94 resultados para implant impression accuracy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: PET/CT scanning can determine suitability for curative therapy and inform decision making when considering radical therapy in patients with non-small cell lung cancer (NSCLC). Metastases to central mediastinal lymph nodes (N2) may alter such management decisions. We report a 2 year retrospective series assessing N2 lymph node staging accuracy with PET/CT compared to pathological analysis at surgery.

METHODS: Patients with NSCLC attending our centre (excluding those who had induction chemotherapy) who had staging PET/CT scans and pathological nodal sampling between June 2006 and June 2008 were analysed. For each lymph node assessed pathologically, the corresponding PET/CT status was determined. 64 patients with 200 N2 lymph nodes were analysed.

RESULTS: Sensitivity of PET/CT scans for indentifying involved N2 lymph nodes was
39%, specificity 96% and overall accuracy 90%. For individual lymph node analysis, logistic regression demonstrated a significant linear association between PET/CT sensitivity and time from scanning to surgery (p=0.031) but not for specificity and accuracy. Those scanned <9 weeks before pathological sampling were significantly more sensitive (64% >9 weeks, 0% ≥ 9 weeks, p=0.013) and more accurate (94% <9 weeks, 81% ≥ 9 weeks, p=0.007). Differences in specificity were not seen (97% <9 weeks, 91% ≥ 9 weeks, p=0.228). No significant difference in specificity was found at any time point.

CONCLUSIONS: We recommend that if a PET/CT scan is older than 9 weeks, and management would be altered by the presence of N2 nodes, re-staging of the
mediastinum should be undertaken.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Immediate reconstruction following mastectomy for breast cancer has been shown to be oncologically safe and associated with improved psychosocial outcomes for patients. Bostwick described a technique for one-stage implant based reconstruction, combining skin-sparing mastectomy with concurrent reduction of the skin envelope. This report reviews the experience of a single centre using skin-reducing mastectomy and one-stage implant reconstruction in both early stage breast cancer and risk-reducing mastectomy, with specific reference to frequency of complications, implant loss and oncological outcomes.

Methods and results: A retrospective review was undertaken to identify women who had undergone skin-reducing mastectomy and one-stage implant reconstruction using a de-epithelialised dermal flap, between October 2008 and October 2012. One hundred and four consecutive mastectomies, with reconstruction, were performed by two surgeons on 64 patients. No complications were seen in 43.8% of patients. At three months, four implants were lost (3.8% of breast reconstructions, 6.3% of patients), due to either peri-implant infection or mastectomy skin flap necrosis. One patient required unplanned return to theatre for evacuation of a haematoma. Minor mastectomy skin flap necrosis was seen in 10 breasts (9.6% of reconstructed breasts) and superficial wound infection in 8 breasts (7.7% of reconstructed breasts). All of these complications were managed conservatively and none required operative intervention. At a median follow up of 35 months (4-53 months) there had been one episode of ipsilateral axillary nodal recurrence.

Conclusion: One-stage implant reconstruction using a myo-dermal flap technique following skin-reducing mastectomy is safe and should be considered in selected patients. Most complications are minor and will resolve with conservative management. Major complications such as implant failure or immediate reoperation, were relatively uncommon (6.3% patients, 3.8% of reconstructed breasts). Early follow-up suggests that oncological outcomes are satisfactory, but longer follow-up is required to substantiate this. (C) 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Breast augmentation for cosmetic purposes is an increasingly common procedure in the USA and UK. In the USA in 2003, a total of 254 140 breast augmentation procedures were carried out [American Society of Plastic Surgeons, http://www.plasticsurgery.org/newsroom/ Procedural-Statistics-Press-Kit-Index.cfm9-1-2005; 2006.(1)]. It has been previously estimated that between 1 and 1.5 million women in the USA have prosthetic breast implants [Cook RR, Delongchamp RR, Woodbury M, et at. The prevalence of women with breast implants in the United States, 1989. J Clin Epidemiol 1995;48:519-25.(2)]. The UK National Breast Implant Registry has recorded a rise in the numbers of women receiving breast implants, with over 13 000 procedures registered in 2001; an estimated 77% of these were for cosmetic purposes. No association has been found between the presence of breast implants in a breast and an increased risk of breast cancer, and this subject has been comprehensively reviewed elsewhere [Hoshaw SJ, Klein PJ, Clark BD, et al. Breast implants and cancer: causation, delayed detection, and survival. Plast Reconstr Surg 2001; 107:1393-407.(3)]. However, as the population of women with breast implants ages, an increasing number of them will develop breast cancer; a reflection of the fact that the incidence of the disease increases with increasing age. Debate continues on the effect of breast implants on the efficacy of mammography in diagnosing breast cancer, and the role of other imaging techniques for this purpose, as well as the limitations that the presence of implants place on percutaneous biopsy techniques. We review the Literature on the radiological and tissue diagnosis of breast cancer in women with a history of previous augmentation mammaplasty. (c) 2007 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Excessive use of empirical antibiotics is common in critically ill patients. Rapid biomarker-based exclusion of infection may improve antibiotic stewardship in ventilator-acquired pneumonia (VAP). However, successful validation of the usefulness of potential markers in this setting is exceptionally rare.

Objectives: We sought to validate the capacity for specific host inflammatory mediators to exclude pneumonia in patients with suspected VAP. 

Methods: A prospective, multicentre, validation study of patients with suspected VAP was conducted in 12 intensive care units. VAP was confirmed following bronchoscopy by culture of a potential pathogen in bronchoalveolar lavage fluid (BALF) at >104 colony forming units per millilitre (cfu/mL). Interleukin-1 beta (IL-1β), IL-8, matrix metalloproteinase-8 (MMP-8), MMP-9 and human neutrophil elastase (HNE) were quantified in BALF. Diagnostic utility was determined for biomarkers individually and in combination. 

Results: Paired BALF culture and biomarker results were available for 150 patients. 53 patients (35%) had VAP and 97 (65%) patients formed the non-VAP group. All biomarkers were significantly higher in the VAP group (p<0.001). The area under the receiver operator characteristic curve for IL-1β was 0.81; IL-8, 0.74; MMP-8, 0.76; MMP-9, 0.79 and HNE, 0.78. A combination of IL-1β and IL-8, at the optimal cut-point, excluded VAP with a sensitivity of 100%, a specificity of 44.3% and a post-test probability of 0% (95% CI 0% to 9.2%). 

Conclusions: Low BALF IL-1β in combination with IL-8 confidently excludes VAP and could form a rapid biomarker-based rule-out test, with the potential to improve antibiotic stewardship.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: There is an urgent need to develop diagnostic tests to improve the detection of pathogens causing life-threatening infection (sepsis). SeptiFast is a CE-marked multi-pathogen real-time PCR system capable of detecting DNA sequences of bacteria and fungi present in blood samples within a few hours. We report here a systematic review and meta-analysis of diagnostic accuracy studies of SeptiFast in the setting of suspected sepsis.

Methods: A comprehensive search strategy was developed to identify studies that compared SeptiFast with blood culture in suspected sepsis. Methodological quality was assessed using QUADAS. Heterogeneity of studies was investigated using a coupled forest plot of sensitivity and specificity and a scatter plot in receiver operator characteristic space. Bivariate model method was used to estimate summary sensitivity and specificity.

Results: From 41 phase III diagnostic accuracy studies, summary sensitivity and specificity for SeptiFast compared with blood culture were 0.68 (95 % CI 0.63–0.73) and 0.86 (95 % CI 0.84–0.89) respectively. Study quality was judged to be variable with important deficiencies overall in design and reporting that could impact on derived diagnostic accuracy metrics.

Conclusions: SeptiFast appears to have higher specificity than sensitivity, but deficiencies in study quality are likely to render this body of work unreliable. Based on the evidence presented here, it remains difficult to make firm recommendations about the likely clinical utility of SeptiFast in the setting of suspected sepsis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Titanium has good biocompatibility and so its alloys are used as implant materials, but they suffer from having poor wear resistance. This research aims to improve the wear resistance and the tensile strength of titanium alloys potentially for implant applications. Titanium alloys Ti–6Al–4V and Ti–6Al–7Nb were subjected to shotpeening process to study the wear and tensile behavior. An improvement in the wear resistance has been achieved due to surface hardening of these alloys by the process of shotpeening. Surface microhardness of shotpeened Ti–6Al–4V and Ti–6Al–7Nb alloys has increased by 113 and 58 HV(0.5), respectively. After shotpeening, ultimate tensile strength of Ti–6Al–4V increased from 1000 MPa to 1150 MPa, higher than improvement obtained for heat treated titanium specimens. The results confirm that shotpeening pre-treatment improved tensile and sliding wear behavior of Ti–6Al–4V and Ti–6Al–7Nb alloys. In addition, shotpeening increased surface roughness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background

]In modern radiotherapy, it is crucial to monitor the performance of all linac components including gantry, collimation system and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method has been introduced in conjunction with an algorithm to investigate the stability of these systems during arc treatments with the aim of ensuring the accuracy of linac mechanical performance.


Methods

The Varian EPID sag, gantry sag, changes in source-to-detector distance (SDD), EPID and collimator skewness, EPID tilt, and the sag in MLC carriages as a result of linac rotation were separately investigated by acquisition of EPID images of a simple phantom comprised of 5 ball-bearings during arc delivery. A fast and robust software package was developed for automated analysis of image data. Twelve Varian linacs of different models were investigated.


Results

The average EPID sag was within 1 mm for all tested linacs. All machines showed less than 1 mm gantry sag. Changes in SDD values were within 1.7 mm except for three linacs of one centre which were within 9 mm. Values of EPID skewness and tilt were negligible in all tested linacs. The maximum sag in MLC leaf bank assemblies was around 1 mm. The EPID sag showed a considerable improvement in TrueBeam linacs.


Conclusion

The methodology and software developed in this study provide a simple tool for effective investigation of the behaviour of linac components with gantry rotation. It is reproducible and accurate and can be easily performed as a routine test in clinics.




Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective:

The aim of this study was to identify sources of anatomical misrepresentation due to the location of camera mounting, tumour motion velocity and image processing artefacts in order to optimise the 4DCT scan protocol and improve geometrical-temporal accuracy.

Methods:

A phantom with an imaging insert was driven with a sinusoidal superior-inferior motion of varying amplitude and period for 4DCT scanning. The length of a high density cube within the insert was measured using treatment planning software to determine the accuracy of its spatial representation. Scan parameters were varied including the tube rotation period and the cine time between reconstructed images. A CT image quality phantom was used to measure various image quality signatures under the scan parameters tested.

Results:

No significant difference in spatial accuracy was found for 4DCT scans carried out using the wall mounted or couch mounted camera for sinusoidal target motion. Greater spatial accuracy was found for 4DCT scans carried out using a tube rotation speed of 0.5s rather than 1.0s. The reduction in image quality when using a faster rotation speed was not enough to require an increase in patient dose.

Conclusions:

4DCT accuracy may be increased by optimising scan parameters, including choosing faster tube rotation speeds. Peak misidentification in the recorded breathing trace leads to spatial artefacts and this risk can be reduced by using a couch mounted infrared camera.

Advances in knowledge:

This study explicitly shows that 4DCT scan accuracy is improved by scanning with a faster CT tube rotation speed.