82 resultados para surgical instrument
Resumo:
Title Evaluation of Multidisciplinary Delivery of Surgical Anatomy Teaching
Authors Walsh I.K., Taylor S.J., Dorman A, Boohan M.
Objectives To evaluate the efficacy of newly introduced multidisciplinary methods to deliver Surgical Anatomy teaching to undergraduate medical students.
Design and Setting Qualitative and quantitative study using questionnaires and focus groups, employing students of the perioperative and emergency medicine (POEM) module of the phase 4 undergraduate medical curriculum at Queen’s University Belfast.
Outcome Measures To determine:
(1) if multidisciplinary teaching is effective in delivering surgical anatomy teaching,
(2) student’s learning preferences regarding this teaching method.
Results The questionnaire response rate was 89% (216 of 244 students; female: male ratio 1.25) and 42 students participated in 6 focus groups. Mean questionnaire responses indicated a favourable opinion on quality assurance items and multidisciplinary teaching. 81% of students agreed that multidisciplinary teaching enhanced learning and 86% felt that this did not adversely affect interaction. A positive contribution towards POEM learning was reported for Radiology (95% of students), Anatomy (93%) and Surgery (78%). The benefits of multidisciplinary teaching were congruent for Anatomy, Radiology and Surgery with 78% of students indicating a perceived favourable association with learning. Multidisciplinary teaching was not associated with diluted interaction, with 62% of students describing interaction as sufficient. 88% of students positively ranked tutor characteristics of enthusiasm and encouragement as being strongly associated with teacher quality. Positive perception of overall quality was strongly associated with learning preferences as well as more generic quality assurance issues (80% students; alpha coefficient 0.83).
The results were supported by triangulation of the above quantitative data with qualitative data generated by the focus groups. Whilst students frequently misunderstood the meaning of “multidisciplinary teaching”, there was an appreciation of the method’s worth; students recognised and valued the relevance of Anatomy, Radiology and Surgery teaching to POEM learning. The importance of vertically integrating Anatomy into all stages of the undergraduate curriculum was especially recognised.
Reference Aarnio M, Nieminen J, Pyorala E, Lindbolm-Ylanne S. Motivating medical students to learn. 2010 Med Teach;32(4):199-204.
Resumo:
PURPOSE: Arteriovenous fistulae (AVFs) are the preferred option for vascular access, as they are associated with lower mortality in hemodialysis patients than in those patients with arteriovenous grafts (AVGs) or central venous catheters (CVCs). We sought to assess whether vascular access outcomes for surgical trainees are comparable to fully trained surgeons.
METHODS: A prospectively collected database of patients was created and information recorded regarding patient demographics, past medical history, preoperative investigations, grade of operating surgeon, type of AVF formed, primary AVF function, cumulative AVF survival and functional patency.
RESULTS: One hundred and sixty-two patients were identified as having had vascular access procedures during the 6 month study period and 143 were included in the final analysis. Secondary AVF patency was established in 123 (86%) of these AVFs and 89 (62.2%) were used for dialysis. There was no significant difference in survival of AVFs according to training status of surgeon (log rank x2 0.506 p=0.477) or type of AVF (log rank x2 0.341 p=0.559). Patency rates of successful AVFs at 1 and 2 years were 60.9% and 47.9%, respectively.
CONCLUSION: We have demonstrated in this prospective study that there are no significant differences in outcomes of primary AVFs formed by fully trained surgeons versus surgical trainees. Creation of a primary AVF represents an excellent training platform for intermediate stage surgeons across general and vascular surgical specialties.
Resumo:
This paper reports the design of a Frequency Selective Surface (FSS) which simultaneously allows transmission of 175.3 – 191.3 GHz radiation and rejection from 164 - 167 GHz with a loss <0.5 dB for TE wave polarization at 45° incidence. The state-of-the art filter consists of three air spaced perforated screens with unit cells that are composed of nested resonant slots. The FSS satisfies the stringent electromagnetic performance requirements for signal demultiplexing in the quasi-optical feed train of the Microwave Sounder (MWS) instrument which is under development for the MetOp-SG mission.
Resumo:
This paper presents a portable electrochemical instrument capable of detecting and identifying heavy metals in soil, in situ. The instrument has been developed for use in a variety of situations to facilitate contaminated land surveys, avoiding expensive and time-consuming procedures. The system uses differential pulse anodic stripping voltammetry which is a precise and sensitive analytical method with excellent limits of detection. The identification of metals is based on a statistical microprocessor-based method. The instrument is capable of detecting six different toxic metals (lead, cadmium, zinc, nickel, mercury and copper) with good sensitivity
Resumo:
Using the Rapid Oscillation in the Solar Atmosphere (ROSA) instrument at the Dunn Solar Telescope we have found that the spectra of fluctuations of the G-band (cadence 1.05 s) and Ca II K-line (cadence 4.2 s) intensities show correlated fluctuations above white noise out to frequencies beyond 300 mHz and up to 70 mHz, respectively. The noise-corrected G-band spectrum presents a scaling range (Ultra High Frequency “UHF”) for f = 25-100 mHz, with an exponent consistent with the presence of turbulent motions. The UHF power, is concentrated at the locations of magnetic bright points in the intergranular lanes, it is highly intermittent in time and characterized by a positive kurtosis κ. Combining values of G-band and K-line intensities, the UHF power, and κ, reveals two distinct “states” of the internetwork solar atmosphere. State 1, with κ ≍ 6, which includes almost all the data, is characterized by low intensities and low UHF power. State 2, with κ ≍ 3, including a very small fraction of the data, is characterized by high intensities and high UHF power. Superposed epoch analysis shows that for State 1, the K-line intensity presents 3.5 min chromospheric oscillations with maxima occurring 21 s after G-band intensity maxima implying a 150-210 km effective height difference. For State 2, the G-band and K-line intensity maxima are simultaneous, suggesting that in the highly magnetized environment sites of G-band and K-line emission may be spatially close together. Analysis of observations obtained with Hinode/SOT confirm a scaling range in the G-band spectrum up to 53 mHz also consistent with turbulent motions as well as the identification of two distinct states in terms of the H-line intensity and G-band power as functions of G-band intensity.
Resumo:
BACKGROUND: This study aims to assess the quality of various steps of manual small incision cataract surgery and predictors of quality, using video recordings.
DESIGN: This paper applies a retrospective study.
PARTICIPANTS: Fifty-two trainees participated in a hands-on small incision cataract surgery training programme at rural Chinese hospitals.
METHODS: Trainees provided one video each recorded by a tripod-mounted digital recorder after completing a one-week theoretical course and hands-on training monitored by expert trainers. Videos were graded by two different experts, using a 4-point scale developed by the International Council of Ophthalmology for each of 12 surgical steps and six global factors. Grades ranged from 2 (worst) to 5 (best), with a score of 0 if the step was performed by trainers.
MAIN OUTCOME MEASURES: Mean score for the performance of each cataract surgical step rated by trainers.
RESULTS: Videos and data were available for 49/52 trainees (94.2%, median age 38 years, 16.3% women and 77.5% completing > 50 training cases). The majority (53.1%, 26/49) had performed ≤ 50 cataract surgeries prior to training. Kappa was 0.57∼0.98 for the steps (mean 0.85). Poorest-rated steps were draping the surgical field (mean ± standard deviation = 3.27 ± 0.78), hydro-dissection (3.88 ± 1.22) and wound closure (3.92 ± 1.03), and top-rated steps were insertion of viscoelastic (4.96 ± 0.20) and anterior chamber entry (4.69 ± 0.74). In linear regression models, higher total score was associated with younger age (P = 0.015) and having performed >50 independent manual small incision cases (P = 0.039).
CONCLUSIONS: More training should be given to preoperative draping, which is poorly performed and crucial in preventing infection. Surgical experience improves ratings.© 2015 Royal Australian and New Zealand College of Ophthalmologists.
Resumo:
Purpose: To identify factors associated prospectively with increased cataract surgical rate (CSR) in rural Chinese hospitals.
Methods: Annual cataract surgical output was obtained at baseline and 24 months later from operating room records at 42 rural, county-level hospitals. Total local CSR (cases/million population/y), and proportion of CSR from hospital and local competitors were calculated from government records. Hospital administrators completed questionnaires providing demographic and professional information, and annual clinic and outreach screening volume. Independent cataract surgeons provided clinical information and videotapes of cases for grading by two masked experts using the Ophthalmology Surgical Competency Assessment Rubric (OSCAR). Uncorrected vision was recorded for 10 consecutive cataract cases at each facility, and 10 randomly-identified patients completed hospital satisfaction questionnaires. Total value of international nongovernmental development organization (INGDO) investment in the previous three years and demographic information on hospital catchment areas were obtained. Main outcome was 2-year percentage change in hospital CSR.
Results: Among the 42 hospitals (median catchment population 530,000, median hospital CSR 643), 78.6% (33/42) were receiving INGDO support. Median change in hospital CSR (interquartile range) was 33.3% (-6.25%, 72.3%). Predictors of greater increase in CSR included higher INGDO investment (P = 0.02, simple model), reducing patient dissatisfaction (P = 0.03, simple model), and more outreach patient screening (P = 0.002, simple and multiple model).
Conclusions: Outreach cataract screening was the strongest predictor of increased surgical output. Government and INGDO investment in screening may be most likely to enhance output of county hospitals, a major goal of China's Blindness Prevention Plan.
Resumo:
Key content
- Trainees face many challenges in learning the skill set required to perform laparoscopic surgery.
- The time spent in the operating room has been detrimentally impacted upon since the implementation of the European Working Time Directive. In order to address the deficit, surgical educators have looked to the benefits enjoyed in the aviation and sports industries in using simulation training.
Learning objectives
- To summarise the current understanding of the neuropsychological basis of learning a psychomotor skill.
- To clarify factors that influence the acquisition of these skills.
- To summarise how this information can be used in teaching and assessment of laparoscopic skills.
Ethical issues
- The use of virtual reality simulators may be able to form a part of the aptitude assessment in the selection process, in order to identify trainees with the desired attributes to progress into the training programmes. However, as skill improves with practice, is it ethical to exclude novices with poor initial performance assessment before allowing them the opportunities to improve?
Resumo:
Background: Poor follow-up after cataract surgery in developing countries makes assessment of operative quality uncertain. We aimed to assess two strategies to measure visual outcome: recording the visual acuity of all patients 3 or fewer days postoperatively (early postoperative assessment), and recording that of only those patients who returned for the final follow-up examination after 40 or more days without additional prompting. Methods: Each of 40 centres in ten countries in Asia, Africa, and Latin America recruited 40-120 consecutive surgical cataract patients. Operative-eye best-corrected visual acuity and uncorrected visual acuity were recorded before surgery, 3 or fewer days postoperatively, and 40 or more days postoperatively. Clinics logged whether each patient had returned for the final follow-up examination without additional prompting, had to be actively encouraged to return, or had to be examined at home. Visual outcome for each centre was defined as the proportion of patients with uncorrected visual acuity of 6/18 or better minus the proportion with uncorrected visual acuity of 6/60 or worse, and was calculated for each participating hospital with results from the early assessment of all patients and the late assessment of only those returning unprompted, with results from the final follow-up assessment for all patients used as the standard. Findings: Of 3708 participants, 3441 (93%) had final follow-up vision data recorded 40 or more days after surgery, 1831 of whom (51% of the 3581 total participants for whom mode of follow-up was recorded) had returned to the clinic without additional prompting. Visual outcome by hospital from early postoperative and final follow-up assessment for all patients were highly correlated (Spearman's rs=0·74, p<0·0001). Visual outcome from final follow-up assessment for all patients and for only those who returned without additional prompting were also highly correlated (rs=0·86, p<0·0001), even for the 17 hospitals with unprompted return rates of less than 50% (rs=0·71, p=0·002). When we divided hospitals into top 25%, middle 50%, and bottom 25% by visual outcome, classification based on final follow-up assessment for all patients was the same as that based on early postoperative assessment for 27 (68%) of 40 centres, and the same as that based on data from patients who returned without additional prompting in 31 (84%) of 37 centres. Use of glasses to optimise vision at the time of the early and late examinations did not further improve the correlations. Interpretation: Early vision assessment for all patients and follow-up assessment only for patients who return to the clinic without prompting are valid measures of operative quality in settings where follow-up is poor. Funding: ORBIS International, Fred Hollows Foundation, Helen Keller International, International Association for the Prevention of Blindness Latin American Office, Aravind Eye Care System. © 2013 Congdon et al. Open Access article distributed under the terms of CC BY.
Resumo:
OBJECTIVE:
To assess the methodologic quality of published studies of the surgical management of coexisting cataract and glaucoma.
DESIGN:
Literature review and analysis.
METHOD:
We performed a systematic search of the literature to identify all English language articles pertaining to the surgical management of coexisting cataract and glaucoma in adults. Quality assessment was performed on all randomized controlled trials, nonrandomized controlled trials, and cohort studies. Overall quality scores and scores for individual methodologic domains were based on the evaluations of two experienced investigators who independently reviewed articles using an objective quality assessment form.
MAIN OUTCOME MEASURES:
Quality in each of five domains (representativeness, bias and confounding, intervention description, outcomes and follow-up, and statistical quality and interpretation) measured as the percentage of methodologic criteria met by each study.
RESULTS:
Thirty-six randomized controlled trials and 45 other studies were evaluated. The mean quality score for the randomized, controlled clinical trials was 63% (range, 11%-88%), and for the other studies the score was 45% (range, 3%-83%). The mean domain scores were 65% for description of therapy (range, 0%-100%), 62% for statistical analysis (range, 0%-100%), 58% for representativeness (range, 0%-94%), 49% for outcomes assessment (range, 0%-83%), and 30% for bias and confounding (range, 0%-83%). Twenty-five of the studies (31%) received a score of 0% in the bias and confounding domain for not randomizing patients, not masking the observers to treatment group, and not having equivalent groups at baseline.
CONCLUSIONS:
Greater methodologic rigor and more detailed reporting of study results, particularly in the area of bias and confounding, could improve the quality of published clinical studies assessing the surgical management of coexisting cataract and glaucoma.
Resumo:
OBJECTIVE:
To assess short- and long-term control of intraocular pressure (IOP) with different surgical treatment strategies for coexisting cataract and glaucoma.
DESIGN:
Systematic literature review and analysis.
METHOD:
We performed a search of the published literature to identify all eligible articles pertaining to the surgical management of coexisting cataract and glaucoma in adults. One investigator abstracted the content of each article onto a custom-designed form. A second investigator corroborated the findings. The evidence supporting different approaches was graded by consensus as good, fair, weak, or insufficient.
MAIN OUTCOME MEASURES:
Short-term (24 hours or fewer) and long-term (more than 24 hours) IOP control.
RESULTS:
The evidence was good that long-term IOP is lowered more by combined glaucoma and cataract operations than by cataract operations alone. On average, the IOP was 3 to 4 mmHg lower in the combined groups with fewer medications required. The evidence was weak that extracapsular cataract extraction (ECCE) alone results in short-term increase in IOP and was insufficient to determine the short-term impact of phacoemulsification cataract extraction (PECE) on IOP in glaucoma patients. The evidence was weak that short-term IOP control was better with ECCE or PECE combined with an incisional glaucoma procedure compared with ECCE or PECE alone. The evidence was also weak (but consistent) that long-term IOP is lowered by 2 to 4 mmHg after ECCE or PECE. Finally, there was weak evidence that combined PECE and trabeculectomy produces slightly worse long-term IOP control than trabeculectomy alone, and there was fair evidence that the same is true for ECCE combined with trabeculectomy.
CONCLUSIONS:
There is strong evidence for better long-term control of IOP with combined glaucoma and cataract operations compared with cataract surgery alone. For other issues regarding surgical treatment strategies for cataract and glaucoma, the available evidence is limited or conflicting.