145 resultados para microbial conversion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ubiquitous noxious hydrophobic substances, such as hydrocarbons, pesticides and diverse industrial chemicals, stress biological systems and thereby affect their ability to mediate biosphere functions like element and energy cycling vital to biosphere health. Such chemically diverse compounds may have distinct toxic activities for cellular systems; they may also share a common mechanism of stress induction mediated by their hydrophobicity. We hypothesized that the stressful effects of, and cellular adaptations to, hydrophobic stressors operate at the level of water : macromolecule interactions. Here, we present evidence that: (i) hydrocarbons reduce structural interactions within and between cellular macromolecules, (ii) organic compatible solutes-metabolites that protect against osmotic and chaotrope-induced stresses-ameliorate this effect, (iii) toxic hydrophobic substances induce a potent form of water stress in macromolecular and cellular systems, and (iv) the stress mechanism of, and cellular responses to, hydrophobic substances are remarkably similar to those associated with chaotrope-induced water stress. These findings suggest that it may be possible to devise new interventions for microbial processes in both natural environments and industrial reactors to expand microbial tolerance of hydrophobic substances, and hence the biotic windows for such processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anisotropic impedance surfaces are employed as low-profile and broadband reflectors that convert orthogonal linear to right- and left-handed circular polarization respectively. By virtue of anisotropy, it is possible to independently control the reflection characteristics of two orthogonal linearly polarized incident plane waves and therefore achieve linear to circular polarization conversion. Equivalent circuits for anisotropic impedance surfaces with arbitrarily shaped elements are employed to demonstrate the operating principle and a design procedure is proposed. The proposed design procedure is demonstrated by means of an example involving a dipole array. A prototype is designed and its performance characteristics are evaluated. The 3-dB relative axial ratio bandwidth exceeds 60%, while low loss and angular stability are also reported. Numerical and experimental results on a fabricated prototype are presented to validate the synthesis and the performance. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organometallic hydrogen transfer and dehydrogenation provide straightforward atom efficient routes from alcohols to a variety of chemical products. The potential of these reactions to enable the conversion of biomass to value added chemicals is discussed, with reference to the products that can be prepared from aliphatic alcohols in good isolated yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whilst there are a number of methods available to characterise the cell surface hydrophobicity (CSH) and cell surface charge (CSC) of microorganisms, there is still debate concerning the correlation of results between individual methods. In this study, the techniques of bacterial adherence to hydrocarbons (BATH) and hydrophobic interaction chromatography (HTC) were used to measure CSH. Electrostatic interaction chromatography (ESIC) and zeta potential (ZP) measurements were used to determine CSC. To allow meaningful comparisons between the BATH and HIC tests, between ESIC and ZP and also between CSH and CSC, the buffer systems employed in each test were standardised (phosphate buffered saline, pH 7.3, 0.01 mM). Isolates of Staphylococcus epidermidis derived from microbial biofilm were used as the test organism in this study. The isolates examined exhibited primarily medium to high CSH and a highly negative CSC. Good correlation of CSH measurement was observed between the BATH and HIC tests (r = 0.89). Good correlation was observed between ESIC (anionic exchange column) and ZP measurements. No correlations were observed between isolate CSC and either increased or decreased CSH. It is recommended that whenever comparisons of various methods to determine either CSC or CSH (by partitioning methods), the buffer systems should remain constant throughout to achieve consistency of results.

Relevância:

20.00% 20.00%

Publicador: