79 resultados para Radial nerve


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adverse conditions prenatally increase the risk of cardiovascular disease, including hypertension. Chronic hypoxia in utero (CHU) causes endothelial dysfunction, but whether sympathetic vasoconstrictor nerve functioning is altered is unknown. We, therefore, compared in male CHU and control (N) rats muscle sympathetic nerve activity, vascular sympathetic innervation density, and mechanisms of sympathetic vasoconstriction. In young (Y)-CHU and Y-N rats (≈3 months), baseline arterial blood pressure was similar. However, tonic muscle sympathetic nerve activity recorded focally from arterial vessels of spinotrapezius muscle had higher mean frequency in Y-CHU than in Y-N rats (0.56±0.075 versus 0.33±0.036 Hz), and the proportions of single units with high instantaneous frequencies (1–5 and 6–10 Hz) being greater in Y-CHU rats. Sympathetic innervation density of tibial arteries was ≈50% greater in Y-CHU than in Y-N rats. Increases in femoral vascular resistance evoked by sympathetic stimulation at low frequency (2 Hz for 2 minutes) and bursts at 20 Hz were substantially smaller in Y-CHU than in Y-N rats. In Y-N only, the neuropeptide Y Y1-receptor antagonist BIBP3226 attenuated these responses. By contrast, baseline arterial blood pressure was higher in middle-aged (M)-CHU than in M-N rats (≈9 months; 139±3 versus 126±3 mmHg, respectively). BIBP3226 had no effect on femoral vascular resistance increases evoked by 2 Hz or 20 Hz bursts in M-N or M-CHU rats. These results indicate that fetal programming induced by prenatal hypoxia causes an increase in centrally generated muscle sympathetic nerve activity in youth and hypertension by middle age. This is associated with blunting of sympathetically evoked vasoconstriction and its neuropeptide Y component that may reflect premature vascular aging and contribute to increased risk of cardiovascular disease

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel model-based principal component analysis (PCA) method is proposed in this paper for wide-area power system monitoring, aiming to tackle one of the critical drawbacks of the conventional PCA, i.e. the incapability to handle non-Gaussian distributed variables. It is a significant extension of the original PCA method which has already shown to outperform traditional methods like rate-of-change-of-frequency (ROCOF). The ROCOF method is quick for processing local information, but its threshold is difficult to determine and nuisance tripping may easily occur. The proposed model-based PCA method uses a radial basis function neural network (RBFNN) model to handle the nonlinearity in the data set to solve the no-Gaussian issue, before the PCA method is used for islanding detection. To build an effective RBFNN model, this paper first uses a fast input selection method to remove insignificant neural inputs. Next, a heuristic optimization technique namely Teaching-Learning-Based-Optimization (TLBO) is adopted to tune the nonlinear parameters in the RBF neurons to build the optimized model. The novel RBFNN based PCA monitoring scheme is then employed for wide-area monitoring using the residuals between the model outputs and the real PMU measurements. Experimental results confirm the efficiency and effectiveness of the proposed method in monitoring a suite of process variables with different distribution characteristics, showing that the proposed RBFNN PCA method is a reliable scheme as an effective extension to the linear PCA method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The radial vaneless diffuser, though comparatively simple in terms of geometry, poses a significant challenge in obtaining an accurate 1-D based performance prediction due to the swirling, unsteady and distorted nature of the flow field. Turbocharger compressors specifically, with the ever increasing focus on achieving a wide operating range, have been recognised to operate with significant regions of spanwise separated flow, particularly at off-design conditions.

Using a combination of single passage Computational Fluid Dynamics (CFD) simulations and extensive gas stand test data for three geometries, the current study aims to evaluate the onset and impact of spanwise aerodynamic blockage in radial vaneless diffusers, and how the extent of the blocked region throughout the diffuser varies with both geometry and operating condition. Having analysed the governing performance parameters and flow phenomena, a novel 1-D modelling method is presented and compared to an existing baseline method as well as test data to quantify the improvement in prediction accuracy achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Off-design performance now plays a vital role in the design decisions made for automotive turbocharger turbines. Of particular interest is extracting more energy at high pressure ratios and lower rotational speeds. In this region of operation the U/C value will be low and the rotor will experience high values of positive incidence at the inlet. The positive incidence causes flow to separate on the suction surface and produces high blade loading at inlet, which drives tip leakage. A CFD analysis has been carried out on a number of automotive turbines utilizing non-radial fibred blading. To help improve secondary flows yet meet stress requirements a number of designs have been investigated. The inlet blade angle has been modified in a number of ways. Firstly, the blading has been adjusted as to provide a constant back swept angle in the span wise direction. Using the results of the constant back swept blading studies, the back swept blade angle was then varied in the span wise direction. In addition to this, in an attempt to avoid an increase in stress, the effect of varying the leading edge profile of the blade was investigated. It has been seen that off-design performance is improved by implementing back swept blading at the inlet. Varying the inlet angle in the span wise direction provided more freedom for meeting stress requirements and reduces the negative impact on blade performance at the design point. The blade leading edge profile was seen to offer small improvements during off-design operation with minimal effects on stress within the rotor. However, due to the more pointed nature of the leading edge, the rotor was less tolerant to flow misalignment at the design point.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Guidelines recommend the creation of a wrist radiocephalic arteriovenous fistula (RAVF) as initial hemodialysis vascular access. This study explored the potential of preoperative ultrasound vessel measurements to predict AVF failure to mature (FTM) in a cohort of patients with end-stage renal disease in Northern Ireland

.Methods: A retrospective analysis was performed of all patients who had preoperative ultrasound mapping of upper limb blood vessels carried out from August 2011 to December 2014 and whose AVF reached a functional outcome by March 2015.

Results: There were 152 patients (97% white) who had ultrasound mapping andan AVF functional outcome recorded; 80 (54%) had an upper arm AVF created, and 69 (46%) had a RAVF formed. Logistic regression revealed that female gender (odds ratio [OR], 2.5; 95% confidence interval [CI], 1.12-5.55; P = .025), minimum venous diameter (OR, 0.6; 95% CI, 0.39-0.95; P = .029), and RAVF (OR, 0.4; 95% CI, 0.18-0.89; P = .026) were associated with FTM. On subgroup analysis of the RAVF group, RAVFs with an arterial volume flow <50 mL/min were seven times as likely to fail as RAVFs with higher volume flows (OR, 7.0; 95% CI, 2.35-20.87; P < .001).

Conclusions: In this cohort, a radial artery flow rate <50 mL/min was associated with a sevenfold increased risk of FTM in RAVF, which to our knowledge has not been previously reported in the literature. Preoperative ultrasound mapping adds objective assessment in the clinical prediction of AVF FTM.