96 resultados para ILL procedures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rationale: Delirium is common in intensive care unit (ICU) patients and is a predictor of worse outcomes and neuroinflammation is a possible mechanism. The antiinflammatory actions of statins may reduce delirium.

Objectives: To determine whether critically ill patients receiving statin therapy had a reduced risk of delirium than those not on statins.

Methods: A prospective cohort analysis of data from consecutive ICU patients admitted to a UK mixed medical and surgical critical care unit between August 2011 and February 2012; the Confusion Assessment Method for ICU was used to determine the days each patient was assessed as being free of delirium during ICU admission.

Measurements and Main Results: Delirium-free days, daily administration of statins, and serum C-reactive protein (CRP) were recorded. Four hundred and seventy consecutive critical care patients were followed, of whom 151 patients received statins. Using randomeffects multivariable logistic regression, statin administration the previous evening was associated with the patient being assessed as free of delirium (odds ratio, 2.28; confidence interval, 1.01-5.13; P , 0.05) and with lower CRP (b = 20.52; P , 0.01) the following day. When the association between statin and being assessed as free of delirium was controlled for CRP, the effect size became nonsignificant (odds ratio, 1.56; confidence interval, 0.64-3.79; P = 0.32).

Conclusions: Ongoing statin therapy is associated with a lower daily risk of delirium in critically ill patients. An ongoing clinical trial, informed by this study, is investigating if statins are a potential therapy for delirium in the critically ill.Copyright © 2014 by the American Thoracic Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pollution of subterranean water by arsenic (As) in Asia has resulted in the worst chemical disaster in human history. For populations living on subsistence rice diets, As contamination of rice grain contributes greatly to dietary As exposure. The main objectives of this study were to compare two dehusking processes: (a) wet process (soaking of rice, boiling and mechanical hulling) and (b) dry process (mechanical hulling), and recommend the method leading to a lower As content in commercial rice. In general, hulling of paddy rice (373 mu g As kg(-1)) significantly decreased As content in rice grain (311 mu g As kg(-1)). The final As concentrations in boiled rice (final product of the wet process) and atab rice (dry process) were 332 and 290 mu g kg(-1). Thus, the dry method is recommended for dehusking paddy rice if not As-free water is available. However, villagers can reduce the As content in the wet system by discarding the soaking water and using new water for the light boiling. Finally, it is not recommended to use rice husk for feeding animals because the As concentration is very high, approximately 1,000 mu g As kg(-1).

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: There are many challenges in delivering rural health services; this is particularly true for the delivery of palliative care. Previous work has identified consistent themes around end-of-life care, including caregiver burden in providing care, the importance of informal care networks and barriers imposed by geography. Despite these well-known barriers, few studies have explored the experience of palliative care in rural settings. The purpose of the present study was to compare the experiences of rural family caregivers actively providing end-of-life care to the experiences of their urban counterparts. Methods: Caregivers' perceived health status, the experience of burden in caregiving, assessment of social supports and the pattern of formal care used by the terminally ill were explored using a consistent and standardized measurement approach. A cross-sectional survey study was conducted with 100 informal caregivers (44 rural, 56 urban) actively providing care to a terminally ill patient recruited from a publicly funded community agency located in northeastern Ontario, Canada. The telephone-based survey included questions assessing: (i) caregiver perceived burden (14-item instrument based on the Caregiver's Burden Scale in End-of-Life Care [CBS-EOLC]); (ii) perceived social support (modified version of the Multidimensional Scale of Perceived Social Support [MSPSS] consisting of 12 items); and (iii) functional status of the care recipient (assessed using the Eastern Collaborative Oncology Group performance scale). Results: Rural and urban caregivers were providing care to recipients with similar functional status; the majority of care recipients were either capable of all self-care or experiencing some limitation in self-care. No group differences were observed for caregiver perceived burden: both rural and urban caregivers reported low levels of burden (CBS-EOLC score of 26.5 [SD=8.1] and 25.0 [SD=9.2], respectively; p=0.41). Urban and rural caregivers also reported similarly high levels of social support (mean MSPSS total score of 4.3 [SD=0.7] and 4.1 [SD=0.8], respectively; p=0.40). Although caregivers across both settings reported using a comparable number of services (rural 4.8 [SD=1.9] vs urban 4.5 [SD=1.8]; p=0.39), the types of services used differed. Rural caregivers reported greater use of family physicians (65.1% vs 40.7%; p=0.02), emergency room visits (31.8% vs 13.0%; p=0.02) and pharmacy services (95.3% vs 70.4%; p=0.002), while urban caregivers reported greater use of caregiver respite services (29.6% vs 11.6%; p=0.03). Conclusion: Through the use of standardized tools, this study explored the experiences of rural informal family caregivers providing palliative care in contrast to the experiences of their urban counterparts. The results of the present study suggest that while there are commonalities to the caregiving experience regardless of setting, key differences also exist. Thus, location is a factor to be considered when implementing palliative care programs and services. © K Brazil, S Kaasalainen, A Williams, C Rodriguez, 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This is an update of a review last published in Issue 5, 2010, of The Cochrane Library. Reducing weaning time is desirable in minimizing potential complications from mechanical ventilation. Standardized weaning protocols are purported to reduce time spent on mechanical ventilation. However, evidence supporting their use in clinical practice is inconsistent. Objectives: The first objective of this review was to compare the total duration of mechanical ventilation of critically ill adults who were weaned using protocols versus usual (non-protocolized) practice.The second objective was to ascertain differences between protocolized and non-protocolized weaning in outcomes measuring weaning duration, harm (adverse events) and resource use (intensive care unit (ICU) and hospital length of stay, cost).The third objective was to explore, using subgroup analyses, variations in outcomes by type of ICU, type of protocol and approach to delivering the protocol (professional-led or computer-driven). Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library Issue 1, 2014), MEDLINE (1950 to January 2014), EMBASE (1988 to January 2014), CINAHL (1937 to January 2014), LILACS (1982 to January 2014), ISI Web of Science and ISI Conference Proceedings (1970 to February 2014), and reference lists of articles. We did not apply language restrictions. The original search was performed in January 2010 and updated in January 2014.Selection criteriaWe included randomized controlled trials (RCTs) and quasi-RCTs of protocolized weaning versus non-protocolized weaning from mechanical ventilation in critically ill adults. Data collection and analysis: Two authors independently assessed trial quality and extracted data. We performed a priori subgroup and sensitivity analyses. We contacted study authors for additional information. Main results: We included 17 trials (with 2434 patients) in this updated review. The original review included 11 trials. The total geometric mean duration of mechanical ventilation in the protocolized weaning group was on average reduced by 26% compared with the usual care group (N = 14 trials, 95% confidence interval (CI) 13% to 37%, P = 0.0002). Reductions were most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. Weaning duration was reduced by 70% (N = 8 trials, 95% CI 27% to 88%, P = 0.009); and ICU length of stay by 11% (N = 9 trials, 95% CI 3% to 19%, P = 0.01). There was significant heterogeneity among studies for total duration of mechanical ventilation (I2 = 67%, P < 0.0001) and weaning duration (I2 = 97%, P < 0.00001), which could not be explained by subgroup analyses based on type of unit or type of approach. Authors' conclusions: There is evidence of reduced duration of mechanical ventilation, weaning duration and ICU length of stay with use of standardized weaning protocols. Reductions are most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. However, significant heterogeneity among studies indicates caution in generalizing results. Some study authors suggest that organizational context may influence outcomes, however these factors were not considered in all included studies and could not be evaluated. Future trials should consider an evaluation of the process of intervention delivery to distinguish between intervention and implementation effects. There is an important need for further development and research in the neurosurgical population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IntroductionAutomated weaning systems may improve adaptation of mechanical support for a patient’s ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. Our objective was to compare mechanical ventilator weaning duration for critically ill adults and children when managed with automated systems versus non-automated strategies. Secondary objectives were to determine differences in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events.MethodsElectronic databases were searched to 30 September 2013 without language restrictions. We also searched conference proceedings; trial registration websites; and article reference lists. Two authors independently extracted data and assessed risk of bias. We combined data using random-effects modelling.ResultsWe identified 21 eligible trials totalling 1,676 participants. Pooled data from 16 trials indicated that automated systems reduced the geometric mean weaning duration by 30% (95% confidence interval (CI) 13% to 45%), with substantial heterogeneity (I2 = 87%, P <0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not with surgical populations or using other systems. Automated systems reduced ventilation duration with no heterogeneity (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of effect on mortality, hospital LOS, reintubation, self-extubation and non-invasive ventilation following extubation. Automated systems reduced prolonged mechanical ventilation and tracheostomy. Overall quality of evidence was high.ConclusionsAutomated systems may reduce weaning and ventilation duration and ICU stay. Due to substantial trial heterogeneity an adequately powered, high quality, multi-centre randomized controlled trial is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.