125 resultados para Semi-blind equalization
Resumo:
A systematic computational fluid dynamics (CFD) approach has been applied to design the geometry of the channels of a three-dimensional (thick-walled) screen comprising upstream and downstream sets of elongated channels positioned at an angle of 90 degrees with respect to each other. Such a geometry of the thick-wall screen can effectively drop the ratio of the maximum flow velocity to mean flow velocity below 1.005 in a downstream microstructured reactor at low Reynolds numbers. In this approach the problem of flow equalization reduces to that of flow equalization in the first and second downstream channels of the thick-walled screen. In turn, this requires flow equalization in the corresponding cross-sections of the upstream channels. The validity of the proposed design method was assessed through a case study. The effect of different design parameters on the flow non-uniformity in the downstream channels has been established. The design equation is proposed to calculate the optimum values of the screen parameters. The CFD results on flow distribution were experimentally validated by Laser Doppler Anemometry measurements in the range of Reynolds numbers from 6 to 113. The measured flow non-uniformity in the separate reactor channels was below 2%.
Resumo:
To enhance the uniformity of fluid flow distribution in microreactors, a header configuration consisting of a cone diffuser connected to a thick-walled screen has been proposed. The thick-walled screen consists of two sections: the upstream section constitutes a set of elongated parallel upstream channels and the downstream section constitutes a set of elongated parallel downstream channels positioned at an angle of 90 with respect to the upstream channels. In this approach the problem of flow, equalization reduces to that of flow equalization in the first and second downstream channels of the thick-walled screen. In turn, this requires flow equalization in the corresponding cross sections of the upstream channels. The computational fluid dynamics analysis of the fluid flow maldistribution shows that eight parallel upstream channels with a width of 300-600 pm are required per 1 cm of length for flow equalization. The length to width ratio of these channels has to be > 15. The numerical results suggest that the proposed header-configuration can effectively improve the performance of the downstream microstructured devices, decreasing the ratio of the maximum flow velocity to the mean flow velocity from 2 to 1.005 for a wide range of Reynolds numbers (0.5-10). 2006 American Institute of Chemical Engineers AlChE J, 53: 28-38, 2007.
Resumo:
Purpose. This study examined the viscoelastic properties of bioadhesive, chlorhexidine-containing semi-solid formulations, designed for topical application to the oropharynx.
Resumo:
The present study proposed the semi-empirical methods for determining the efflux velocity from a ship's propeller. Ryan [1] defined the efflux velocity as the maximum velocity taken from a time-averaged velocity distribution along the initial propeller plane. The Laser Doppler Anemometry (LDA) and Computational Fluid Dynamics (CFD) were used to acquire the efflux velocity from the two propellers with different geometrical characteristics. The LDA and CFD results were compared in order to investigate the equation derived from the axial momentum theory. The study confirmed the validation of the axial momentum theory and its linear relationship between the efflux velocity and the multiplication of the rotational speed, propeller diameter and the square root of thrust coefficient. The linear relationship of these two terms is connected by an efflux coefficient and the value of this efflux coefficient reduced when the blade number increased.
Resumo:
Details are given of a cold-formed steel portal framing system that uses simple bolted moment-connections for both the eaves and apex joints. However, such joints function as semi-rigid and, as a result, the design of the proposed system will be dominated by serviceability requirements. While serviceability is a mandatory design requirement, actual deflection limits for portal frames are not prescribed in many of the national standards. In this paper, a review of the design constraints that have an effect on deflection limits is discussed, and rational values appropriate for use with cold-formed steel portal frames are recommended. Adopting these deflection limits, it is shown through a design example how a cold-formed steel portal frame having semi-rigid eaves and apex joints can be a feasible alternative to rigid-jointed frames in appropriate circumstances.
Resumo:
There are few data on the role of prokinetic agents as maintenance therapy in moderately severe reflux oesophagitis despite the high relapse rate of this condition after healing.
Resumo:
At least 10-15% of patients with reflux symptoms have a normal endoscopy and physiological levels of acid reflux on pH monitoring. Such patients with 50% or more of symptoms associated with acid reflux episodes have "a positive symptom index" (SI), and it has been proposed that this defines the "sensitive oesophagus".
Resumo:
Thermoresponsive polymeric platforms are used to optimise drug delivery in pharmaceutical systems and bioactive medical devices. However, the practical application of these systems is compromised by their poor mechanical properties. This study describes the design of thermoresponsive semi-interpenetrating polymer networks (s-IPNs) based on cross-linked p(NIPAA) or p(NIPAA-co-HEMA) hydrogels containing poly(e-caprolactone) designed to address this issue. Using DSC, the lower critical solution temperature of the co-polymer and p(NIPAA) matrices were circa 34 °C and 32 °C, respectively. PCL was physically dispersed within the hydrogel matrices as confirmed using confocal scanning laser microscopy and DSC and resulted in marked changes in the mechanical properties (ultimate tensile strength, Young's modulus) without adversely compromising the elongation properties. P(NIPAA) networks containing dispersed PCL exhibited thermoresponsive swelling properties following immersion in buffer (pH 7), with the equilibrium-swelling ratio being greater at 20 °C than 37 °C and greatest for p(NIPAA)/PCL systems at 20 °C. The incorporation of PCL significantly lowered the equilibrium swelling ratio of the various networks but this was not deemed practically significant for s-IPNs based on p(NIPAA). Thermoresponsive release of metronidazole was observed from s-IPN composed of p(NIPAA)/PCL at 37 °C but not from p(NIPAA-co-HEMA)/PCL at this temperature. In all other platforms, drug release at 20 °C was significantly similar to that at 37 °C and was diffusion controlled. This study has uniquely described a strategy by which thermoresponsive drug release may be performed from polymeric platforms with highly elastic properties. It is proposed that these materials may be used clinically as bioactive endotracheal tubes, designed to offer enhanced resistance to ventilator associated pneumonia, a clinical condition associated with the use of endotracheal tubes where stimulus responsive drug release from biomaterials of significant mechanical properties would be advantageous. © 2012 Elsevier B.V. All rights reserved.
Resumo:
Mild hyperhomocysteinemia is accepted as a risk factor for premature cardiovascular disease. In a population with a high prevalence of cardiovascular disease, we screened a group of clinically healthy working men aged 30-49 y (n = 509) for plasma homocysteine and 5,10-methylene tetrahydrofolate reductase (MTHFR) genotype status. Those with mildly elevated homocysteine concentrations (> or = 8.34 micromol/L) were selected for intervention. In a randomized, factorial-design, controlled trial we assessed the effects of B-group vitamins and antioxidant vitamin supplementation on homocysteine concentrations. The 132 men were randomly assigned to one of four groups: supplementation with B-group vitamins alone (1 mg folic acid, 7.2 mg pyridoxine, and 0.02 mg cyanocobalamin), antioxidant vitamins alone (150 mg ascorbic acid, 67 mg RRR-alpha-tocopherol, and 9 mg beta-carotene), B-group vitamins with antioxidant vitamins, or placebo. Intervention was double-blind. A total of 101 men completed the 8-wk intervention. When homocysteine concentrations were analyzed by group, significant (P <0.001) decreases (32.0% and 30.0%, respectively) were observed in both groups receiving B-group vitamins either with or without antioxidants. The effect of B-group vitamins alone over 8 wk was a reduction in homocysteine concentrations of 27.9% (95% CI: 22.0%, 33.3%; P <0.001) whereas antioxidants alone produced a nonsignificant increase of 5.1% (95% CI: -2.8%, 13.6%; P = 0.21). There was no evidence of any interaction between the two groups of vitamins. The effect of B-group vitamin supplementation seemed to depend on MTHFR genotype. Supplementation with the B-group vitamins with or without antioxidants reduced homocysteine in the men with mildly elevated concentrations, and hence may be effective in reducing cardiovascular risk.
Resumo:
Evidence supports the use of exercise for chronic low back pain (CLBP); however, adherence is often poor due to ongoing pain. Auricular acupuncture is a form of pain relief involving the stimulation of points on the outer ear corresponding with specific body parts. It may be a useful adjunct to exercise in managing CLBP; however, there is only limited evidence to support its use with this patient group.