134 resultados para SENSORY DEVICE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Consistency in target organ and organ at risk position from planning to treatment is an important basic principle of radiotherapy. This study evaluates the effectiveness of bladder-filling instructions in achieving a consistent and reproducible bladder volume at the time of planning CT and daily during the course of radical radiotherapy for prostate cancer. It also assessed the rate of bladder filling before and at the end of radiotherapy.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrochemical capacitors, also known as supercapacitors, are becoming increasingly important components in energy storage, although their widespread use has not been attained due to a high cost/ performance ratio. Fundamental research is contributing to lowered costs through the engineering of new materials. Currently the most viable materials used in electrochemical capacitors are biomassderived and polymer-derived activated carbons, although other carbon materials are useful research tools. Metal oxides could result in a step change for electrochemical capacitor technology and is an exciting area of research. The selection of an appropriate electrolyte and electrode structure is fundamental in determining device performance. Although there are still many uncertainties in understanding the underlying mechanisms involved in electrochemical capacitors, genuine progress continues to be made. It is argued that a large, collaborative international research programme is necessary to fully develop the potential of electrochemical capacitors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The identification of the sensory cues and mechanisms by which migratory birds are able to reach the same breeding and wintering grounds year after year has eluded biologists despite more than 50 years of intensive study. While a number of environmental cues have been proposed to play a role in the navigation of birds, arguments still persist about which cues are essential for the experience based navigation shown by adult migrants. To date, few studies have tested the sensory basis of navigational cues used during actual migration in the wild: mainly laboratory based studies or homing during the non-migratory season have been used to investigate this behaviour. Here we tested the role of olfactory and magnetic cues in the migration of the catbird (Dumetella carolinensis) by radio tracking the migration of birds with sensory manipulations during their actual migratory flights. Our data suggest that adult birds treated with zinc sulphate to produce anosmia were unable to show the same orientation as control adults, and instead reverted to a direction similar to that shown by juveniles making their first migration. The magnetic manipulation had no effect on the orientation of either adults or juveniles. These results allow us to propose that the olfactory sense may play a role in experience based migration in adult catbirds. While the olfactory sense has been shown to play a role in the homing of pigeons and other birds, this is the first time it has been implicated in migratory orientation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The megachiropteran fruit bat Rousettus aegyptiacus is able to orient and navigate using both vision and echolocation. These two sensory systems have different environmental constraints however, echolocation being relatively short range when compared with vision. Despite this difference, an experiment testing their memory of a perch location demonstrates that once the location of a perch is learned R. aegyptiacus is not influenced by the movement of local landmark cues in the vicinity of the perch under either light or dark conditions. Thus despite the differing constraints of vision and echolocation, this suggests a place is remembered as a location in space and not by associations with landmarks in the vicinity. A decrease in initial performance when the task was repeated in the dark suggested the possibility that a memory of a location learned using vision does not generalize to echolocation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In older adults, cognitive resources play a key role in maintaining postural stability. In the present study, we evaluated whether increasing postural instability using sway referencing induces changes in resource allocation in dual-task performance leading older adults to prioritize the more age-salient posture task over a cognitive task. Young and older adults participated in the study which comprised two sessions. In the first session, three posture tasks (stable, sway reference visual, sway reference somatosensory) and a working memory task (n-back) were examined. In the second session, single- and dual-task performance of posture and memory were assessed. Postural stability improved with session. Participants were more unstable in the sway reference conditions, and pronounced age differences were observed in the somatosensory sway reference condition. In dual-task performance on the stable surface, older adults showed an almost 40% increase in instability compared to single-task. However, in the sway reference somatosensory condition, stability was the same in single- and dual-task performance, whereas pronounced (15%) costs emerged for cognition. These results show that during dual-tasking while standing on a stable surface, older adults have the flexibility to allow an increase in instability to accommodate cognitive task performance. However, when instability increases by means of compromising somatosensory information, levels of postural control are kept similar in single- and dual-task, by utilizing resources otherwise allocated to the cognitive task. This evidence emphasizes the flexible nature of resource allocation, developed over the life-span to compensate for age-related decline in sensorimotor and cognitive processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The core difficulty in developmental dyslexia across languages is a "phonological deficit", a specific difficulty with the neural representation of the sound structure of words. Recent data across languages suggest that this phonological deficit arises in part from inefficient auditory processing of the rate of change of the amplitude envelope at syllable onset (inefficient sensory processing of rise time). Rise time is a complex percept that also involves changes in duration and perceived intensity. Understanding the neural mechanisms that give rise to the phonological deficit in dyslexia is important for optimising educational interventions. In a three-deviant passive 'oddball' paradigm and a corresponding blocked 'deviant-alone' control condition we recorded ERPs to tones varying in rise time, duration and intensity in children with dyslexia and typically developing children longitudinally. We report here results from test Phases 1 and 2, when participants were aged 8-10. years. We found an MMN to duration, but not to rise time nor intensity deviants, at both time points for both groups. For rise time, duration and intensity we found group effects in both the Oddball and Blocked conditions. There was a slower fronto-central P1 response in the dyslexic group compared to controls. The amplitude of the P1 fronto-centrally to tones with slower rise times and lower intensity was smaller compared to tones with sharper rise times and higher intensity in the Oddball condition, for children with dyslexia only. The latency of this ERP component for all three stimuli was shorter on the right compared to the left hemisphere, only for the dyslexic group in the Blocked condition. Furthermore, we found decreased N1c amplitude to tones with slower rise times compared to tones with sharper rise times for children with dyslexia, only in the Oddball condition. Several other effects of stimulus type, age and laterality were also observed. Our data suggest that neuronal responses underlying some aspects of auditory sensory processing may be impaired in dyslexia. © 2011 Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medical device related infections are becoming an increasing prevalent area of infectious disease. They can be attributed to a multitude of factors from an increasing elderly population with reduced immunological status to increasing microbial resistance and evolution. Of greatest significance is the failure of standard antimicrobial regimens to eradicate biomaterial-related infections due to the formation of microbial biofilms consisting of extracellular polymeric substances. Biofilms form and thrive at the abiotic device surface where nutrients are more concentrated and symbiotic colonies can be formed. The formation of a biofilm matrix occurs in a series of steps beginning with reversible attachment of bacteria to the surface of the substrate and terminating in dispersion of mature biofilm microcolonies that aim to colonise fresh surfaces high in nutrients. Mature biofilms can resist 10-1000 times the concentrations of standard antibiotic regimens that are required to kill genetically equivalent planktonic forms. The extent of the infection and the pathogen(s) present can be attributed to both the form and location of the device. It is important that preventative measures and treatment strategies relate to combating the causative microorganisms. Preventative measures include: the use of anti-infective biomaterials that can be coated or incorporated with standard or innovative antimicrobials; modified anti-adhesive medical devices; environmental sterilisation protocols and prophylactic drug therapy. Treatment of established infection may require removal of the device or if deemed possible the device may be salvageable through the initiation of antimicrobial therapy. The increasing spectre of antibiotic resistance and medical device related infections are a large and increasing burden on health care systems and the patient’s quality of life and long term prognosis. As an infectious disease it represents one of the most difficult challenges facing modern science and healthcare.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we have shown that a 100 MHz Love wave device can be used to determine whether room temperature ionic liquids (RTILs) are Newtonian fluids and have developed a technique that allows the determination of the density-viscosity product, rho eta of a Newtonian RTIL. In addition, a test for a Newtonian response was established by relating the phase change to insertion loss change. Five concentrations of a water-miscible RTIL and seven pure RTILs were measured. The changes in phase and insertion loss were found to vary linearly with the square root of the density-viscosity product for values up to (rho eta)(1/2) similar to 10 kg m(-2) s(-1/2). The square root of the density-viscosity product was deduced from the changes in either phase or insertion loss using glycerol as a calibration liquid. In both cases, the deduced values of rho eta agree well with those measured using viscosity and density meters. Miniaturization of the device, beyond that achievable with the lower-frequency quartz crystal microbalance approach, to measure smaller volumes is possible. The ability to fabricate Love wave and other surface acoustic wave sensors using planar metallization technologies gives potential for future integration into lab-on-a-chip analytical systems for characterizing ionic liquids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The eluent droplet size defines the number of sampling compartments in a continuously operated annular electrochromatograph and therefore influences separation efficiency. In this work, an assembly of two capillaries, a feeding capillary on the top and a receiving capillary placed under it, has been investigated to control droplet size. The receiving capillary prevents the liquid droplet formation beyond a critical size, which reduces the volume of sampling compartment as compared with the case of the electrolyte flow driven solely by gravity. With a receiving capillary, the electrolyte droplet size was reduced from 1.5 to 0.46 mm. Further decrease of droplet size was not possible due to a so-called droplet jump upwards effect which has been observed on a hydrophilic glass surface with water. A typical electrolyte used in CAEC has high methanol content. In an attempt to improve the methanol-repellent properties of the glass surface, two approaches have been implemented: (i) self-assembled chemisorbed monolayers of an alkylsiloxane and (ii) fabrication of a nano-pin film. The methanol-repellent surface of the feeding capillary suppressed the droplet jump upwards effect. The surface remained methanol repellent in different solutions with lower polarity than that of water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review will summarize the significant body of research within the field of electrical methods of controlling the growth of microorganisms. We examine the progress from early work using current to kill bacteria in static fluids to more realistic treatment scenarios such as flow-through systems designed to imitate the human urinary tract. Additionally, the electrical enhancement of biocide and antibiotic efficacy will be examined alongside recent innovations including the biological applications of acoustic energy systems to prevent bacterial surface adherence. Particular attention will be paid to the electrical engineering aspects of previous work, such as electrode composition, quantitative electrical parameters and the conductive medium used. Scrutiny of published systems from an electrical engineering perspective will help to facilitate improved understanding of the methods, devices and mechanisms that have been effective in controlling bacteria, as well as providing insights and strategies to improve the performance of such systems and develop the next generation of antimicrobial bioelectric materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports the physicochemical and drug diffusion properties of rifampicin containing poly(epsilon-caprolactone) (PCL)/polyethylene glycol (PEG) networks, designed as bioactive biomaterials. Uniquely, the effects of the states of both rifampicin and PEG and the interplay between these components on these properties are described. PCL matrices containing rifampicin (1-5%, w/w) and PEG 200 (0-15%, w/w) were prepared by casting from an organic solvent (dichloromethane). The films were subsequently characterized in terms of their thermal/thermorheological, surface and tensile properties, biodegradation and drug diffusion/release properties. Incorporation of PEG and/or rifampicin significantly affected the tensile and surface properties of PCL, lowering the ultimate tensile strength, % elongation at break, Young modulus and storage and loss moduli. Both in the absence and presence of PEG, solubilisation of rifampicin within the crystalline domains of PCL was observed. PEG was present as a dispersed liquid phase. The release of rifampicin (3% loading) was unaffected by the presence of PEG. Similarly the release of rifampicin (5%) was unaffected by low concentrations of PEG (5-10%) however, at higher loadings, the release rate of rifampicin was enhanced by the presence of PEG. Rifampicin release (10% loading) was enhanced by the presence of PEG in a concentration dependent fashion. These observations were accredited to enhanced porosity of the matrix. In all cases, diffusion-controlled release of rifampicin occurred which was unaffected by polymer degradation. This study has uniquely illustrated the effect of hydrophilic pore formers on the physicochemical properties of PCL. Interestingly, enhanced diffusion controlled release was only observed from biomaterials containing high loadings of PEG and rifampicin (5, 10%), concentrations that were shown to affect the mechanical properties of the biomaterials. Care should therefore be shown when adopting this strategy to enhance release of bioactive agents from biomaterials. (C) 2011 Elsevier B.V. All rights reserved.