122 resultados para pollutant removal


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe and analyse the operation and stabilization of a Mach--Zehnder interferometer, which separates the carrier and the first-order sidebands of a phase-modulated laser field, and which is locked using the H\"ansch--Couillaud method. In addition to the necessary attenuation, our interferometer introduces, via total internal reflection, a significant polarization-dependent phase delay. We employ a general treatment to describe an interferometer with an object which affects the field along one path, and we examine how this phase delay affects the error signal. We discuss the requirements necessary to ensure the lock point remains unchanged when phase modulation is introduced, and we demonstrate and characterize this locking experimentally. Finally, we suggest an extension to this locking strategy using heterodyne detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artifact removal from physiological signals is an essential component of the biosignal processing pipeline. The need for powerful and robust methods for this process has become particularly acute as healthcare technology deployment undergoes transition from the current hospital-centric setting toward a wearable and ubiquitous monitoring environment. Currently, determining the relative efficacy and performance of the multiple artifact removal techniques available on real world data can be problematic, due to incomplete information on the uncorrupted desired signal. The majority of techniques are presently evaluated using simulated data, and therefore, the quality of the conclusions is contingent on the fidelity of the model used. Consequently, in the biomedical signal processing community, there is considerable focus on the generation and validation of appropriate signal models for use in artifact suppression. Most approaches rely on mathematical models which capture suitable approximations to the signal dynamics or underlying physiology and, therefore, introduce some uncertainty to subsequent predictions of algorithm performance. This paper describes a more empirical approach to the modeling of the desired signal that we demonstrate for functional brain monitoring tasks which allows for the procurement of a ground truth signal which is highly correlated to a true desired signal that has been contaminated with artifacts. The availability of this ground truth, together with the corrupted signal, can then aid in determining the efficacy of selected artifact removal techniques. A number of commonly implemented artifact removal techniques were evaluated using the described methodology to validate the proposed novel test platform. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been suggested that there are significant overlaps between removals due to deregistration and removals arising because patients live outside the practice area. If this is true, it would mean that the current estimates of deregistration would need to be revised upwards. All outside-area removals for the calendar years 2001 and 2002 were reviewed and characterised by age, sex and Jarman score of the enumeration district of the patients' residence and distance from the practice. The average outside-area removal rate was just over one removal per practice per year. Removal rates were highest between the ages of 18 and 44 years; there were no significant differences between the sexes. Rates of removal increased exponentially with distance, although even at marked distances from the practice there were about 10 patients remaining on the list for each one removed. Residents in deprived areas were more likely to be removed, although because areas most distal to the practice tend to be affluent, overall there was a predominance of affluent patients among those who are removed. In Northern Ireland rates of outside-area removal are only slightly higher than those of deregistration. It is evident that GPs are exercising some discretion as to which of the outside-area patients they retain on their list. This has the potential to cause some misunderstanding and resentment among patients, as has been reported previously.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to describe the practice of central venous catheter (CVC) removal and outcomes of catheter-related bloodstream infection (CR-BSI) in adult haematology patients. Patients were identified retrospectively according to diagnosis coding of inpatient episodes and evaluated when, on examination of medical records, there had been evidence of sepsis with strong clinical suspicion that the source was the CVC. Demographic and bacteriological data, as well as therapeutic measures and clinical outcomes, were recorded. One hundred and three patient episodes were evaluated. The most frequent type of CVC was the Hickman catheter and the most frequently isolated pathogen was coagulase-negative staphylococci. Twenty-five percent of episodes were managed with catheter removal. Treatment failure, defined as recurrence of infection within 90 days or mortality attributed to sepsis within 30 days, occurred significantly more frequently in the group managed without catheter removal (52.5% versus 4%, P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel technique is described for the identification and quantification of environmental pollutants based on toxicity fingerprinting with a metabolic lux-marked bacterial biosensor. This method involved characterizing the toxicity-based responses of the biosensor to seven calibration pollutants as acute temporal-dose response fingerprints. An algorithm is described to allow comparisons of responses of an unknown pollutant to be made against the calibration data. This is based on predicting pollutant concentration at each of six different time points over the course of a 5-min assay. If the prediction is consistent between the unknown pollutant and a calibration pollutant at the 95% test level, this is considered to be a positive identification. All seven calibration pollutants could be successfully distinguished from each other with this technique. Environmental samples, individually spiked with single concentrations of pollutants, were compared in this way against the calibration pollutants. An 83% identification success was achieved, with no false positives at the 95% test level. This is a simple and rapid technique that potentially can be applied to monitoring of industrial wastewater or as a screening tool for regulators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flow of carbon from plant roots into soil supports a range of microbial processes and is therefore critical to ecosystem function and health. Pollution-induced stress, which influences rhizosphere C flow is of considerable potential importance, and therefore needs to be evaluated. This paper reports on a method, based on reporter gene technology, for quantifying pollutant effects on rhizosphere C flow. The method uses the lux-marked rhizobacterium Pseudomonas fluorescens, where bioluminescence output of this biosensor is directly correlated with the metabolic activity and reports on C flow in root exudate. Plantago lanceolata was treated with paraquat (representing a model pollutant stress) in a simple microcosm system. The lux-biosensor response correlated closely with C concentrations in the exudate and demonstrated that the pollutant stress increased the C flow from the plantago roots, 24 h after application of the herbicide. The lux-reporter system therefore potentially offers a technique for use in assessing the impact of pollutant stress on rhizosphere C flow through the soil microbial biomass.