112 resultados para arsenite, leiteite, reinerite, Raman Spectroscopy, single crystal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel method of obtaining high-quality Raman spectra of luminescent samples was tested using cyclohexane solutions which had been treated with a fluorescent dye. The method involves removing the fixed pattern irregularity found in the spectra taken with CCD detectors by subtracting spectra taken at several different, closely spaced spectrometer positions. It is conceptually similar to SERDS (shifted excitation Raman difference spectroscopy) but has the distinct experimental advantage that it does not require a tunable laser source. The subtracted spectra obtained as the raw data are converted into a more recognisable and conventional form by iterative fitting of appropriate double Lorentzian functions whose peak parameters are then used to 'reconstruct' a conventional representation of the spectrum. Importantly, it is shown that the degree of uncertainty in the resultant 'reconstructed' spectra can be gauged reliably by comparing reconstructed spectra obtained at two different spectrometer shifts (delta and 2 delta), The method was illustrated and validated using a solvent (cyclohexane) the spectrum of which is well known and which contains both regions with complex overlapping bands and regions with isolated bands, Possible sources of error are discussed and it is shown that, provided the degree of uncertainty in the data is correctly characterised, it is completely valid to draw conclusions about the spectra of the sample on the basis of the reconstructed data. The acronym SSRS (subtracted shifted Raman spectroscopy; pronounced scissors) is proposed for this method, to distinguish it from the SERDS technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vibrational Raman spectroscopy is now widely recognized as a useful technique for chemical analysis. It has become increasingly popular for the characterization of stable species since the technology which underpins Raman measurements has matured. Time-resolved Raman spectroscopy has also become established as an excellent method for the characterization of transient chemical species but it is not so widely applied. However, the technical advances which have reduced the cost and increased the reliability of conventional: Raman systems can also be exploited in studies of transient species. In some cases it is just as straightforward to record the Raman-spectra of a short-lived transient species as it is to monitor a more stable sample. This raises the possibility of routinely adding time-domain Raman measurements to more conventional Raman techniques, increasing the selectivity of the analysis while retaining its ability to provide spectral information which is characteristic of the species under investigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Time-resolved resonance Raman spectroscopy of the lowest energy excited state of the 4,4'-bipyridyl ligand-bridged complex, [(CO)(5)W(L)W(CO5] (1), and Raman spectroscopy of electrochemically reduced 1, both give bands characteristic of the the L(.-) species. This confirms that the ligand L is negatively charged in the lowest energy exicited state which is therefore metal-ligand charge transfer (MLCT) in character. Raman spectra of the radical anion of 1 excited in the far red (800 nm) exhibited a band near 2050 cm(-1) due to a vco symmetric CO stretching mode, compared to the corresponding band at 2070 cm(-1) in the spectrum of the parent, uncharged complex. The lower vco in the reduced complex supports the recent finding by time-resolved IR spectroscopy of a similar frequency decrease for nu(CO) in the longest lived (MLCT) excited state of 1 which was attributed to electron/hole localisation in this state on the IR time scale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resonance Raman spectra of the T-1 excited states of Zn and free-base tetra-4-sulfonatophenylporphyrin (TPPS) have been recorded at room temperature in aqueous solution using two-colour time-resolved methods. The spectra of both sulfonated molecules are very similar to their tetraphenylporphyrin (TPP) analogues, which have been recorded in THF solution using the same pump-probe conditions, but they have higher signal-to-noise ratios because interference from strong solvent bands is reduced. Although two different T-1 spectra of Zn(TPP) have been reported these spectra differ slightly from each other and from the spectrum reported here, which has band positions very close (+/-6 cm(-1)) to those of Zn(TPPS). The high S/N ratios obtainable for the water-soluble porphyrins have allowed reliable polarization data to be recorded for their S-0 and T-1 states. This data set allows a realistic comparison of the changes in bonding associated with excitation of both free-base and Zn tetraarylporphyrins to the T-1 state.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two-color time-resolved resonance Raman spectroscopy has been used to probe the lowest excited singlet (S1) and triplet (T1) states of free-base meso-tetraphenylporphyrin and meso-tetrakis(4-sulphonatophenyl)porphyrin in solution at room temperature. The spectra were recorded using 532-nm excitation pulses and time-delayed probe pulses (DELTAT = 0-30 ns, 447 and 460 nm) near lambda(max) of the S1 and T1 states. Significant shifts in frequency of the porphyrin core vibrations were observed upon excitation to either the S1 or T1 state. Several of the strongest polarized bands in the spectra of both excited states, including nu1, nu2, nu4, nu6, and phi4, are assigned, and the information they give on the differences in electron distribution in the ground, S1, and T1 states is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Raman spectroscopy is a noninvasive, nondestructive tool for capturing multiplexed biochemical information across diverse molecular species including proteins, lipids, DNA, and mineralizations. Based on light scattering from molecules, cells, and tissues, it is possible to detect molecular fingerprints and discriminate between subtly different members of each biochemical class. Raman spectroscopy is ideal for detecting perturbations from the expected molecular structure such as those occurring during senescence and the modification of long-lived proteins by metabolic intermediates as we age. Here, we describe the sample preparation, data acquisition, signal processing, data analysis and interpretation involved in using Raman spectroscopy for detecting age-related protein modifications in complex biological tissues.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The manner in which 90? ferroelectric-ferroelastic domains respond to changes in temperature has been mapped in BaTiO3 single crystals using atomic force microscopy. Domain periodicity remains unaltered until approximately 2 ? C below the Curie temperature (TC ), whereupon domains coarsened dramatically. This behavior was successfully rationalized by considering the temperature dependence of the parameters associated with standard models of ferroelastic domain formation. However, while successful in describing the expected radical increase in equilibrium period with temperature, the model did not predict the unusual mechanism by which domain coarsening occurred; this was not continuous at a local level but instead involved discrete domain annihilation events. Subsequent insights from a combination of free energy analysis for the system and further experimental data from an analogous situation, in which domain period increases with increasing crystal thickness, suggested that domain annihilation is inevitable whenever a component of the relevant gradient that affects domain period is orientated parallel to the domain walls. Consistent with this thesis, we note that, for the observations presented herein, the thermal gradient possessed a significant component parallel to the domain walls. We suggest that domain annihilation is a general feature of domain structures in gradient fields.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigates a model system for potential pharmaceutical materials in fluidised bed processes. In particular, this study proposes a novel use of Raman spectroscopy, which allows in situ measurement of the composition of the material within the fluidised bed in three spatial dimensions and as a function of time. This is achieved by recording Raman spectra from specific volumes of space. The work shows that Raman spectroscopy can be used to provide 3D maps of the concentration and chemical structure of the particles in a fluidised bed within a relatively short (120 s) time window. At the most basic level the technique measures particle density via the intensity of the Raman spectra, however this could be used. More importantly the data are also rich in spectroscopic information on the chemical structure of the fluidised particles which is useful either for monitoring a given granulation process or more generally for the analysis of the dynamics of the airflow if the data were incorporated into an appropriate model. The technique has the potential to give detailed in situ information on how the structure and composition of the granules/powders within the fluidised bed (dryer or granulator) vary with the position and evolve with time. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To separately investigate the impact of simulated age-related lens yellowing, transparency loss and refractive error on measurements of macular pigment (MP) using resonance Raman spectroscopy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To investigate whether two methods of measuring macular pigment-namely, heterochromatic flicker photometry (HFP) and resonance Raman spectroscopy (RRS)--yield comparable data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Naturally occurring boundaries between bundles of 90° stripe domains, which form in BaTiO3 lamellae on cooling through the Curie Temperature, have been characterized using both piezoresponse force microscopy (PFM) and scanning transmission electron microscopy (STEM). Detailed interpretation of the dipole configurations present at these boundaries (using data taken from PFM) shows that in the vast majority of cases they are composed of simple zigzag 180° domain walls. Topological information from STEM shows that occasionally domain bundle boundaries can support chains of dipole flux closure and quadrupole nanostructures, but these kinds of boundaries are comparatively rare; when such chains do exist, it is notable that singularities at the cores of the dipole
structures are avoided. The symmetry of the boundary shows that diads and centers of inversion exist at positions where core singularities should have been expected.