118 resultados para Operating costs.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article explores the complex and neglected picture of occupational and environmental disease healthcare costs specifically relating to asbestos. Diagnosed mesothelioma cases in Scotland in one calendar year were used to investigate the subject in greater depth. Data from UK sources on asbestos disease types recorded in 2000 and their disease treatment costs were obtained. Acute care economic costs of these diseases are estimated. One hundred and twenty diagnosed, recorded, and treated cases of asbestos-related diseases occurred in 2000 in Scotland. Mesothelioma accounted for 100 cases and directly cost Scottish National Health Service hospitals an estimated 942,038 pounds. The estimated UK figure in 2000 was at least 16,014,646 pounds because official figures for diagnosed and recorded deaths from mesothelioma are running at over 1700 a year with rises predicted for 2010 of 2000 deaths. By 2003, 50,000 people in the UK had died from diagnosed and recorded mesothelioma since records began. Earlier disease treatment costs would have been significantly lower than those in 2000 but, at 2000 prices, cost to the UK was roughly 471,019,000 pounds in acute hospital expenditure. Figures for primary care costs, including caregiver costs, are incomplete or unknown. These disease costs are substantial and have some international generalizability. Treatment patterns and costs vary greatly. Many lung cancer cases due to asbestos exposure occur globally for each mesothelioma case. Hence figures provided in this article are certain to be gross underestimates of the total health service and personal economic costs of asbestos illness and treatment in Scotland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated adult age differences in timing control of fast vs slow repetitive movements using a dual task approach Twenty two young (M = 24 23 yr) and 22 older adults (M = 66 64 yr) performed three cognitive tasks differing in working memory load and response production demands and they tapped series of 550 ms or 2100 ms target Intervals Single task timing was comparable in both groups Dual task timing was characterized by shortening of produced intervals and increases in drift and variability Dual task costs for both cognitive and timing performances were pronounced at slower tapping tempos an effect exacerbated in older adults Our findings implicate attention and working memory processes as critical components of slow movement timing and sources of specific challenges thereof for older adults

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel Class-E power amplifier (PA) topology with transmission-line load network is presented in this brief. When compared with the classic Class-E topology, the new circuit can increase the maximum operating frequency up to 50% higher without trading the other Class-E figures of merit. Neither quarterwave line/massive radio-frequency choke for collector/drain biasing nor additional fundamental-frequency output matching circuit are needed in the proposed PA, thus resulting in a compact design. Closed-form formulations are derived and verified by simulations with practical design limitations carefully taken into consideration and good agreement achieved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reflex discharge plasma, obtained as a hybrid between a Penning discharge plasma (PDP) and a hollow-cathode discharge (HCD) plasma, is analysed as a possible direction-current, high-density plasma source. The experiment is run in oxygen at pressures of 10 mTorr and 1 mTorr, and for discharge currents of 100 to 200 mA. Although the gas pressure is considerably lower than those used in HCDs, the hollow-cathode effect (HCE) occurs for current levels higher than 100 mA and leads to plasma densities comparable with those obtained using inductive plasma sources. The presence of a constant magnetic field leads to the enhancement of electron emission from cathodes under ion bombardment, and to the decreasing of the ion loss by diffusion to the wall.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The plasma parameters and relative positive and negative ion concentrations in a small, filtered, multicusp ion source, operating at low plasma density (