99 resultados para dentin sensitivity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: Myocardial ischemia/reperfusion (I/R) is associated with mitochondrial dysfunction and subsequent cardiomyocyte death. The generation of excessive quantities of reactive oxygen species (ROS) and resultant damage to mitochondrial enzymes is considered an important mechanism underlying reperfusion injury. Mitochondrial complex I can exist in two interconvertible states: active (A) and deactive or dormant (D). We have studied the active/deactive (A/D) equilibrium in several tissues under ischemic conditions in vivo and investigated the sensitivity of both forms of the heart enzyme to ROS.

Results: We found that in the heart, t½ of complex I deactivation during ischemia was 10?min, and that reperfusion resulted in the return of A/D equilibrium to its initial level. The rate of superoxide generation by complex I was higher in ischemic samples where content of the D-form was higher. Only the D-form was susceptible to inhibition by H2O2 or superoxide, whereas turnover-dependent activation of the enzyme resulted in formation of the A-form, which was much less sensitive to ROS. The mitochondrial-encoded subunit ND3, most likely responsible for the sensitivity of the D-form to ROS, was identified by redox difference gel electrophoresis.

Innovation: A combined in vivo and biochemical approach suggests that sensitivity of the mitochondrial system to ROS during myocardial I/R can be significantly affected by the conformational state of complex I, which may therefore represent a new therapeutic target in this setting.

Conclusion: The presented data suggest that transition of complex I into the D-form in the absence of oxygen may represent a key event in promoting cardiac injury during I/R.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Predictive validity of the Stanford-Binet Intelligence Scale Fourth Edition (S-B IV) from age 3 years to ages 4-5 years was evaluated with biologically "at risk" children without major sensory or motor impairments (n = 236). Using the standard scoring, children with full scale IQ <or = 84 on the Wechsler Preschool and Primary Scale of Intelligence at age 4-5 years were poorly identified (sensitivity 54%) from the composite S-B IV score at age 3. However, sensitivity improved greatly to 78% by including as a predictor the number of subtests the child was actually able to perform at age 3 years. Measures from the Home Screening Questionnaire and ratings of mother-child interaction further improved sensitivity to 83%. The standard method for calculating the composite score on the S-B IV excludes subtests with a raw score of 0, which overestimates cognitive functioning in young biologically high risk children. Accuracy of early identification was improved significantly by considering the number of subtests the child did not perform at age 3 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-technology medical care of extremely low-birth-weight (ELBW) infants (<1001 g) involves repeated medical interventions which are potentially painful and may later affect reaction to pain. At 18 months corrected age (CCA), we examined parent ratings of pain sensitivity and how pain sensitivity ratings related to child temperament and parenting style in 2 groups of ELBW children (49 with a birth weight of 480-800 g and 75 with a birth weight of 801-1000 g) and 2 control groups (42 heavier preterm (1500-2499 g) and 29 full-birth-weight (FBW) children (> 2500 g). Both groups of ELBW toddlers were rated by parents as significantly lower in pain sensitivity compared with both control groups. The relationships between child temperament and pain sensitivity rating varied systematically across the groups. Temperament was strongly related to rated pain sensitivity in the FBW group, moderately related in the heavier preterm and ELBW 801-1000 g groups, and not related in the lowest birth-weight group (<801 g). Parental style did not mediate ratings of pain sensitivity. The results suggest that parents perceive differences in pain behavior of ELBW toddlers compared with heavier preterm and FBW toddlers, especially for those less than 801 g. Longitudinal research into the development of pain behavior for infants who experience lengthy hospitalization is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydrogen is detected using a Pd/n-InP Schottky diode in which the elongated, very thin Pd electrode is of greater resistance than the underlying semiconductor substrate. Four-probe measurements of the device resistance, as a function of hydrogen concentration, are made by contacting only the Pd electrode, with a sensitivity of 1 ppm being achieved. On hydrogen exposure the device resistance drops from an initial high value, characteristic of the Pd electrode alone, to a lower value due to a hydrogen-induced lowering of the Schottky barrier that opens up the InP substrate as a parallel current carrying channel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the temporal course of corneal sensitivity loss & the role of aldose reductase inhibitors (ARI) in an animal model of diabetic ocular complications. Methods: Weanling male S-D rats were randomly grouped to received ad libitum water & diet consisting of Purina (#5001) w/ either: 50% starch (CON,n=15) or 50% D-galactose (GAL,n=30). Half the galactosemic rats (ARI,n=15) received topical 0.25% CT-112 (3x daily, 20µl, Senju Pharmaceutical Co., Japan). Control & remaining half of the galactosemic animals received equivalent doses of saline eyedrops. Rats were restrained w/o medication during sensitivity measurements conducted w/ a Cochet-Bonnet Aesthesiometer mounted on a micromanipulator. The end of the filament (0.012mm dia.), which applied a mean pressure of 0.96 g/mm perpendicular to the corneal surface at center, was in the plane of focus of a slit-lamp biomicroscope. Measurements were conducted by two investigators which were masked to the treatment group. The average blink-responses from 10 consecutive stimuli to each cornea were expressed as a percent. Results: Mean (±SD) baseline corneal sensitivity in all groups were similar (CON 73%±11, GAL 71%±15, ARI 74%±16). Corneal sensitivity in the galactosemic rat was decreased (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sensitivity and specificity of the screening mode of the Humphrey-Welch Allyn frequency-doubling technology (FDT), Octopus tendency-oriented perimetry (TOP), and the Humphrey Swedish Interactive Threshold Algorithm (SITA)-fast (HSF) in patients with glaucoma. DESIGN: A comparative consecutive case series. METHODS: This was a prospective study which took place in the glaucoma unit of an academic department of ophthalmology. One eye of 70 consecutive glaucoma patients and 28 age-matched normal subjects was studied. Eyes were examined with the program C-20 of FDT, G1-TOP, and 24-2 HSF in one visit and in random order. The gold standard for glaucoma was presence of a typical glaucomatous optic disk appearance on stereoscopic examination, which was judged by a glaucoma expert. The sensitivity and specificity, positive and negative predictive value, and receiver operating characteristic (ROC) curves of two algorithms for the FDT screening test, two algorithms for TOP, and three algorithms for HSF, as defined before the start of this study, were evaluated. The time required for each test was also analyzed. RESULTS: Values for area under the ROC curve ranged from 82.5%-93.9%. The largest area (93.9%) under the ROC curve was obtained with the FDT criteria, defining abnormality as presence of at least one abnormal location. Mean test time was 1.08 ± 0.28 minutes, 2.31 ± 0.28 minutes, and 4.14 ± 0.57 minutes for the FDT, TOP, and HSF, respectively. The difference in testing time was statistically significant (P <.0001). CONCLUSIONS: The C-20 FDT, G1-TOP, and 24-2 HSF appear to be useful tools to diagnose glaucoma. The test C-20 FDT and G1-TOP take approximately 1/4 and 1/2 of the time taken by 24 to 2 HSF. © 2002 by Elsevier Science Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A biochip based on surface plasmon resonance was fabricated to detect prostate specific antigen-a1-antichymotrypsin (PSA-ACT complex) in both HBS buffer and human serum. To reduce non-specific binding and steric hindrance effect, the chemical surface of the sensor chips was constructed by using various oligo(ethylene glycol) mixtures of different molar ratios of HS(CH2)11(OCH2CH2)6OCH2COOH and HS(CH2)11(OCH2CH2)3OH. The self-assembled monolayers were biotinylated to facilitate the immobilization of streptavidin. Using the chip surfaces, PSA-ACT complex in HBS buffer and human serum was detected at 20.7 and 47.5 ng/ml by primary immunoresponse, respectively. However, the limit of detection could be simply enhanced by a sandwich strategy to improve the sensitivity and specificity of the immunoassay. An intact PSA polyclonal antibody was used as an amplifying agent in the strategy. As a result, PSA-ACT complex concentrations as low as 10.2 and 18.1 ng/ml were found in the HBS buffer and human serum sample, respectively. The result indicates that this approach could satisfy our goal without modifying the secondary interactant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a coupling of fluorophore-DNA barcode and bead-based immunoassay for detecting avian influenza virus (AIV) with PCR-like sensitivity is reported. The assay is based on the use of sandwich immunoassay and fluorophore-tagged oligonucleotides as representative barcodes. The detection involves the sandwiching of the target AIV between magnetic immunoprobes and barcode-carrying immunoprobes. Because each barcode-carrying immunoprobe is functionalized with a multitude of fluorophore-DNA barcode strands, many DNA barcodes are released for each positive binding event resulting in amplification of the signal. Using an inactivated H16N3 AIV as a model, a linear response over five orders of magnitude was obtained, and the sensitivity of the detection was comparable to conventional RT-PCR. Moreover, the entire detection required less than 2 hr. The results indicate that the method has great potential as an alternative for surveillance of epidemic outbreaks caused by AIV, other viruses and microorganisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we report a coupling of fluorophore-DNA barcode and bead-based
immunoassay for the detection of Avian Influenza Virus (AIV), a potential pandemic threat for human health and enormous economic losses. The detection strategy is based on the use of sandwich immunoassay and fluorophore-tagged oligonucleotides as representatively fluorescent barcodes. Despite its simplicity the assay has sensitivity comparable to RT-PCR amplification, and possesses a great potential as a rapid and sensitive on-chip detection format.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT (250 words)
BACKGROUND: The mechanism underlying respiratory virus-induced cough hypersensitivity is unknown. Up-regulation of airway neuronal receptors responsible for sensing physical and chemical stimuli is one possibility and the transient receptor potential (TRP) channel family are potential candidates. We have used an in vitro model of sensory neurones and human rhinovirus (HRV-16) to study the effect of virus infection on TRP expression.
METHODS: IMR32 neuroblastoma cells were differentiated in culture to express three TRP channels, TRPV1, TRPA1 and TRPM8. Flow cytometry and qRT-PCR were used to measure TRP channel protein and mRNA levels following inoculation with live virus, inactivated virus, virus- induced soluble factors or pelleted virus particles. Multiplex bioassay was used to determine nerve growth factor (NGF), interleukin (IL)-1ß, IL-6 and IL-8 levels in response to infection.
RESULTS: Early up-regulation of TRPA1 and TRPV1 expression occurred 2 to4 hours post infection. This was independent of replicating virus as virus induced soluble factors alone were sufficient to increase channel expression 50 and 15 fold, respectively. NGF, IL-6 and IL-8 levels, increased in infected cell supernatants, represent possible candidates. In contrast, TRPM8 expression was maximal at 48 hours (9.6 fold) and required virus replication rather than soluble factors
CONCLUSIONS We show for the first time that rhinovirus can infect neuronal cells. Furthermore, infection causes up-regulation of TRP channels by channel specific mechanisms. Increase in TRPA1 and TRPV1 levels can be mediated by soluble factors induced by infection whereas TRPM8 requires replicating virus. TRP channels may be novel therapeutic targets for controlling virus-induced cough.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While load flow conditions vary with different loads, the small-signal stability of the entire system is closely related with to the locations, capacities and models of loads. In this paper, load impacts with different capacities and models on the small-signal stability are analysed. In the real large-scale power system case, the load sensitivity which denotes the sensitivity of the eigenvalue with respect to the load active power is introduced and applied to rank the loads. The loads with high sensitivity are also considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims
Our aim was to test the prediction and clinical applicability of high-sensitivity assayed troponin I for incident cardiovascular events in a general middle-aged European population.

Methods and results
High-sensitivity assayed troponin I was measured in the Scottish Heart Health Extended Cohort (n = 15 340) with 2171 cardiovascular events (including acute coronary heart disease and probable ischaemic strokes), 714 coronary deaths (25% of all deaths), 1980 myocardial infarctions, and 797 strokes of all kinds during an average of 20 years follow-up. Detection rate above the limit of detection (LoD) was 74.8% in the overall population and 82.6% in men and 67.0% in women. Troponin I assayed by the high-sensitivity method was associated with future cardiovascular risk after full adjustment such as that individuals in the fourth category had 2.5 times the risk compared with those without detectable troponin I (P < 0.0001). These associations remained significant even for those individuals in whom levels of contemporary-sensitivity troponin I measures were not detectable. Addition of troponin I levels to clinical variables led to significant increases in risk prediction with significant improvement of the c-statistic (P < 0.0001) and net reclassification (P < 0.0001). A threshold of 4.7 pg/mL in women and 7.0 pg/mL in men is suggested to detect individuals at high risk for future cardiovascular events.

Conclusion
Troponin I, measured with a high-sensitivity assay, is an independent predictor of cardiovascular events and might support selection of at risk individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While on site measurement of air permeability provides a useful approach for assessing the likely long term durability of concrete structures, no existing test method is capable of effectively determining the relative permeability of high performance concrete (HPC). Lack of instrument sensitivity and the influence of concrete moisture are proposed as two key reasons for this phenomenon. With limited systematic research carried out in this area to date, the aim if this study was to investigate the influence of instrument sensitivity and moisture condition on air permeability measurements for both normal concrete and HPC. To achieve a range of moisture conditions, samples were dried initially for between one and 5 weeks and then sealed in polythene sheeting and stored in an oven at 50 C to internally distribute moisture evenly. Moisture distribution was determined throughout using relative humidity probe and electrical resistance measurements. Concrete air permeability was subsequently measured using standardised air permeability (Autoclam) and water penetration (BS EN: 12390-8) tests to assess differences between the HPCs tested in this study. It was found that for both normal and high performance concrete, the influence of moisture on Autoclam air permeability results could be eliminated by pre-drying (50 ± 1 C, RH 35%) specimens for 3 weeks. While drying for 5 weeks alone was found not to result in uniform internal moisture distributions, this state was achieved by exposing specimens to a further 3 weeks of sealed pre-conditioning at 50 ± 1 C. While the Autoclam test was not able to accurately identify relative HPC quality due to low sensitivity at associated performance levels, an effective preconditioning procedure to obtain reliable air permeability of HPC concretes was identified. © 2013 The Authors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article the multibody simulation software package MADYMO for analysing and optimizing occupant safety design was used to model crash tests for Normal Containment barriers in accordance with EN 1317. The verification process was carried out by simulating a TB31 and a TB32 crash test performed on vertical portable concrete barriers and by comparing the numerical results to those obtained experimentally. The same modelling approach was applied to both tests to evaluate the predictive capacity of the modelling at two different impact speeds. A sensitivity analysis of the vehicle stiffness was also carried out. The capacity to predict all of the principal EN1317 criteria was assessed for the first time: the acceleration severity index, the theoretical head impact velocity, the barrier working width and the vehicle exit box. Results showed a maximum error of 6% for the acceleration severity index and 21% for theoretical head impact velocity for the numerical simulation in comparison to the recorded data. The exit box position was predicted with a maximum error of 4°. For the working width, a large percentage difference was observed for test TB31 due to the small absolute value of the barrier deflection but the results were well within the limit value from the standard for both tests. The sensitivity analysis showed the robustness of the modelling with respect to contact stiffness increase of ±20% and ±40%. This is the first multibody model of portable concrete barriers that can reproduce not only the acceleration severity index but all the test criteria of EN 1317 and is therefore a valuable tool for new product development and for injury biomechanics research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clashes occur when components in an assembly unintentionally violate others. If clashes are not identified and designed out before manufacture, product function will be reduced or substantial cost will be incurred in rework. This paper introduces a novel approach for eliminating clashes by identifying which parameters defining the part features in a computer aided design (CAD) assembly need to change and by how much. Sensitivities are calculated for each parameter defining the part and the assembly as the change in clash volume due to a change in each parameter value. These sensitivities give an indication of important parameters and are used to predict the optimum combination of changes in each parameter to eliminate the clash. Consideration is given to the fact that it is sometimes preferable to modify some components in an assembly rather than others and that some components in an assembly cannot be modified as the designer does not have control over their shape. Successful elimination of clashes has been demonstrated in a number of example assemblies.