewed it as acceptable for all clinician groups to engage in goals of care discussions-including a role for advance practice nurses, nurses, and social workers to initiate goals of care discussions and be a decision coach.

Conclusions and Relevance: Hospital-based clinicians perceive family member-related and patient-related factors as the most important barriers to goals of care discussions. All health care professionals were viewed as playing important roles in addressing goals of care. These findings can inform the design of future interventions to improve communication and decision making about goals of care.