81 resultados para Reagents indicator


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, there has been a move towards the development of indirect structural health monitoring (SHM)techniques for bridges; the low-cost vibration-based method presented in this paper is such an approach. It consists of the use of a moving vehicle fitted with accelerometers on its axles and incorporates wavelet analysis and statistical pattern recognition. The aim of the approach is to both detect and locate damage in bridges while reducing the need for direct instrumentation of the bridge. In theoretical simulations, a simplified vehicle-bridge interaction model is used to investigate the effectiveness of the approach in detecting damage in a bridge from vehicle accelerations. For this purpose, the accelerations are processed using a continuous wavelet transform as when the axle passes over a damaged section, any discontinuity in the signal would affect the wavelet coefficients. Based on these coefficients, a damage indicator is formulated which can distinguish between different damage levels. However, it is found to be difficult to quantify damage of varying levels when the vehicle’s transverse position is varied between bridge crossings. In a real bridge field experiment, damage was applied artificially to a steel truss bridge to test the effectiveness of the indirect approach in practice; for this purpose a two-axle van was driven across the bridge at constant speed. Both bridge and vehicle acceleration measurements were recorded. The dynamic properties of the test vehicle were identified initially via free vibration tests. It was found that the resulting damage indicators for the bridge and vehicle showed similar patterns, however, it was difficult to distinguish between different artificial damage scenarios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The monitoring of oral disease is important, not alone for oral health, but for the detection and prevention of
systemic disease. The link between oral health and systemic disease is the focus of many studies, with
indications emerging of a causal link [1]. For disease diagnostics, blood has typically been the fluid of choice
for analysis, the retrieval of which is invasive and therefore unsuitable for wearable technology. Analysis of
saliva, however, is less invasive than that of blood, requires little or no pre-treatment and is abundantly
available. A strong correlation has been found between the analytes of blood and saliva [2] with saliva
containing biomarkers for diseases such as diabetes, oral cancer and cardiovascular disease. The development of
an implantable multi-parametric wireless sensor, to monitor both salivary analytes and changes in gingival
temperature, is the aim of this research project.
The aim of our current study is to detect changes in salivary pH, using a gold electrode with a pHsensitive
iridium oxide layer, and an Ion Sensitive Field Effect Transistor probe. Characterisation studies were
carried out in artificial saliva (AS). A salivary pH of between 4.5pH-7.5pH [3], and gingival temperature
between 35°C-38°C [4], were identified as the target range of interest for the human oral environment. Sensor
measurements were recorded in solutions of varying pH and temperature. An ISFET probe was then implanted
into a prototype denture and characterised in AS. This study demonstrates the suitability of ISFET and gold
electrode pH sensors for incorporation into implantable oral sensors.
[1] G. Taylor and W. Borgnakke, “Periodontal disease: associations with diabetes, glycemic control and
complications,” Oral Dis., vol. 14, no. 3, pp. 191–203, Apr. 2008.
[2] E. Tékus, M. Kaj, E. Szabó, N. L. Szénási, I. Kerepesi, M. Figler, R. Gábriel, and M. Wilhelm,
“Comparison of blood and saliva lactate level after maximum intensity exercise,” Acta Biol. Hung., vol. 63
Suppl 1, pp. 89–98, 2012.
[3] S. Naveen, M. L. Asha, G. Shubha, A. Bajoria, and A. Jose, “Salivary Flow Rate, pH and Buffering
Capacity in Pregnant and Non Pregnant Women - A Comparative Study,” JMED Res., pp. 1–8, Feb. 2014.
[4] A. F. Holthuis and F. S. Chebib, “Observations on temperature and temperature patterns of the gingiva. I.
The effect of arch, region and health,” J. Periodontol., vol. 54, no. 10, pp. 624–628, Oct. 1983

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genuine Savings has emerged as a widely used indicator of sustainable development. In this paper, we use long -term data stretching back to 1870 to undertake empirical tests of the relationship between Genuine Savings (GS) and future well-being for three countries: Britain, the USA and Germany. Our tests are based on an underlying theoretical relationship between GS and changes in the present value of future consumption. Based on both single country and panel results, we find evidence supporting the existence of javascript:void(0);a cointegrating (long run equilibrium) relationship between GS and future well-being, and fail to reject the basic theoretical result on the relationship between these two macroeconomic variables. This provides some support for the GS measure of weak sustainability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three photocatalyst inks based on the redox dyes, Resazurin (Rz), Basic Blue 66 (BB66) and Acid Violet 7 (AV7), are used to assess the photocatalytic activities of a variety of different materials, such as commercial paint, tiles and glass and laboratory made samples of sol–gel coated glass and paint, which collectively exhibit a wide range of activities that cannot currently be probed by any one of the existing ISO tests. Unlike the ISO tests, the ink tests are fast (typically <10 min), simple to employ and inexpensive. Previous work indicates that the Rz ink test at least correlates linearly with other photocatalytic tests such as the photomineralisation of stearic acid. The average time to bleach 90% of the key RGB colour component of the ink, red for Rz and BB66 inks and green for AV7 ink, is determined, ttb(90), for eight samples of each of the different materials tested. Five laboratories conducted the tests and the results revealed an average repeatability and reproducibility of: ca. 11% and ca 21%, respectively, which compare well with those reported for the current ISO tests. Additional work on commercial self-cleaning glass using an Rz ink showed that the change in the red component of the RGB image of the ink correlated linearly with that of the change of absorbance at 608 nm, as measured using UV/vis spectroscopy, and the change in the a* component of the Lab colour analysis of the ink, as measured using diffuse reflectance spectroscopy. As a consequence, all three methods generate the same ttb(90). The advantages of the RGB digital image analysis method are discussed briefly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A resazurin (Rz) based photocatalyst activity indicator ink (paii) is used to test the activity of commercial self-cleaning materials. The semiconductor photocatalyst driven colour change of the ink is monitored indoors and outside using a simple mobile phone application that measures the RGB colour components of the digital image of the paii-covered, irradiated sample in real time. The results correlate directly with those generated using a traditional, lab-bound method of analysis (UV–vis spectrophotometry).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although Chronic Myeloid Leukaemia (CML) can be treated successfully with allogeneic bone marrow transplantation (BMT), leukaemia relapse remains a significant clinical problem. Molecular monitoring of the post transplant marrow can be useful in predicting relapse particularly in CML patients where the Philadelphia chromosome or its molecular counterpart, the BCR-ABL fusion messenger RNA can be used as a leukaemia specific marker of minimal residual disease (MRD). We have investigated chimaerism (using polymerase chain reaction of short tandem repeat sequences (STR-PCR)) and MRD status (using reverse transcriptase PCR of the BCR-ABL fusion mRNA) in a serial fashion in 18 patients who were in clinical and haematological remission post allogeneic BMT for chronic phase CML. Eleven patients exhibited complete donor chimaerism with no evidence of minimal residual disease. Five patients had transient or low level stable MC. Late MC and MRD was observed in two patients who relapsed > 6 years after T cell depleted BMT for CML. Thus STR-PCR is an appropriate screening test in the post transplant setting for CML patients, but those patients exhibiting mixed haemopoietic chimaerism should also be monitored using a leukaemia specific sensitive molecular assay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An 8-year-old girl with some features of Turner syndrome and karyotype 45X/46XY had developed a bilateral gonadoblastoma in her rudimentary ovaries. Her normal Y chromosome showed the characteristic distal fluorescence, as seen in her father's. Another mosaic, this time 45X/46XidicY, and also with some Turner features had rudimentary ovaries, but no gonadoblastoma had developed at age 14. The nature of her idicY, which showed no fluorescent distal Yq and had one of the centromeres inactivated, was confirmed by in situ hybridisation with a Yp-specific probe. Using primers from a human Yp-specific sequence, we amplified DNA extracted from paraffin-embedded ovarian tissue from both cases, and from a normal testicle and a normal ovary as controls. The finding of the expected Y-derived PCR product in the rudimentary gonads from these mosaic patients indicates the presence of their Y chromosome in both. We discuss the validity of the findings, and the possible role of sequences in or near the fluorescent part of Yq in the origin of gonadoblastoma in Y-bearing mosaic Turner syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the problem of regulating the rate of harvesting a natural resource, taking account of the wider system represented by a set of ecological and economic indicators, given differing stakeholder priorities. This requires objective and transparent decision making to show how indicators impinge on the resulting regulation decision. We offer a new scheme for combining indicators, derived from assessing the suitability of lowering versus not lowering the harvest rate based on indicator values relative to their predefined reference levels. Using the practical example of fisheries management under an “ecosystem approach,” we demonstrate how different stakeholder views can be quantitatively represented by weighting sets applied to these comparisons. Using the scheme in an analysis of historical data from the Celtic Sea fisheries, we find great scope for negotiating agreement among disparate stakeholders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Highly-sensitive optical fluorescent extruded plastic films are reported for the detection of gaseous and dissolved CO2. The pH-sensitive fluorescent dye used is 8-Hydroxypyrene-1,3,6-trisulfonic acid trisodium salt (HPTS, PTS-) coated on the surface of hydrophilic fumed silica and the base is tetrabutylammonium hydroxide (TBAH). The above components are used to create an HPTS pigment (i.e. HPTS/SiO2/TBAH) with a high CO2 sensitivity (%CO2(S=1/2) = 0.16%) and fast 50% response (t50↓) = 2 s and recovery (t50↑) = 5 s times. Highly CO2-sensitive plastic films are then fabricated, via the extrusion of the HPTS pigment powder in low-density polyethylene (LDPE). As with the HPTS-pigment, the luminescence intensity (at 515 nm) and absorbance (at 475 nm) of the HPTS plastic film decreases as the %CO2 in the ambient gas phase increases. The HPTS plastic film exhibits a high CO2 sensitivity, %CO2(S=1/2), of 0.29%, but a response time ˂2 min and recovery time ˂40 min, which is slower than that of the HPTS pigment. The HPTS plastic film is very stable under ambient conditions, (with a shelf life ˃ six month when stored in the dark but under otherwise ambient conditions). Moreover, the HPTS-film is stable in water, salt solution and even in acid (pH=2), and in each of these media it can be used to detect dissolved CO2.