68 resultados para polymethyl methacrylate
Resumo:
A new homologous series of side-chain liquid crystal polymers, the poly[omega-(4-cyanoazobenzene-4'-oxy)alkyl methacrylate]s, have been prepared in which the length of the flexible alkyl spacer is varied from 3 to 12 methylene units. All the polymers exhibit liquid crystalline behaviour; specifically, crystal E, smectic A and nematic phases are observed. The glass transition temperatures decrease on increasing spacer length before reaching a limiting value at ca. 30 degrees C. The clearing temperatures exhibit an odd-even effect on varying the length and parity of the spacer. This is attributed to the change in the average shape of the side chain as the parity of the spacer is varied. This rationalization also accounts for the observed alternation in the entropy change associated with the clearing transition. A weak relaxation is observed theologically for several members of this polymer series at temperatures above their respective glass transition temperatures. This is attributed either to specific motions of the smectic layers or to 180 degrees reorientational jumps of the long axis of the mesogenic unit about the polymer backbone. (C) 1997 Elsevier Science Ltd. All rights reserved.
Resumo:
This paper presents a novel strategy for the prevention of ventilator-associatedpneumonia that involves coating poly(vinyl chloride, PVC) endotracheal tubes (ET) withhydrogels that may be subsequently used to entrap nebulized antimicrobial solutions. Candidatehydrogels were prepared containing a range of ratios of hydroxyethyl methacrylate (HEMA) andmethacrylic acid (MAA) from 100:0 to 70:30 using free radical polymerization and, whenrequired, simultaneous attachment to PVC was performed. The mechanical properties, glasstransition temperatures, swelling kinetics, uptake of gentamicin from an aqueous medium, andgentamicin release were characterized. Increasing the MAA content of the hydrogels significantlydecreased the ultimate tensile strength, % elongation at break, Young’s modulus, and increasedthe glass transition temperature, the swelling ratio, and gentamicin uptake. Microbial(Staphylococcus aureus and Pseudomonas aeruginosa) adherence to control (drug-free) hydrogelswas observed; however, while adherence to gentamicin-containing p(HEMA) occurred, noadherence occurred to gentamicin-containing HEMA:MAA copolymers. Antimicrobialpersistence of gentamicin-containing hydrogels was examined by determining the zone ofinhibition against each microorganism on successive days. Hydrogel composition affected the observed antimicrobial persistence,with the hydrogel composed of 70:30 HEMA:MAA exhibiting >20 days persistence against S. aureus and P. aeruginosa,respectively. To simulate clinical use, the hydrogels (coated onto PVC) were first exposed to a nebulized solution of gentamicin(4 mL, 80 mg for 20 min), and then to nebulized bacteria (4 mL ca. 1 × 109 colony forming units mL−1, 30 min). Viable bacteriawere not observed on the gentamicin-treated p(HEMA: MAA) copolymers, whereas growth was observed on gentamicin-treatedp(HEMA). In light of the excellent antimicrobial activity and physicochemical properties, p(HEMA: MAA) copolymerscomposed of ratios of 80:20 or 70:30 HEMA: MAA were identified as potentially useful coatings of endotracheal tubes to be usedin conjunction with the clinical nebulization of gentamicin and designed for the prevention of ventilator-associated pneumonia
Resumo:
Photodynamic therapy and photodynamic antimicrobial chemotherapy are widely used, but despite this, the relationships between fluence, wavelength of irradiation and singlet oxygen (1O2) production are poorly understood. To establish the relationships between these factors in medically-relevant materials, the effect of fluence on 1O2 production from a tetrakis(4-N-methylpyridyl)porphyrin (TMPyP)-incorporated 2-hydroxyethyl methacrylate: methyl methacrylate: methacrylic acid (HEMA:MMA:MAA) copolymer, a total energy of 50.48 J/cm², was applied at varying illumination power, and times. 1O2 production was characterised using anthracene-9,10-dipropionic acid, disodium salt (ADPA) using a recently described method. Using two light sources, a white LED array and a white halogen source, the LED array was found to produce less 1O2 than the halogen source when the same power (over 500-600 nm) and time conditions were applied. Importantly, it showed that the longest wavelength Q band (590 nm) is primarily responsible for 1O2 generation, and that a linear relationship exists between increasing power and time and the production of singlet oxygen.
Resumo:
Photodynamic therapy and photodynamic antimicrobial chemotherapy are widely used, but despite this, the relationships between fluence, wavelength of irradiation and singlet oxygen ((1) O2 ) production are poorly understood. To establish the relationships between these factors in medically relevant materials, the effect of fluence on (1) O2 production from a tetrakis(4-N-methylpyridyl)porphyrin (TMPyP)-incorporated 2-hydroxyethyl methacrylate: methyl methacrylate: methacrylic acid (HEMA: MMA:MAA) copolymer, a total energy of 50.48 J/cm(2) , was applied at varying illumination power, and times. (1) O2 production was characterized using anthracene-9,10-dipropionic acid, disodium salt (ADPA) using a recently described method. Using two light sources, a white LED array and a white halogen source, the LED array was found to produce less (1) O2 than the halogen source when the same power (over 500 - 600 nm) and time conditions were applied. Importantly, it showed that the longest wavelength Q band (590 nm) is primarily responsible for (1) O2 generation, and that a linear relationship exists between increasing power and time and the production of singlet oxygen.
Resumo:
We describe, for the first time, stimuli-responsive hydrogel-forming microneedle (MN) arrays that enable delivery of a clinically-relevant model drug (ibuprofen) upon application of light. MN arrays were prepared using a polymer prepared from 2-hydroxyethyl methacrylate (HEMA) and ethylene glycol dimethacrylate (EGDMA) by micromolding. The obtained MN arrays showed good mechanical properties. The system was loaded with up to 5% (w/w) ibuprofen included in a light-responsive 3,5-dimethoxybenzoin conjugate. Raman spectroscopy confirmed the presence of the conjugate inside the polymeric MN matrix. In vitro, this system was able to deliver up to three doses of 50 mg of ibuprofen upon application of an optical trigger over a prolonged period of time (up to 160 hours). This makes the system appealing as a controlled release device for prolonged periods of time. We believe that this technology has potential for use in ?on-demand? delivery of a wide range of drugs in a variety of applications relevant to enhanced patient care.
Resumo:
This study investigated and characterised transdermal permeation of bioactive agents from a topically applied Arnica montana tincture. Permeation experiments conducted over 48 h used polydimethylsiloxane (silastic) and human epidermal membranes mounted in Franz-type diffusion cells with a methanol-water (50:50 v/v) receptor fluid. A commercially available tincture of A. montana L. derived from dried Spanish flower heads was a donor solution. Further donor solutions prepared from this stock tincture concentrated the tincture constituents 1, 2 and 10 fold and its sesquiterpene lactones 10 fold. Permeants were assayed using a high-performance liquid chromatography method. Five components permeated through silastic membranes providing peaks with relative retention factors to an internal standard (santonin) of 0.28, 1.18, 1.45, 1.98 and 2.76, respectively. No permeant was detected within 12 h of applying the Arnica tincture onto human epidermal membranes. However, after 12 h, the first two of these components were detected. These were shown by Zimmermann reagent reaction to be sesquiterpene lactones and liquid chromatography/diode array detection/mass spectrometry indicated that these two permeants were 11,13-dihydrohelenalin (DH) analogues (methacrylate and tiglate esters). The same two components were also detected within 3 h of topical application of the 10-fold concentrated tincture and the concentrated sesquiterpene lactone extract.
Resumo:
Infection is an inevitable consequence of chronic urinary catheterisation, with associated problems of recurrent catheter encrustation and blockage experienced by approximately 50% of all long-term catheterised patients. In this work we have exploited, for the first time, the reported pathogen-induced elevation of urine pH as a trigger for ‘intelligent’ antimicrobial release from novel hydrogel drug delivery systems of 2-hydroxyethyl methacrylate and vinyl-functionalised nalidixic acid derivatives, developed as candidate infection-resistant urinary catheter coatings. Demonstrating up to 20-fold faster rates of drug release at pH 10, representing infected urine pH, than at pH 7, and achieving reductions of up to 96.5% in in vitro bacterial adherence, our paradigm of pH-responsive drug delivery, which requires no external manipulation, therefore represents a promising development towards the prevention of catheter-associated urinary tract infections (CAUTIs) in vivo.
Resumo:
Pulsatile, or “on-demand”, delivery systems have the capability to deliver a therapeutic molecule at the right time/site of action and in the right amount (1). Pulsatile delivery systems present multiple benefits over conventional dosage forms and provide higher patient compliance. The combination of stimuli-responsive materials with the drug delivery capabilities of hydrogel-forming MN arrays (2) opens an interesting area of research. In the present work we describe, a stimuli-responsive hydrogel-forming microneedle (MN) array that enable delivery of a clinically-relevant model drug (ibuprofen) upon application of UV radiation (Figure 1A). MN arrays were prepared using a micromolding technique using a polymer prepared from 2-hydroxyethyl methacrylate (HEMA) and ethylene glycol dimethacrylate (EGDMA) (Figure 1B). The arrays were loaded with up to 5% (w/w) ibuprofen included in a light-responsible conjugate (3,5-dimethoxybenzoin conjugate) (2). The presence of the conjugate inside the MN arrays was confirmed by Raman spectroscopy measurements. MN arrays were tested in vitro showing that they were able to deliver up to three doses of 50 mg of ibuprofen after application of an optical trigger (wavelength of 365 nm) over a long period of time (up to 160 hours) (Figure 1C and 1D). The work presented here is a probe of concept and a modified version of the system should be used as UV radiation is shown to be the major etiologic agent in the development of skin cancers. Consequently, for future applications of this technology an alternative design should be developed. Based on the previous research dealing with hydrogel forming MN arrays a suitable strategy will be to use hydrogel-forming MN arrays containing a backing layer made with the material described in this work as the drug reservoir (2). Finally, a porous layer of a material that blocks UV radiation should be included between the MN array and the drug reservoir. Therefore radiation can be applied to the system without reaching the skin surface. Therefore after modification, the system described here interesting properties as “on-demand” release system for prolonged periods of time. This technology has potential for use in “on-demand” delivery of a wide range of drugs in a variety of applications relevant to enhanced patient care.