80 resultados para Miniscrew implants
Resumo:
Background: Successful periodontal treatment requires a commitment to regular lifelong maintenance and may be perceived by patients to be costly. This study calculates the total lifetime cost of periodontal treatment in the setting of a specialist periodontal practice and investigates the cost implications of choosing not to proceed with such treatment. Methods: Data from patients treated in a specialist practice in Norway were used to calculate the total lifetime cost of periodontal treatment that included baseline periodontal treatment, regular maintenance, retreatment, and replacing teeth lost during maintenance. Incremental costs for alternative strategies based on opting to forego periodontal treatment or maintenance and to replace any teeth lost with either bridgework or implants were calculated. Results: Patients who completed baseline periodontal treatment but did not have any additional maintenance or retreatment could replace only three teeth with bridgework or two teeth with implants before the cost of replacing additional teeth would exceed the cost of lifetime periodontal treatment. Patients who did not have any periodontal treatment could replace ≤4 teeth with bridgework or implants before a replacement strategy became more expensive. Conclusions: Within the limits of the assumptions made, periodontal treatment in a Norwegian specialist periodontal practice is cost-effective when compared to an approach that relies on opting to replace teeth lost as a result of progressive periodontitis with fixed restorations. In particular, patients who have initial comprehensive periodontal treatment but do not subsequently comply with maintenance could, on average, replace ≤3 teeth with bridgework or two teeth with implants before this approach would exceed the direct cost of lifetime periodontal treatment in the setting of the specialist practice studied. © 2012 American Academy of Periodontology.
Resumo:
Wear and corrosion of metal-on-metal hip replacements results in wear debris and metal-ion release in vivo, which may subsequently cause pain and hypersensitivity for patients. Retrieved metal-on-metal hip replacements have revealed that two-body sliding wear and three-body abrasive wear are the predominant wear mechanisms. However, there is a lack of understanding of the combined effects of wear/corrosion, especially the effect of abrasion-corrosion.
This study investigates the sliding-corrosion and abrasion-corrosion performance of a cast CoCrMo alloy in simulated hip joint environments using a microabrasion rig integrated with an electrochemical cell. Tests have been conducted in 0.9% NaCl, phosphate buffered saline solution, 25% and 50% bovine serum solutions with 0 or 1 g cm(-3) SiC at 37 degrees C. Experimental results reveal that under abrasion-corrosion test conditions, the presence of proteins increased the total specific wear rate. Conversely, electrochemical noise measurements indicated that the average anodic current levels were appreciably lower for the proteinaceous solutions when compared with the inorganic solutions. A severely deformed nanocrystalline layer was identified immediately below the worn surface for both proteinaceous and inorganic solutions. The layer is formed by a recrystallisation process and/or a strain-induced phase transformation that occurs during microabrasion-corrosion. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Previous studies have established that some of the wear damage seen on cast CoCrMo joint surface is caused by entrained third-body hard particles. In this study, wet-cell micro-indentation and nano-scratch tests have been carried out with the direct aim of simulating wear damage induced by single abrasive particles entrained between the surfaces of cast CoCrMo hip implants. In situ electrochemical current noise measurements were uniquely performed to detect and study the wear-induced corrosion as well as the repassivation kinetics under the micro-/nano-scale tribological process. A mathematical model has been explored for the CoCrMo repassivation kinetics after surface oxide film rupture. Greater insights into the nature of the CoCrMo micro-/nano-scale wear-corrosion mechanisms and deformation processes are determined, including the identification of slip band formation, matrix/carbide deformation, nanocrystalline structure formation and strain-induced phase transformation. The electrochemical current noise provides evidence of instantaneous transient corrosion activity at the wearing surface resulting from partial oxide rupturing and stripping, concurrent with the indent/scratch.
Resumo:
Some retrieved CoCrMo hip implants have shown that abrasive wear is one of the possible wear mechanisms invoked within such joints. To date, little work has focused on the third body abrasion of CoCrMo and therefore there is a general lack of understanding of the effect of abrasive size and volume concentration on the tribo-corrosion performance of the CoCrMo alloys. The present work assessed the tribo-corrosion behaviour of cast CoCrMo (F-75) under various abrasion-corrosion conditions by using a modified microabrasion tester incorporating a three-electrode electrochemical cell. The effects of reduced abrasive size/hardness and volume concentration, as well as the role of proteins on the tribo-corrosion performance of the cast CoCrMo alloy were addressed. The correlation between electrochemical and mechanical processes for different abrasion-corrosion test conditions has been discussed in detail. Results show that the reduction in abrasive size and volume concentration can significantly affect the abrasion-corrosion wear mechanisms and the wear-induced corrosion response of the material. The finding of this study implies that the smaller/softer third body particles generated in vivo could also result in significant wear-induced corrosion and therefore potential metal ion release, which could be potentially detrimental to both the patient health and the life span of the implants. © 2009 Elsevier Ltd. All rights reserved.
Resumo:
DESIGN: Randomised controlled trial.
INTERVENTION: Patients aged 65 or above edentate for a minimum of five years, with sufficient bone for two implants in the anterior mandible, were recruited. Those with systemic disease that contraindicated implants or had a low mini-mental state evaluation score were excluded. Patients in both groups had a standard maxillary complete denture fabricated. Patients randomised to the treatment group received a two-implant mandibular overdenture while those in the control group received a standard mandibular complete denture. Three 24-hour dietary recalls were collected by telephone interviews at baseline and at 12 months.
RESULTS: 255 patients were randomised: 128 received a standard complete denture (CD) and 127 a two-implant mandibular overdenture (IOD). 127 patients were available at 12-month follow up, 114 in the CD group and 103 in the IOD group. No significant between-group differences were found.
CONCLUSIONS: Although there is much evidence supporting the adoption of two-implant mandibular overdenture (IOD) treatment as the standard of care for edentate patients, this evidence does not include an improvement in dietary intake at one year for medically healthy independent edentate elders when given no specific dietary counselling.
Resumo:
For older patients, clinicians should consider maintaining teeth and using functionally-orientated treatment strategies as an alternative to removable prostheses. When the remaining dentition has a poor prognosis, key teeth should be preserved as overdenture abutments and a gradual transition to edentulousness planned. Where complete dentures are provided, these can be retained using dental implants to overcome many of the problems associated with conventional replacement dentures.
CLINICAL RELEVANCE: The elderly population of today is better informed and more demanding of oral healthcare providers than previous generations. Clinicians should be aware of all the prosthodontic treatment options available for older patients.
Resumo:
This case report details the successful rehabilitation of an edentulous patient using a complete upper prosthesis and a lower implant retained overdenture. The provision of care was split between a specialist centre and a primary care setting. This approach reduced inconvenience to the patient. Modern surgical and prosthodontic techniques also reduced the total delivery time. After initial consultation a new set of complete dentures was prescribed with changes in design to the originals. The patient was also planned for placement of two mandibular implants to stabilise and retain the mandibular denture. The first line of treatment involved provision of a new set of dentures constructed by the patient's general dental practitioner. Dental implants were then placed in a specialist centre and the patient returned to the dental practice for attachment of the lower denture to the dental implants. The benefits and success of mandibular implant retained dentures are well documented. With delivery of the overdenture, the patient reported increased satisfaction with his prostheses which allowed him to eat a greater range of foods and enabled him to feel confident when speaking and socialising.
Resumo:
Introduction: Chronic atypical neutrophilic dermatosis with lipodystrophy and elevated temperature (CANDLE) is an auto inflammatory syndrome caused by an autosomal recessive gene mutation. This very rare syndrome has been reported in only 14 patients worldwide. A number of clinical signs have been reported including joint contractures, muscle atrophy, microcytic anaemia, and panniculitis-induced childhood lipodystrophy. Further symptoms include recurrent fevers, purpuric skin lesions, periorbital erythema and failure to thrive. This is the first reported case of periodontal manifestations associated with CANDLE syndrome.
Case Presentation: An 11 year old boy was referred to Cork University Dental School and Hospital with evidence of severe periodontal destruction. The patient’s medical condition was managed in Great Ormond Street Children’s Hospital, London. The patient’s dental management included initial treatment to remove teeth of hopeless prognosis followed by prosthodontic rehabilitation using removable partial dentures. This was followed by further non-surgical periodontal treatment and maintenance. In the long term, the potential definitive restorative options, including dental implants, will be evaluated in discussion with the patient’s medical team.
Conclusion: Periodontitis as a manifestation of systemic disease is one of seven categories of periodontitis as defined by the American Academy of Periodontology 1999 classification system. A number of systemic diseases have been associated with advanced periodontal destruction including Diabetes Mellitus, Leukaemia and Papillon-Lefevre Syndrome. In the case described, treatment necessitated a multidisciplinary approach with input from medical and dental specialities for a young patient with severe periodontal destruction associated with CANDLE syndrome.
Resumo:
Punctal plugs (PPs) are miniature medical implants that were initially developed for the treatment of dry eyes. Since their introduction in 1975, many PPs made from different materials and designs have been developed. PPs, albeit generally successful, suffer from drawbacks such as epiphora and suppurative canaliculitis. To overcome these issues intelligent designs of PPs were proposed (e.g. SmartPLUG™ and Form Fit™). PPs are also gaining interest among pharmaceutical scientists for sustaining drug delivery to the eye. This review aims to provide an overview of PPs for dry eye treatment and drug delivery to treat a range of ocular diseases. It also discusses current challenges in using PPs for ocular diseases.
Resumo:
The initial composition of acrylic bone cement along with the mixing and delivery technique used can influence its final properties and therefore its clinical success in vivo. The polymerisation of acrylic bone cement is complex with a number of processes happening simultaneously. Acrylic bone cement mixing and delivery systems have undergone several design changes in their advancement, although the cement constituents themselves have remained unchanged since they were first used. This study was conducted to determine the factors that had the greatest effect on the final properties of acrylic bone cement using a pre-filled bone cement mixing and delivery system. A design of experiments (DoE) approach was used to determine the impact of the factors associated with this mixing and delivery method on the final properties of the cement produced. The DoE illustrated that all factors present within this study had a significant impact on the final properties of the cement. An optimum cement composition was hypothesised and tested. This optimum recipe produced cement with final mechanical and thermal properties within the clinical guidelines and stated by ISO 5833 (International Standard Organisation (ISO), International standard 5833: implants for surgery—acrylic resin cements, 2002), however the low setting times observed would not be clinically viable and could result in complications during the surgical technique. As a result further development would be required to improve the setting time of the cement in order for it to be deemed suitable for use in total joint replacement surgery.
Resumo:
Background Over 20 million people in the US are living with an implantable medical device [ADDIN RW.CITE{{3114 Higgins,DavidM 2009}}1], with similar figures anticipated for Europe. Complications in the use of medical implants include the Foreign Body Response (FBR) characterised by macrophage adherence and fusion, and device-related infection due to bacterial biofilm formationADDIN RW.CITE{{3124 Harding,JacquelineL 2014}}2. Both can have detrimental consequences on the structural and functional integrity of the medical device [ADDIN RW.CITE{{3101 Anderson,JamesM 2008; 3124 Harding,JacquelineL 2014}}2,3], often necessitating removal; a painful and expensive procedure [ADDIN RW.CITE{{3121 Mah,Thien-FahC 2001}}4]. Materials are sought to attenuate both the FBR and device-related infection, leading to medical devices with improved biocompatibility and performance. Objectives The present work involves development of a semi-interpenetrating network (SIPN) hydrogel containing polygalacturonic acid (PGA), a biopolysaccharide similar in structure to hyaluronic acid. We aim to synthesise, characterise and determine the in vitro biocompatibility of the developed SIPN. Results & Discussion We have successfully incorporated PGA into a poly(HEMA) based hydrogel, which shows favourable swelling and wettability. The surface topography appears altered in comparison to the control material, with pronounced micrometer-scale features. In terms of in vitro performance, the SIPN showed increased protein adsorption, and biofilm formation (Staphylococcus epidermidis and Escherichia coli, up to 1 Log CFU/sample greater than control). However the SIPN displayed minimal cytotoxicity towards L929 fibroblasts, and was resistant to the adherence of RAW 264.7 macrophages. Conclusions The PGA incorporated SIPN lacks cytotoxicity and shows reduced macrophage adherence, however the increased biofilm formation highlights a concern regarding possible device related infection in clinical use. Future work will focus on strategies to reduce bacterial adherence, while maintaining biocompatibility.
Resumo:
Objective: Many forms of contraception are available on prescription only for example, the oral contraceptive pill (OCP) and long-acting reversible contraceptives (LARCs). In this analysis we aim to identify key determinants of prescription contraceptive use.
Design: Cross-sectional population survey. Data on sociodemographic indices, concerns about the OCP and perceived barriers to access were collected.
Setting: Data set constructed from a representative population-based telephone survey of community dwelling adults in the Republic of Ireland (RoI)
Participants: 1515 women aged between 18 and 45 years
Main outcome measure: Self-reported user of the OCP or LARCs (intrauterine contraception, contraceptive injections or subdermal contraceptive implants) in the previous 12 months.
Results: For at least some of the previous year, 35% had used the OCP and 14% had used LARCs, while 3% had used two or more of these methods. OCP users were significantly younger, more likely to be unmarried and had higher income than non-users. Overall, 68% agreed with the statement ‘that taking a break from long-term use of the contraceptive pill is a good idea’ and 37% agreed with the statement that ‘the OCP has dangerous side effects’ and this was the strongest predictor variable of non-use of the OCP. Intrauterine contraception users were significantly older, more likely to be married and had lower income than non-users. Injections or subdermal contraceptive implant users were significantly younger, less likely to be married, had lower income and were less likely to agree that taking a break from long-term use of the pill is a good idea than non-users.
Conclusions: Prescription contraceptive use is sociodemographically patterned, with LARCs in particular being associated with lower incomes in the RoI. Concerns about the safety of the OCP remain prevalent and are important and modifiable determinants of contraceptive-related behaviour.
Resumo:
Biodegradable polymers, such as PLA (Polylactide), come from renewable resources like corn starch and if disposed of correctly, degrade and become harmless to the ecosystem making them attractive alternatives to petroleum based polymers. PLA in particular is used in a variety of applications including medical devices, food packaging and waste disposal packaging. However, the industry faces challenges in melt processing of PLA due to its poor thermal stability which is influenced by processing temperatures and shearing.
Identification and control of suitable processing conditions is extremely challenging, usually relying on trial and error, and often sensitive to batch to batch variations. Off-line assessment in a lab environment can result in high scrap rates, long lead times and lengthy and expensive process development. Scrap rates are typically in the region of 25-30% for medical grade PLA costing between €2000-€5000/kg.
Additives are used to enhance material properties such as mechanical properties and may also have a therapeutic role in the case of bioresorbable medical devices, for example the release of calcium from orthopaedic implants such as fixation screws promotes healing. Additives can also reduce the costs involved as less of the polymer resin is required.
This study investigates the scope for monitoring, modelling and optimising processing conditions for twin screw extrusion of PLA and PLA w/calcium carbonate to achieve desired material properties. A DAQ system has been constructed to gather data from a bespoke measurement die comprising melt temperature; pressure drop along the length of the die; and UV-Vis spectral data which is shown to correlate to filler dispersion. Trials were carried out under a range of processing conditions using a Design of Experiments approach and samples were tested for mechanical properties, degradation rate and the release rate of calcium. Relationships between recorded process data and material characterisation results are explored.
Resumo:
OBJECTIVES: Identify the words and phrases that authors used to describe time-to-event outcomes of dental treatments in patients.
MATERIALS AND METHODS: A systematic handsearch of 50 dental journals with the highest Citation Index for 2008 identified articles reporting dental treatment with time-to-event statistics (included "case" articles, n = 95), without time-to-event statistics (active "control" articles, n = 91), and all other articles (passive "control" articles n = 6796). The included and active controls were read, identifying 43 English words across the title, aim and abstract, indicating that outcomes were studied over time. Once identified, these words were sought within the 6796 passive controls. Words were divided into six groups. Differences in use of words were analyzed with Pearson's chi-square across these six groups, and the three locations (title, aim, and abstract).
RESULTS: In the abstracts, included articles used group 1 (statistical technique) and group 2 (statistical terms) more frequently than the active and passive controls (group 1: 35%, 2%, 0.37%, P < 0.001 and group 2: 31%, 1%, 0.06%, P < 0.001). The included and active controls used group 3 (quasi-statistical) equally, but significantly more often than the passive controls (82%, 78%, 3.21%, P < 0.001). In the aims, use of target words was similar for included and active controls, but less frequent for groups 1-4 in the passive controls (P < 0.001). In the title, group 2 (statistical techniques) and groups 3-5 (outcomes) were similar for included and active controls, but groups 2 and 3 were less frequent in the passive controls (P < 0.001). Significantly more included articles used group 6 words (stating the study duration) (54%, 30%, P = 0.001).
CONCLUSION: All included articles used time-to-event analyses, but two-thirds did not include words to highlight this in the abstract. There is great variation in the words authors used to describe dental time-to-event outcomes. Electronic identification of such articles would be inconsistent, with low sensitivity and specificity. Authors should improve the reporting quality. Journals should allow sufficient space in abstracts to summarize research, and not impose unrealistic word limits. Readers should be mindful of these problems when searching for relevant articles. Additional research is required in this field.
Resumo:
Background: Upon completion of Specialty Training in Restorative Dentistry, trainees (StRs) should
be proficient in maxillofacial prosthodontics to meet the restorative needs of head and neck cancer patients (HANC), and in preparation for the Intercollegiate Specialty Fellowship Examination (ISFE).1,2
Objective: The aim of this study is to collate and compare data relating to the training of Restorative Dentistry Rs in the management of HANC patients across different geographical locations within the British Isles. Methods: Current trainees were invited to complete an online questionnaire by the Specialty Registrars in Restorative Dentistry Group (SRRDG). Participants were asked to rate their confidence and experience in assessing and planning treatment for HANC patients, attending theatre and manufacturing surgical obturators, and in providing implants for appropriate cases. Respondents were also asked to appraise clinical and didactic teaching within their unit, and to rate their confidence of passing oncology- based questions in a future ISFE. Results: Responses were obtained from 21 StRs (n=21) training in all five countries within the British Isles. Most respondents were based in England (76%). A third were in their 5th year of training. Less than half reported that they were confident
of independently assessing (48%) or treatment planning (38%) HANC patients. More than half of StRs (52%) indicated that they were not confident of attending theatres alone and manufacturing a surgical obturator. One third (33%) rated their experience of treating oncology patients with implants as poor or very poor, including three in their 5th year of training. Less than one third rated didactic teaching in maxillofacial prosthodontics at their unit as good or excellent. Only 4 respondents indicated that they were confident of answering an ISFE oncology question on management of healthcare delivery. Six StRs expressed concerns over a lack of case-based exposure.
Conclusion: Experience and training in maxillofacial prosthodontics is inconsistent for StRs across the British Isles with many lacking in clinical exposure.