66 resultados para Method of quantification
Resumo:
A novel approach has been developed to determine ranitidine in paediatric samples using dried blood spots (DBS) on Guthrie cards (Whatman 903). A selective and sensitive HPLC-MS/MS assay has been developed and validated using small volumes of blood (30µl). A 6mm disc was punched from each DBS and extracted with methanolic solution of the internal standard (IS) nizatidine. This was further subjected to solid phase extraction (SPE), followed by reversed phase HPLC separation, using a XBridge™ C18 column and mobile phase 10mM ammonium acetate/methanol (98:2 v/v) with a flow rate of 0.3mL/min. This was combined with multiple reaction monitoring (MRM) mass detection using electrospray ionisation (ESI). The calibration curve for ranitidine was found linear over the range 10-500ng/mL (r=0.996). The limit of quantification (LOQ) of the method was validated at 10ng/mL. Accuracy and precision values for within and between days were
Resumo:
Obtaining as much particulate material as possible from questioned items is desirable in forensic science as this allows a range of analyses to be undertaken and the retention of material for others to check. A method of maximising particulate recovery is described using a kidnap case, where minimal staining on clothing (socks) remained as possible indications of where the victim had been held captive. Police intelligence led to a hostage scene that was sampled. Brushing of the socks recovered about 50 sand grains with some silt: ultrasonic agitation and centrifuging recovered over 300 grains of sand, silt and clay. These were visually compared to scene and control samples, allowing exclusion of 52 samples and the retention of one comparison sample as well as other possibles, saving time and money, but maximising sample quantity and quality. © 2011 Elsevier Ireland Ltd.
Resumo:
Aim - To describe a new method of evaluating the topographic distribution of fundus autofluorescence in eyes with retinal disease. Methods - Images of fundus autofluorescence were obtained in five patients and 34 normal volunteers using a confocal scanning laser ophthalmoscope (cSLO). To evaluate the topographic distribution of fundus autofluorescence throughout the posterior pole a rectangular box, 10 x 750 pixels, was used as the area of analysis. The box was placed, horizontally, across the macular region. The intensity of fundus autofluorescence of each pixel within the rectangular box was plotted against its degree of eccentricity. Profiles of fundus autofluorescence from patients were compared with those obtained from the age matched control group and with cSLO images. Results - Profiles of fundus autofluorescence appeared to represent the topographic distribution of fundus autofluorescence throughout the posterior pole appreciated in the cSLO images, and allowed rapid identification and quantification of areas of increased or decreased fundus autofluorescence. Conclusions - Fundus autofluorescence profiles appear to be useful to study the spatial distribution of fundus autofluorescence in eyes with retinal disease.
Resumo:
An in situ method of studying the structure of reactive ionic materials in the solid and liquid states by XAFS is described. These salts have novel catalytic and solvent properties, and the results show that their structure may be studied using transmission XAFS by utilizing pressed disks of BN, graphite, and LiF and is not affected by the sample matrix used.
Resumo:
Bioresorbable polymers such as PLA have an important role to play in the development of temporary implantable medical devices with significant benefits over traditional therapies. However, development of new devices is hindered by high manufacturing costs associated with difficulties in processing the material. A major problem is the lack of insight on material degradation during processing. In this work, a method of quantifying degradation of PLA using IR spectroscopy coupled with computational chemistry and chemometric modeling is examined. It is shown that the method can predict the quantity of degradation products in solid-state samples with reasonably good accuracy, indicating the potential to adapt the method to developing an on-line sensor for monitoring PLA degradation in real-time during processing.
Resumo:
Currently there is no reliable objective method to quantify the setting properties of acrylic bone cements within an operating theatre environment. Ultrasonic technology can be used to determine the acoustic properties of the polymerising bone cement, which are linked to material properties and provide indications of the physical and chemical changes occurring within the cement. The focus of this study was the critical evaluation of pulse-echo ultrasonic test method in determining the setting and mechanical properties of three different acrylic bone cement when prepared under atmospheric and vacuum mixing conditions. Results indicated that the ultrasonic pulse-echo technique provided a highly reproducible and accurate method of monitoring the polymerisation reaction and indicating the principal setting parameters when compared to ISO 5833 standard, irrespective of the acrylic bone cement or mixing method used. However, applying the same test method to predict the final mechanical properties of acrylic bone cement did not prove a wholly accurate approach. Inhomogeneities within the cement microstructure and specimen geometry were found to have a significant influence on mechanical property predictions. Consideration of all the results suggests that the non-invasive and non-destructive pulse-echo ultrasonic test method is an effective and reliable method for following the full polymerisation reaction of acrylic bone cement in real-time and then determining the setting properties within a surgical theatre environment. However the application of similar technology for predicting the final mechanical properties of acrylic bone cement on a consistent basis may prove difficult.