98 resultados para arterial stiffness


Relevância:

20.00% 20.00%

Publicador:

Resumo:

One way to restore physiological blood flow to occluded arteries involves the deformation of plaque using an intravascular balloon and preventing elastic recoil using a stent. Angioplasty and stent implantation cause unphysiological loading of the arterial tissue, which may lead to tissue in-growth and reblockage; termed “restenosis.” In this paper, a computational methodology for predicting the time-course of restenosis is presented. Stress-induced damage, computed using a remaining life approach, stimulates inflammation (production of matrix degrading factors and growth stimuli). This, in turn, induces a change in smooth muscle cell phenotype from contractile (as exists in the quiescent tissue) to synthetic (as exists in the growing tissue). In this paper, smooth muscle cell activity (migration, proliferation, and differentiation) is simulated in a lattice using a stochastic approach to model individual cell activity. The inflammation equations are examined under simplified loading cases. The mechanobiological parameters of the model were estimated by calibrating the model response to the results of a balloon angioplasty study in humans. The simulation method was then used to simulate restenosis in a two dimensional model of a stented artery. Cell activity predictions were similar to those observed during neointimal hyperplasia, culminating in the growth of restenosis. Similar to experiment, the amount of neointima produced increased with the degree of expansion of the stent, and this relationship was found to be highly dependant on the prescribed inflammatory response. It was found that the duration of inflammation affected the amount of restenosis produced, and that this effect was most pronounced with large stent expansions. In conclusion, the paper shows that the arterial tissue response to mechanical stimulation can be predicted using a stochastic cell modeling approach, and that the simulation captures features of restenosis development observed with real stents. The modeling approach is proposed for application in three dimensional models of cardiovascular stenting procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diabetes mellitus was induced in male beagles by a single injection of an alloxan and streptozotocin cocktail and fasting blood sugar levels maintained between 15 and 20 mmol/l. Five years after induction of diabetes, three diabetic animals were sacrificed, together with sex and age-matched controls, and the retinas fixed for either transmission electron microscopy (TEM) or trypsin digestion. In TEM specimens, capillaries in close proximity to the major vessels were designated as either AE (arterial environment) or VE (venous environment) and the thickness of their basement membranes (BMs) measured using an image analyser based two dimensional morphometric analysis system. Results show that the BMs of retinal capillaries from the diabetic dogs were significantly thicker than those from control dogs. Furthermore, within the diabetic group the AE capillaries had thicker BMs than VE capillaries (p less than or equal to 0.05). The controls, however, showed no significant difference in BM thickness between AE and VE capillaries. Although many of the capillaries designated as AE or VE would actually have been derived from the opposite side of the circulation, with respect to BM thickness, they conformed to values of their specific group. The conclusion is that diabetic capillaries are more vulnerable to BM thickening in an arterial environment than in a venous environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors have recently described a cold-formed steel portal framing system in which simple bolted moment-connections, formed through brackets, were used for the eaves and apex joints. Such connections, however, cannot be considered as rigid because of localised in-plane elongation of the bolt-holes caused by bearing against the bolt-shanks. To therefore predict the initial stiffness of such connections, it is necessary to know the initial bolt-hole elongation stiffness k(b). In this paper, a finite element-solid idealisation of a bolted lap joint in shear will be described that can be used to determine k(b); the results obtained are validated against experimental data. A beam idealisation of a cold-formed steel bolted moment-connection is then described, in which spring elements are used to idealise the rotational flexibility of the bolt-groups resulting from bolt-hole elongation: Using the value of k(b) in the beam idealisation, the deflections predicted are shown to be similar to those measured experimentally in laboratory tests conducted on the apex joint of a cold-formed steel portal frame. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analysis of non-traditional Variable Stiffness (VS) laminates, obtained by steering the fiber orientation as a spatial function of location, have shown to improve buckling load carrying capacity of flat rectangular panels under axial compressive loads. In some cases the buckling load of simply supported panels doubled compared to the best conventional laminate with straight fibers. Two distinct cases of stiffness variation, one due to fiber orientation variation in the direction of the loading, and the other one perpendicular to the loading direction, were identified as possible contributors to the buckling load improvements. In the first case, the increase was attributed to the favorable distribution of the transverse in-plane stresses over the panel platform. In the second case, a higher degree of improvement was obtained due to the re-distribution of the applied in-plane loads. Experimental results, however, showed substantially higher levels of buckling load improvements compared with theoretical predictions. The additional improvement was determined to be due to residual stresses introduced during curing of the laminates. The present paper provides a simplified thermomechanical analysis of residual stress state of variable stiffness laminates. Systematic parametric analyses of both cases of fiber orientation variations show that, indeed much higher buckling loads could result from the residual stresses present in such laminates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent research on Variable Stiffness (VS) laminates, which are constructed by steering the fiber orientation as a spatial function of location, have shown to improve laminate performance under mechanical loads. Two distinct cases of stiffness variation can be achieved either by variation of the fiber orientation in the direction of the global x-axis, or perpendicular to it. In the present paper, thermal analysis of a VS laminate is performed to study the effect of steering fibers on transient heat conduction under uniform heat flux using finite element method. The goal of the present paper is a parametric study of the effect of variable stiffness properties on transient response including time to reach steady state and temperature profile. Also, stress resultants and maximum stress location are investigated under different boundary conditions. A FEM algorithm is applied to exactly incorporate the boundary conditions for stress resultant analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent research on Variable Stiffness (VS) laminates, which are constructed by steering the fiber orientation as a spatial function of location, have shown to improve laminate performance under mechanical loads. Two distinct cases of stiffness variation can be achieved either by variation of the fiber orientation in the direction of the global x-axis, or perpendicular to it. In the present paper, thermal analysis of VS laminate is performed to study the effect of steering fibers on transient heat conduction under uniform heat flux using finite element method. The goal of the present paper is a parametric study of the
effect of variable stiffness properties on transient response including time to reach steady state and temperature profile. Also, stress resultants and maximum stress location are investigated under different boundary conditions. A FEM algorithm is applied to exactly incorporate the boundary conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This open learning zone article examines acid-base balance and the interpretation of arterial blood gases (ABG). The article begins with a brief revision of related physiology which leads on to the description of the primary disorders of acid-base balance. The normal ranges and the significance of abnormal ABG results are explored. The article concludes by providing an easy to follow 4 step guide to ABG interpretation with practice examples presented in the CPD task section.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments were performed to determine whether capacitative Ca(2+) entry (CCE) can be activated in canine pulmonary and renal arterial smooth muscle cells (ASMCs) and whether activation of CCE parallels the different functional structure of the sarcoplasmic reticulum (SR) in these two cell types. The cytosolic [Ca(2+)] was measured by imaging fura-2-loaded individual cells. Increases in the cytosolic [Ca(2+)] due to store depletion in pulmonary ASMCs required simultaneous depletion of both the inositol 1,4,5-trisphosphate (InsP(3))- and ryanodine (RY)-sensitive SR Ca(2+) stores. In contrast, the cytosolic [Ca(2+)] rises in renal ASMCs occurred when the SR stores were depleted through either the InsP(3) or RY pathways. The increase in the cytosolic [Ca(2+)] due to store depletion in both pulmonary and renal ASMCs was present in cells that were voltage clamped and was abolished when cells were perfused with a Ca(2+)-free bathing solution. Rapid quenching of the fura-2 signal by 100 microM Mn(2+) following SR store depletion indicated that extracellular Ca(2+) entry increased in both cell types and also verified that activation of CCE in pulmonary ASMCs required the simultaneous depletion of the InsP(3)- and RY-sensitive SR Ca(2+) stores, while CCE could be activated in renal ASMCs by the depletion of either of the InsP(3)- or RY-sensitive SR stores. Store depletion Ca(2+) entry in both pulmonary and renal ASMCs was strongly inhibited by Ni(2+) (0.1-10 mM), slightly inhibited by Cd(2+) (200-500 microM), but was not significantly affected by the voltage-gated Ca(2+) channel (VGCC) blocker nisoldipine (10 microM). The non-selective cation channel blocker Gd(3+) (100 microM) inhibited a portion of the Ca(2+) entry in 6 of 18 renal but not pulmonary ASMCs. These results provide evidence that SR Ca(2+) store depletion activates CCE in parallel with the organization of intracellular Ca(2+) stores in canine pulmonary and renal ASMCs.