92 resultados para Output currents


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This output is a collection of compositions which explore issues of ensemble improvisation, ensemble management and orchestration, real-time and distributed scoring, multi-nodal inputs and outputs, and animated and graphic notation. Compositions include: Activities I; tutti, duet, trio, solo, quartet; Lewitt Notations I; Webwork I; and Sometimes I feel the space between people (voices) in terms of tempos. These compositions are presented in computer animated scores which are synchronized through the network and subject to real-time modification and control. They can be performed by ensembles distributed over large physical spaces connected by the network. The scores for these compositions include software which displays the animations to the performers, software to structure and disseminate score events, and triggering software that allows the control of a performance to be distributed. Scores can also include live electronics which are coordinated with graphic events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To characterize the effects of endothelin (ET)-1 on the Ca2+-activated Cl- conductance of choroidal arteriolar smooth muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the process of lens regeneration in the rat following an extracapsular lens extraction preserving the anterior lens capsule and anterior lens epithelium. We assessed clinically the clarity of the newly regenerated lens, evaluated changes in the lens electrical currents following surgery and during the regeneration process and correlated these changes with findings on light microscopy. Protein analysis of the regenerated lens was also undertaken. Experiments were performed in 41 Sprague-Dawley rats, sacrificed at 0, 2, 4 and 8 weeks postoperatively. Our results showed that complete lens regeneration occurred 8 weeks postoperatively only if the anterior epithelium was preserved and the lens capsule was closed surgically. Lens electrical currents, altered following surgery, recovered in parallel with the process of regeneration of the lens. The newly regenerated lens was optically clear and biochemical analysis revealed a pattern of protein expression resembling that observed during lens development. In conclusion, complete lens regeneration occurs in the rat and it is possible that lens electrical signals, together with other cues, may play an important role in this process. © 2009 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A compact differential 4-way power combiner with 2.3 dB loss and high common-mode rejection characteristic for use in mm-wave PAs is presented. A complete circuit comprised of a power splitter, two-stage cascode PA array, and a power combiner was implemented in SiGe technology. Measured small-signal gain of at least 17 dB was obtained from 74.5 GHz to 80.5 GHz with a peak 21 dB at 79 GHz. The prototype delivered 13.2 dBm P1dB and 14.3 dBm Psat when operated from a single 3.3 V supply at 75 GHz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been argued that the variation in brain activity that occurs when observing another person reflects a representation of actions that is indivisible, and which plays out in full once the intent of the actor can be discerned. We used transcranial magnetic stimulation to probe the excitability of corticospinal projections to 2 intrinsic hand muscles while motions to reach and grasp an object were observed. A symbolic cue either faithfully indicated the required final orientation of the object and thus the nature of the grasp that was required, or was in conflict with the movement subsequently displayed. When the cue was veridical, modulation of excitability was in accordance with the functional role of the muscles in the action observed. If however the cue had indicated that the alternative grasp would be required, modulation of output to first dorsal interosseus was consistent with the action specified, rather than the action observed-until the terminal phase of the motion sequence during which the object was seen lifted. Modulation of corticospinal output during observation is thus segmented-it progresses initially in accordance with the action anticipated, and if discrepancies are revealed by visual input, coincides thereafter with that of the action seen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to evaluate the use of Varian radiotherapy dynamic treatment log (DynaLog) files to verify IMRT plan delivery as part of a routine quality assurance procedure. Delivery accuracy in terms of machine performance was quantified by multileaf collimator (MLC) position errors and fluence delivery accuracy for patients receiving intensity modulated radiation therapy (IMRT) treatment. The relationship between machine performance and plan complexity, quantified by the modulation complexity score (MCS) was also investigated. Actual MLC positions and delivered fraction of monitor units (MU), recorded every 50 ms during IMRT delivery, were extracted from the DynaLog files. The planned MLC positions and fractional MU were taken from the record and verify system MLC control file. Planned and delivered beam data were compared to determine leaf position errors with and without the overshoot effect. Analysis was also performed on planned and actual fluence maps reconstructed from the MLC control file and delivered treatment log files respectively. This analysis was performed for all treatment fractions for 5 prostate, 5 prostate and pelvic node (PPN) and 5 head and neck (H&N) IMRT plans, totalling 82 IMRT fields in ∼5500 DynaLog files. The root mean square (RMS) leaf position errors without the overshoot effect were 0.09, 0.26, 0.19 mm for the prostate, PPN and H&N plans respectively, which increased to 0.30, 0.39 and 0.30 mm when the overshoot effect was considered. Average errors were not affected by the overshoot effect and were 0.05, 0.13 and 0.17 mm for prostate, PPN and H&N plans respectively. The percentage of pixels passing fluence map gamma analysis at 3%/3 mm was 99.94 ± 0.25%, which reduced to 91.62 ± 11.39% at 1%/1 mm criterion. Leaf position errors, but not gamma passing rate, were directly related to plan complexity as determined by the MCS. Site specific confidence intervals for average leaf position errors were set at -0.03-0.12 mm for prostate and -0.02-0.28 mm for more complex PPN and H&N plans. For all treatment sites confidence intervals for RMS errors with the overshoot was set at 0-0.50 mm and for the percentage of pixels passing a gamma analysis at 1%/1 mm a confidence interval of 68.83% was set also for all treatment sites. This work demonstrates the successful implementation of treatment log files to validate IMRT deliveries and how dynamic log files can diagnose delivery errors not possible with phantom based QC. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the construction of linear-in-the-parameters (LITP) models for multi-output regression problems. Most existing stepwise forward algorithms choose the regressor terms one by one, each time maximizing the model error reduction ratio. The drawback is that such procedures cannot guarantee a sparse model, especially under highly noisy learning conditions. The main objective of this paper is to improve the sparsity and generalization capability of a model for multi-output regression problems, while reducing the computational complexity. This is achieved by proposing a novel multi-output two-stage locally regularized model construction (MTLRMC) method using the extreme learning machine (ELM). In this new algorithm, the nonlinear parameters in each term, such as the width of the Gaussian function and the power of a polynomial term, are firstly determined by the ELM. An initial multi-output LITP model is then generated according to the termination criteria in the first stage. The significance of each selected regressor is checked and the insignificant ones are replaced at the second stage. The proposed method can produce an optimized compact model by using the regularized parameters. Further, to reduce the computational complexity, a proper regression context is used to allow fast implementation of the proposed method. Simulation results confirm the effectiveness of the proposed technique. © 2013 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationship between retention loss in single crystal PbTiO3 ferroelectric thin films and leakage currents is demonstrated by piezoresponse and conductive atomic force microscopy measurements. It was found that the polarization reversal in the absence of an electric field followed a stretched exponential behavior 1-exp[-(t/k)(d)] with exponent d>1, which is distinct from a dispersive random walk process with d <. The latter has been observed in polycrystalline films for which retention loss was associated with grain boundaries. The leakage current indicates power law scaling at short length scales, which strongly depends on the applied electric field. Additional information of the microstructure, which contributes to an explanation of the presence of leakage currents, is presented with high resolution transmission electron microscopy analysis.