83 resultados para incompleteness and inconsistency detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study conducted to evaluate the effectiveness of four assistive technology (AT) tools on literacy: (1) speech synthesis, (2) spellchecker, (3) homophone tool, and (4) dictionary. All four of these programs are featured in TextHelp’s Read&Write Gold software package. A total of 93 secondary-level students with reading disabilities participated in the study. The participants completed a number of computer-based literacy tests after being assigned to a Read&Write group or a control group that utilized Microsoft Word. The results indicated that improvements in the following areas for the Read&Write group: (1) reading comprehension, (2) homophone error detection, (3) spelling error detection, and (4) word meanings. The Microsoft Word group also improved in the areas of word meanings and error detection, though performed worse on homophone error detection. The authors contend that these results indicate that speech synthesis, spell checkers, homophone tools, and dictionary programs have a positive effect on literacy among students with reading disabilities. This study was conducted by researchers at the Queen’s University in Belfast, Ireland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-performance liquid chromatography (HPLC) methodologies were evaluated for the detection and quantification of thyreostatic drug residues in cattle serum and thyroid tissue. The paper details a protocol, using a simple ethyl acetate extraction for the determination of thiouracil, tapazole, methyl thiouracil, propyl thiouracil and phenyl thiouracil in thyroid tissue. Using two sequential HPLC injections, and quantitative analysis, in two steps, all five thyreostats were detectable at concentrations greater than 2.45-4.52 ng/g. Modifications to a published method for detection of thyreostatic residues in serum involving the addition of mercaptoethanol and a freezing step are described. The modifications improved sensitivity and allowed detection of the five thyreostats at levels greater than 16.98-35.25 ng/ml. Young bulls were treated with thyreostats to demonstrate the validity of the methodologies described. Administered thyreostats were not absorbed equally by the test animals and the compounds were not all detected in the serum samples removed at 7 days following drug withdrawal. These experiments indicate the necessity to be able to detect thyreostat residues in a variety of matrices. (C) 1998 Elsevier Science B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel stir bar sorptive extraction (SBSE) method coupled with high performance liquid chromatography (HPLC) and UV detection for the extraction of diclofenac (DIC) from paediatric urine samples has been developed and validated. Selectivity and sensitivity being the prime objectives of the bioanalytical method for clinical samples, an optimised SBSE protocol was developed that selectively extracted DIC from various concurrently administered drugs. The validated assay was found to be linear (r=0.9999) over a concentration range of 100-2000 ng mL(-1). SBSE showed consistent recoveries (similar to 70%) of DIC across the validated linearity range. Overall, the method exhibited excellent accuracy and precision across all QC concentrations, tested over three days. Calculated LOD and LOQ were found to be 12.03 ng mL(-1) and 36.37 ng mL(-1), respectively, however, for the experimental purposes, 100 ngmL(-1) was considered as the validated LOQ(accuracy and precision at this LQC was

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bystander responses underlie some of the current efforts to develop gene therapy approaches for cancer treatment. Similarly, they may have a role in strategies to treat tumours with targeted radioisotopes. In this study we show direct evidence for the production of a radiation-induced bystander response in primary human fibroblasts, We utilize a novel approach of using a charged-particle microbeam, which allows individual cells within a population to be selected and targeted with counted charged particles. Individual primary human fibroblasts within a population of 600-800 cells were targeted with between 1 and 15 helium ions (effectively, alpha -particles). The charged particles were delivered through the centre of the nucleus with an accuracy of +/- 2 mum and a detection and counting efficiency of greater than 99%. When scored 3 days later, even though only a single cell had been targeted, typically an additional 80-100 damaged cells were observed in the surviving population of about 5000 cells. The yield of damaged cells was independent of the number of charged particles delivered to the targeted cell, Similar results of a 2-3-fold increase in the background level of damage present in the population were observed whether 1 or 4 cells were targeted within the dish. Also, when 200 cells within one quadrant of the dish were exposed to radiation, there was a 2-3-fold increase in the damage level in an unexposed quadrant of the dish, This effect was independent of the presence of serum in the culture medium and was only observed when a cell was targeted, but not when only the medium was exposed, confirming that a cell-mediated response is involved. (C) 2001 Cancer Research Campaign.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Geoscience methods are increasingly being utilised in criminal, environmental and humanitarian forensic investigations, and the use of such methods is supported by a growing body of experimental and theoretical research. Geoscience search techniques can complement traditional methodologies in the search for buried objects, including clandestine graves, weapons, explosives, drugs, illegal weapons, hazardous waste and vehicles. This paper details recent advances in search and detection methods, with case studies and reviews. Relevant examples are given, together with a generalised workflow for search and suggested detection technique(s) table. Forensic geoscience techniques are continuing to rapidly evolve to assist search investigators to detect hitherto difficult to locate forensic targets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A scanning probe microscopy approach for mapping local irreversible electrochemical processes based on detection of bias-induced frequency shifts of cantilevers in contact with the electrochemically active surface is demonstrated. Using Li ion conductive glass ceramic as a model, we demonstrate near unity transference numbers for ionic transport and establish detection limits for current-based and strain-based detection. The tip-induced electrochemical process is shown to be a first-order transformation and nucleation potential is close to the Li metal reduction potential. Spatial variability of the nucleation bias is explored and linked to the local phase composition. These studies both provide insight into nanoscale ionic phenomena in practical Li-ion electrolyte and also open pathways for probing irreversible electrochemical, bias-induced, and thermal transformations in nanoscale systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A proof-of-concept study was reported on analysis of antigen–antibody recognition based on resonant Rayleigh scattering response of single Au nanoparticles in an imaging chamber. As benefited by a traditional dark-field microscope and a spectrograph, individual Au nanoparticles (30 nm) were observed with high signal-to-noise ratio and they were effectively utilized to monitor changes in refractive index induced by specific binding of the adsorbates. Using PSA antigen as a model, a LSPR ?max shift of about 2.85 nm was recorded for a molecular binding corresponding to 0.1 pg ml-1 of the protein biomarker. This result successfully demonstrates a non-labeling detection system for proteins as well as thousands of different chemical or biological species, and it possesses a great potential as a sensitive, on-chip and multiplexing detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiplexed immunochemical detection platforms offer the potential to decrease labour demands, increase sample throughput and decrease overall time to result. A prototype four channel multiplexed high throughput surface plasmon resonance biosensor was previously developed, for the detection of food related contaminants. A study focused on determining the instruments performance characteristics was undertaken. This was followed by the development of a multiplexed assay for four high molecular weight proteins. The protein levels were simultaneously evaluated in serum samples of 10-week-old veal calves (n = 24) using multiple sample preparation methods. Each of the biosensor's four channels were shown to be independent of one another and produced multiplexed within run repeatability (n = 6) ranging from 2.0 to 6.7%CV, for the four tested proteins, whilst between run reproducibility (n = 4) ranged from 1.5 to 8.9%CV. Four calibration curves were successfully constructed before serum sample preparation was optimised for each protein. Multiplexed concentration analysis was successfully performed on four channels revealing that each proteins concentration was consistent across the twenty-four tested animals. Signal reproducibility (n > 19) on a further long term study revealed coefficient of variation ranging from 1.1% to 7.3% and showed that the multiplexed assay was stable for at least 480 cycles. These findings indicate that the performance characteristics fall within the range of previously published data for singleplex optical biosensors and that the multiplexing biosensor is fit-for-purpose for simultaneous concentration analysis in many different types of applications such as the multiplexed detection of markers of growth-promoter abuse and multiplexed detection of residues of concern in food safety. © 2013 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Stellar activity, such as starspots, can induce radial velocity (RV) variations that can mask or even mimic the RV signature of orbiting exoplanets. For this reason RV exoplanet surveys have been unsuccessful when searching for planets around young, active stars and are therefore failing to explore an important regime which can help to reveal how planets form and migrate. This paper describes a new technique to remove spot signatures from the stellar line-profiles of moderately rotating, active stars (v sin i ranging from 10 to 50 km s(-1)). By doing so it allows planetary RV signals to be uncovered. We used simulated models of a G5V type star with differing dark spots on its surface along with archive data of the known active star HD 49933 to validate our method. The results showed that starspots could be effectively cleaned from the line-profiles so that the stellar RV jitter was reduced by more than 80 per cent. Applying this procedure to the same models and HD 49933 data, but with fake planets injected, enabled the effective removal of starspots so that Jupiter mass planets on short orbital periods were successfully recovered. These results show that this approach can be useful in the search for hot-Jupiter planets that orbit around young, active stars with a v sin i of similar to 10-50 km/s.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a preliminary study of developing a novel distributed adaptive real-time learning framework for wide area monitoring of power systems integrated with distributed generations using synchrophasor technology. The framework comprises distributed agents (synchrophasors) for autonomous local condition monitoring and fault detection, and a central unit for generating global view for situation awareness and decision making. Key technologies that can be integrated into this hierarchical distributed learning scheme are discussed to enable real-time information extraction and knowledge discovery for decision making, without explicitly accumulating and storing all raw data by the central unit. Based on this, the configuration of a wide area monitoring system of power systems using synchrophasor technology, and the functionalities for locally installed open-phasor-measurement-units (OpenPMUs) and a central unit are presented. Initial results on anti-islanding protection using the proposed approach are given to illustrate the effectiveness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite ethical and technical concerns, the in vivo method, or more commonly referred to mouse bioassay (MBA), is employed globally as a reference method for phycotoxin analysis in shellfish. This is particularly the case for paralytic shellfish poisoning (PSP) and emerging toxin monitoring. A high-performance liquid chromatography method (HPLC-FLD) has been developed for PSP toxin analysis, but due to difficulties and limitations in the method, this procedure has not been fully implemented as a replacement. Detection of the diarrhetic shellfish poisoning (DSP) toxins has moved towards LC-mass spectrometry (MS) analysis, whereas the analysis of the amnesic shellfish poisoning (ASP) toxin domoic acid is performed by HPLC. Although alternative methods of detection to the MBA have been described, each procedure is specific for a particular toxin and its analogues, with each group of toxins requiring separate analysis utilising different extraction procedures and analytical equipment. In addition, consideration towards the detection of unregulated and emerging toxins on the replacement of the MBA must be given. The ideal scenario for the monitoring of phycotoxins in shellfish and seafood would be to evolve to multiple toxin detection on a single bioanalytical sensing platform, i.e. 'an artificial mouse'. Immunologically based techniques and in particular surface plasmon resonance technology have been shown as a highly promising bioanalytical tool offering rapid, real-time detection requiring minimal quantities of toxin standards. A Biacore Q and a prototype multiplex SPR biosensor have been evaluated for their ability to be fit for purpose for the simultaneous detection of key regulated phycotoxin groups and the emerging toxin palytoxin. Deemed more applicable due to the separate flow channels, the prototype performance for domoic acid, okadaic acid, saxitoxin, and palytoxin calibration curves in shellfish achieved detection limits (IC20) of 4,000, 36, 144 and 46 μg/kg of mussel, respectively. A one-step extraction procedure demonstrated recoveries greater than 80 % for all toxins. For validation of the method at the 95 % confidence limit, the decision limits (CCα) determined from an extracted matrix curve were calculated to be 450, 36 and 24 μg/kg, and the detection capability (CCβ) as a screening method is ≤10 mg/kg, ≤160 μg/kg and ≤400 μg/kg for domoic acid, okadaic acid and saxitoxin, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When implementing autonomic management of multiple non-functional concerns a trade-off must be found between the ability to develop independently management of the individual concerns (following the separation of concerns principle) and the detection and resolution of conflicts that may arise when combining the independently developed management code. Here we discuss strategies to establish this trade-off and introduce a model checking based methodology aimed at simplifying the discovery and handling of conflicts arising from deployment-within the same parallel application-of independently developed management policies. Preliminary results are shown demonstrating the feasibility of the approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rapid immunoanalytical screening of food and environmental samples for small molecular weight (hapten) biotoxin contaminations requires the production of antibody reagents that possess the requisite sensitivity and specificity. To date animal-derived polyclonal (pAb) and monoclonal (mAb) antibodies have provided the binding element of the majority of these assays but recombinant antibodies (rAb) isolated from in vitro combinatorial phage display libraries are an exciting alternative due to (1) circumventing the need for experimental animals, (2) speed of production in commonly used in vitro expression systems and (3) subsequent molecular enhancement of binder performance. Short chain variable fragments (scFv) have been the most commonly employed rAb reagents for hapten biotoxin detection over the last two decades but antibody binding fragments (Fab) and single domain antibodies (sdAb) are increasing in popularity due to increased expression efficiency of functional binders and superior resistance to solvents. rAb-based immunochromatographic assays and surface plasmon resonance (SPR) biosensors have been reported to detect sub-regulatory levels of fungal (mycotoxins), marine (phycotoxins) and aquatic biotoxins in a wide range of food and environmental matrices, however this technology has yet to surpass the performances of the equivalent mAb- and pAb-based formats. As such the full potential of rAb technology in hapten biotoxin detection has yet to be achieved, but in time the inherent advantages of engineered rAb are set to provide the next generation of ultra-high performing binder reagents for the rapid and specific detection of hapten biotoxins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the first planet discovery from the two-wheeled Kepler (K2) mission: HIP 116454 b. The host star HIP 116454 is a bright (V = 10.1, K = 8.0) K1 dwarf with high proper motion and a parallax-based distance of 55.2 +/- 5.4 pc. Based on high-resolution optical spectroscopy, we find that the host star is metal-poor with [Fe/H]= -0.16 +/- 0.08 and has a radius R-star = 0.716 +/- 0.024 R-circle dot and mass M-star = 0.775 +/- 0.027M(circle dot). The star was observed by the Kepler spacecraft during its Two-Wheeled Concept Engineering Test in 2014 February. During the 9 days of observations, K2 observed a single transit event. Using a new K2 photometric analysis technique, we are able to correct small telescope drifts and recover the observed transit at high confidence, corresponding to a planetary radius of R-p = 2.53 +/- 0.18 R-circle plus. Radial velocity observations with the HARPS-N spectrograph reveal a 11.82 +/- 1.33 M-circle plus planet in a 9.1 day orbit, consistent with the transit depth, duration, and ephemeris. Follow-up photometric measurements from the MOST satellite confirm the transit observed in the K2 photometry and provide a refined ephemeris, making HIP 116454 b amenable for future follow-up observations of this latest addition to the growing population of transiting super-Earths around nearby, bright stars.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rapid and sensitive detection of viral infections associated with Bovine Respiratory Disease (BRD) in live animals is recognized as key to minimizing the impact of this disease. ELISA-based testing is limited as it typically relies on the detection of a single viral antibody subtype within an individual test sample and testing is relatively slow and expensive. We have recently initiated a new project entitled AgriSense to develop a novel low-cost and label-free, integrated bimodal electronic biosensor system for BRD. The biosensor system will consist of an integrated multichannel thin-film-transistor biosensor and an electrochemical impedance spectroscopy biosensor, interfaced with PDMS-based microfluidic sample delivery channels. By using both sensors in tandem, nonspecific binding biomolecules must have the same mass to charge ratio as the target analyte to elicit equivalent responses from both sensors. The system will target simultaneous multiplexed sensing of the four primary viral agents involved in the development of BRD: bovine herpesvirus-1 (BHV-1), bovine parainfluenza virus-3 (BPIV-3), bovine respiratory syncytial virus (BRSV), and bovine viral diarrhea (BVD). Optimized experimental conditions derived through model antigen-antibody studies will be applied to the detection of serological markers of BRD-related infections based on IgG interaction with a panel of sensor-immobilized viral proteins. This rapid, “cowside” multiplex sensor capability presents a major step forward in disease diagnosis, helping to ensure the integrity of the agri-food supply chain by reducing the risk of disease spread during animal movement and transport.