68 resultados para pin-on-disc wear test


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Few studies have examined the impact that the adoption of the secret ballot had on party system fragmentation outside the United States. This article tests arguments maintaining that the adoption of the secret ballot had a negative, positive or nil effect on party system fragmentation. Using time-series cross-sectional data from
several countries adopting the secret ballot around the turn of the twentieth century, the results demonstrate that the adoption of the secret ballot did not hinder – though did not favour, either – the development of multiparty systems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The operational lifetime of hip replacement prostheses can be severely limited due to the occurrence of excessive wear at the load-bearing interfaces. The aim of this study was to investigate how the surface topography of articulating counterfaces evolves over the duration of a laboratory wear run. It was observed that modular stainless steel femoral heads wearing against ultrahigh molecular weight polyethylene (UHMWPE) can themselves be subject to wearing. A comparison with retrieved in vivo-aged femoral heads shows many topographical similarities: in a qualitative sense, scratching and pitting are evident on laboratory and in vivo-worn femoral heads; quantitatively, roughness comparisons between the new and worn devices are seen to increase typically by a factor of 4 after laboratory wearing. The observations suggest that a particular wear mode, namely third-body wear, is responsible for the increased roughness. It is conjectured that third bodies might arise through surface fatigue wear on the metal counterface, Wear debris is also observed to have been generated from the polymer surface, creating rounded debris with sizes predominantly in the range 0.4-0.8 microns: dimensions that are comparable to values previously reported for in vivo generated debris.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper reports an approach by which laboratory based testing and numerical modelling can be combined to predict the long term performance of a range of concretes exposed to marine environments. Firstly, a critical review of the test methods for assessing the chloride penetration resistance of concrete is given. The repeatability of the different test results is also included. In addition to the test methods, a numerical simulation model is used to explore the test data further to obtain long-term chloride ingress trends. The combined use of testing and modelling is validated with the help of long-term chloride ingress data from a North Sea exposure site. In summary, the paper outlines a methodology for determining the long term performance of concrete in marine environments.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

With a new test facility, we have investigated fretting fatigue properties of Ti-1023 titanium alloy at different contact pressure. Both fatigue fracture and fretting scar were analyzed by scanning electron microscopy (SEM). Moreover, the depth of crack initiation area in fatigue fracture has been analyzed quantitatively, to investigate the relationship between the depth of crack initiation area and the fretting fatigue strength. The changing trends of the depth of crack initiation area and fretting fatigue strength with the increase of contact pressure show obvious opposite correlations. The depth of crack initiation area increases rapidly with the increase of contact pressure at low contact pressure (smaller than 10 MPa), and the fretting fatigue strength drops rapidly. At the contact pressure of 10–45 MPa, both the depth of crack initiation area and the fretting fatigue strength do not vary significantly. Contact pressure influences fatigue strength through influencing the initiation of fatigue crack. The main damage patterns are fatigue flake and plow.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Electroless nickel (EN) and electroless nickel composite (ENC) coatings were deposited on aluminium alloy substrate, LM24. The micro abrasion test was conducted to study the wear behaviour of the coatings with the effect of SiC concentration. Microhardness of the coatings was tested also. The wear scars were analysed using optical microscope and scanning electron microscope (SEM). The wear resistance was found to be improved in composite coating that has higher microhardness as compared to particles free and the bare aluminium substrate. In as-deposited condition for the composite coating, the wear volume increases on increase in SiC percentage in the coating but is found to be minimum for lower SiC percentage. The increase in hardness on heat treatment at 400°C is due to the hardening or grain coarsening with the formation Ni3P.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Reasoning that is deliberative and reflective often requires the inhibition of intuitive responses. The Cognitive Reflection Test (CRT) is designed to assess people’s ability to suppress incorrect heuristic responses in favour of deliberation. Correct responding on the CRT predicts performance on a range of tasks in which intuitive processes lead to incorrect responses, suggesting indirectly that CRT performance is related to cognitive control. Yet little is known about the cognitive processes underlying performance on the CRT. In the current research, we employed a novel mouse tracking mjavascript:void(0);ethodology to capture the time-course of reasoning on the CRT. Analysis of mouse cursor trajectories revealed that participants were initially drawn towards the incorrect (i.e., intuitive) option even when the correct (deliberative) option was ultimately chosen. Conversely, participants were not attracted to the correct option when they ultimately chose the incorrect intuitive one. We conclude that intuitive processes are activated automatically on the CRT and must be inhibited in order to respond correctly. When participants responded intuitively, there was no evidence that deliberative reasoning had become engaged.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To assess the effect of provision of free glasses on academic performance in rural Chinese children with myopia. Design: Cluster randomized, investigator masked, controlled trial.Setting 252 primary schools in two prefectures in western China, 2012-13. Participants: 3177 of 19 934 children in fourth and fifth grades (mean age 10.5 years) with visual acuity <6/12 in either eye without glasses correctable to >6/12 with glasses. 3052 (96.0%) completed the study.Interventions Children were randomized by school (84 schools per arm) to one of three interventions at the beginning of the school year: prescription for glasses only (control group), vouchers for free glasses at a local facility, or free glasses provided in class. Main outcome measures: Spectacle wear at endline examination and end of year score on a specially designed mathematics test, adjusted for baseline score and expressed in standard deviations. Results: Among 3177 eligible children, 1036 (32.6%) were randomized to control, 988 (31.1%) to vouchers, and 1153 (36.3%) to free glasses in class. All eligible children would benefit from glasses, but only 15% wore them at baseline. At closeout glasses wear was 41% (observed) and 68% (self reported) in the free glasses group, and 26% (observed) and 37% (self reported) in the controls. Effect on test score was 0.11 SD (95% confidence interval 0.01 to 0.21) when the free glasses group was compared with the control group. The adjusted effect of providing free glasses (0.10, 0.002 to 0.19) was greater than parental education (0.03, −0.04 to 0.09) or family wealth (0.01, −0.06 to 0.08). This difference between groups was significant, but was smaller than the prespecified 0.20 SD difference that the study was powered to detect. Conclusions: The provision of free glasses to Chinese children with myopia improves children’s performance on mathematics testing to a statistically significant degree, despite imperfect compliance, although the observed difference between groups was smaller than the study was originally designed to detect. Myopia is common and rarely corrected in this setting. Trial Registration: Current Controlled Trials ISRCTN03252665.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE:

To determine the test-retest variability in perimetric, optic disc, and macular thickness parameters in a cohort of treated patients with established glaucoma.

PATIENTS AND METHODS:

In this cohort study, the authors analyzed the imaging studies and visual field tests at the baseline and 6-month visits of 162 eyes of 162 participant in the Glaucoma Imaging Longitudinal Study (GILS). They assessed the difference, expressed as the standard error of measurement, of Humphrey field analyzer II (HFA) Swedish Interactive Threshold Algorithm fast, Heidelberg retinal tomograph (HRT) II, and retinal thickness analyzer (RTA) parameters between the two visits and assumed that this difference was due to measurement variability, not pathologic change. A statistically significant change was defined as twice the standard error of measurement.

RESULTS:

In this cohort of treated glaucoma patients, it was found that statistically significant changes were 3.2 dB for mean deviation (MD), 2.2 for pattern standard deviation (PSD), 0.12 for cup shape measure, 0.26 mm for rim area, and 32.8 microm and 31.8 microm for superior and inferior macular thickness, respectively. On the basis of these values, it was estimated that the number of potential progression events detectable in this cohort by the parameters of MD, PSD, cup shape measure, rim area, superior macular thickness, and inferior macular thickness was 7.5, 6.0, 2.3, 5.7, 3.1, and 3.4, respectively.

CONCLUSIONS:

The variability of the measurements of MD, PSD, and rim area, relative to the range of possible values, is less than the variability of cup shape measure or macular thickness measurements. Therefore, the former measurements may be more useful global measurements for assessing progressive glaucoma damage.