71 resultados para HF calculations


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electron-impact excitation data for He-like ions are of significant importance for diagnostic applications to both laboratory and astrophysical plasmas. Here we report on the first fully relativistic R -matrix calculations with radiation damping for the He-like ions Fe 24+ and Kr 34+ . Effective collision strengths for these two ions have been determined with and without damping over a wide temperature range for all transitions between the 49 levels through n = 5. We find that damping has a pronounced effect on the effective collision strengths for excitation to some of the low-lying levels, but its effect on excitation to the vast majority of levels is small. At the energy of a resonance peak, we also investigate the effect of radiation damping on the angular distribution of scattered electrons. Finally, we compare our results for Fe 24+ with an earlier intermediate coupling frame transformation R -matrix calculation with radiation damping by Whiteford et al ( J. Phys. B: At. Mol. Opt. Phys. 34 3179) and find good agreement, especially for excitation to the lower levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For applications to laboratory and astrophysical plasmas, there is a great need for accurate electron-impact excitation data between individual levels in the lower charge-state ions of iron. Recently, we have reported on the first intermediate-coupling R -matrix calculation of electron-impact excitation in Fe 4+ , in which the close-coupling expansion of the target included levels from both ground and excited configurations (Ballance et al 2007 J. Phys. B: At. Mol. Opt. Phys. [/0953-4075/40/23/f01] 40 F327 , 2008 Europhys. News 39 14). In this paper, we present the results of two large intermediate-coupling Dirac R -matrix calculations of electron-impact excitation of Fe 5+ . The results from the two calculations, which differ only in the configuration–interaction expansions of the target, are compared. These comparisons provide some indication of the accuracy of the calculations and the resulting data should be useful in modelling plasmas containing iron.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modeling the spectral emission of low-charge iron group ions enables the diagnostic determination of the local physical conditions of many cool plasma environments such as those found in H II regions, planetary nebulae, active galactic nuclei etc. Electron-impact excitation drives the population of the emitting levels and, hence, their emissivities. By carrying-out Breit-Pauli and intermediate coupling frame transformation (ICFT) R-matrix calculations for the electron-impact excitation of Fe$^{2+}$ which both use the exact same atomic structure and the same close-coupling expansion, we demonstrate the validity of the application of the powerful ICFT method to low-charge iron group ions. This is in contradiction to the finding of Bautista et al. [Ap.J.Lett, 718, L189, (2010)] who carried-out ICFT and Dirac R-matrix calculations for the same ion. We discuss possible reasons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photoionization cross section calculations on the halogen-like ions; Kr + and Xe + have been performed for a photon energy range from each ion threshold to 15 eV, using large-scale close-coupling calculations within the Dirac--Coulomb R -matrix approximation. The results from our theoretical work are compared with recent measurements made at the ASTRID merged-beam set-up at the University of Aarhus in Denmark and from the Fourier transform ion cyclotron resonance trap method at the SOLEIL synchrotron radiation facility in Saint-Aubin, France Bizau et al (2011 J. Phys. B: At. Mol. Opt. Phys. 44 055205) and the advanced light source M{ü}ller (2012 private communication), Aguliar et al (2012 J. Phys.: Conf. Ser . at press). For each of these complex ions our theoretical cross section results over the photon energy range investigated are seen to be in excellent agreement with experiment. Resonance energy positions and quantum defects of the prominent Rydberg resonances series identified in the spectra are compared with experiment for these complex halogen-like ions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Petaflop architectures are currently being utilized efficiently to perform large scale computations in Atomic, Molecular and Optical Collisions. We solve the Schr\"odinger or Dirac equation for the appropriate collision problem using the R-matrix or R-matrix with pseudo-states approach. We briefly outline the parallel methodology used and implemented for the current suite of Breit-Pauli and DARC codes. In this report, various examples are shown from our theoretical results compared with experimental results obtained from Synchrotron Radiation facilities where the Cray architecture at HLRS is playing an integral part in our computational projects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have employed the Dirac R -matrix method to determine electron-impact excitation cross sections and effective collision strengths in Ne-like Kr 26+ . Both the configuration-interaction expansion of the target and the close-coupling expansion employed in the scattering calculation included 139 levels up through n = 5. Many of the cross sections are found to exhibit very strong resonances, yet the effects of radiation damping on the resonance contributions are relatively small. Using these collisional data along with multi-configuration Dirac–Fock radiative rates, we have performed collisional-radiative modeling calculations to determine line-intensity ratios for various radiative transitions that have been employed for diagnostics of other Ne-like ions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present spectral modeling results for neutral helium. Our underlying atomic data contains radiative transition rates that are generated from atomic structure calculations and electron-impact excitation rates, that are determined from both the standard R-matrix method and the R-matrix with pseudostates RMPS method. In this paper, we focus on transitions of particular importance to diagnostic line ratios. For example, our calculated rate coefficient for the electron-impact transition 1s3s 1S→1s3p 1P, which has a pronounced effect on the 728.1 nm diagnostic spectral line, is found to be in good agreement with previous experimental mea- surements. We also consider transitions from the 1s2 1S ground and 1s2s 3S terms to terms of the n=4 shell. They are found to be affected significantly by coupling of the bound states to the target continuum continuum coupling, which is included in our RMPS calculation, but not in our standard R-matrix calculation. We perform collisional-radiative calculations to determine spectral line intensity ratios for three ratios of particular interest, namely the 504.8 nm/471.3 nm, 492.2 nm/471.3 nm, and 492.2 nm/504.8 nm line ratios. Comparing our results determined from the RMPS excitation rates with those from the standard R-matrix excitation rates, we find that continuum coupling affects the rate coefficients significantly, leading to different values for all three line ratios. We also compare our modeling results with spectral measurements taken recently on the Auburn Helicon plasma device, finding that the ground and metastable populations are not in equilibrium, and that the experimental measurements are more consistent with the 1s2s 3S metastable term populations being short lived in the plasma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Prevention of cardiovascular disease and heart failure (HF) in a cost-effective manner is a public health goal. This work aims to assess the cost-effectiveness of the St Vincent's Screening TO Prevent Heart Failure (STOP-HF) intervention.

METHODS AND RESULTS: This is a substudy of 1054 participants with cardiovascular risk factors [median age 65.8 years, interquartile range (IQR) 57.8:72.4, with 4.3 years, IQR 3.4:5.2, follow-up]. Annual natriuretic peptide-based screening was performed, with collaborative cardiovascular care between specialist physicians and general practitioners provided to patients with BNP levels >50 pg/mL. Analysis of cost per case prevented and cost-effectiveness per quality-adjusted life year (QALY) gained was performed. The primary clinical endpoint of LV dysfunction (LVD) with or without HF was reduced in intervention patients [odds ratio (OR) 0.60; 95% confidence interval (CI) 0.38-0.94; P = 0.026]. There were 157 deaths and/or emergency hospitalizations for major adverse cardiac events (MACE) in the control group vs. 102 in the intervention group (OR 0.68; 95% CI 0.49-0.93; P = 0.01). The cost per case of LVD/HF prevented was €9683 (sensitivity range -€843 to €20 210), whereas the cost per MACE prevented was €3471 (sensitivity range -€302 to €7245). Cardiovascular hospitalization savings offset increased outpatient and primary care costs. The cost per QALY gain was €1104 and the intervention has an 88% probability of being cost-effective at a willingness to pay threshold of €30 000.

CONCLUSION: Among patients with cardiovascular risk factors, natriuretic peptide-based screening and collaborative care reduced LVD, HF, and MACE, and has a high probability of being cost-effective.

TRIAL REGISTRATION: NCT00921960.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IMPORTANCE: Prevention strategies for heart failure are needed.

OBJECTIVE: To determine the efficacy of a screening program using brain-type natriuretic peptide (BNP) and collaborative care in an at-risk population in reducing newly diagnosed heart failure and prevalence of significant left ventricular (LV) systolic and/or diastolic dysfunction.

DESIGN, SETTING, AND PARTICIPANTS: The St Vincent's Screening to Prevent Heart Failure Study, a parallel-group randomized trial involving 1374 participants with cardiovascular risk factors (mean age, 64.8 [SD, 10.2] years) recruited from 39 primary care practices in Ireland between January 2005 and December 2009 and followed up until December 2011 (mean follow-up, 4.2 [SD, 1.2] years).

INTERVENTION: Patients were randomly assigned to receive usual primary care (control condition; n=677) or screening with BNP testing (n=697). Intervention-group participants with BNP levels of 50 pg/mL or higher underwent echocardiography and collaborative care between their primary care physician and specialist cardiovascular service.

MAIN OUTCOMES AND MEASURES: The primary end point was prevalence of asymptomatic LV dysfunction with or without newly diagnosed heart failure. Secondary end points included emergency hospitalization for arrhythmia, transient ischemic attack, stroke, myocardial infarction, peripheral or pulmonary thrombosis/embolus, or heart failure.

RESULTS: A total of 263 patients (41.6%) in the intervention group had at least 1 BNP reading of 50 pg/mL or higher. The intervention group underwent more cardiovascular investigations (control, 496 per 1000 patient-years vs intervention, 850 per 1000 patient-years; incidence rate ratio, 1.71; 95% CI, 1.61-1.83; P<.001) and received more renin-angiotensin-aldosterone system-based therapy at follow-up (control, 49.6%; intervention, 56.5%; P=.01). The primary end point of LV dysfunction with or without heart failure was met in 59 (8.7%) of 677 in the control group and 37 (5.3%) of 697 in the intervention group (odds ratio [OR], 0.55; 95% CI, 0.37-0.82; P = .003). Asymptomatic LV dysfunction was found in 45 (6.6%) of 677 control-group patients and 30 (4.3%) of 697 intervention-group patients (OR, 0.57; 95% CI, 0.37-0.88; P = .01). Heart failure occurred in 14 (2.1%) of 677 control-group patients and 7 (1.0%) of 697 intervention-group patients (OR, 0.48; 95% CI, 0.20-1.20; P = .12). The incidence rates of emergency hospitalization for major cardiovascular events were 40.4 per 1000 patient-years in the control group vs 22.3 per 1000 patient-years in the intervention group (incidence rate ratio, 0.60; 95% CI, 0.45-0.81; P = .002).

CONCLUSION AND RELEVANCE: Among patients at risk of heart failure, BNP-based screening and collaborative care reduced the combined rates of LV systolic dysfunction, diastolic dysfunction, and heart failure.

TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00921960.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Limited data are available concerning the evolution of the left atrial volume index (LAVI) in pre-heart failure (HF) patients. The aim of this study was to investigate clinical characteristics and serological biomarkers in a cohort with risk factors for HF and evidence of serial atrial dilatation.

METHODS AND RESULTS: This was a prospective substudy within the framework of the STOP-HF cohort (NCT00921960) involving 518 patients with risk factors for HF electively undergoing serial clinical, echocardiographic, and natriuretic peptide assessment. Mean follow-up time between assessments was 15 ± 6 months. 'Progressors' (n = 39) were defined as those with serial LAVI change ≥3.5 mL/m(2) (and baseline LAVI between 20 and 34 mL/m(2)). This cut-off was derived from a calculated reference change value above the biological, analytical, and observer variability of serial LAVI measurement. Multivariate analysis identified significant baseline clinical associates of LAVI progression as increased age, beta-blocker usage, and left ventricular mass index (all P < 0.05). Serological biomarkers were measured in a randomly selected subcohort of 30 'Progressors' matched to 30 'Non-progressors'. For 'Progressors', relative changes in matrix metalloproteinase 9 (MMP9), tissue inhibitor of metalloproteinase 1 (TIMP1), and the TIMP1/MMP9 ratio, markers of interstitial remodelling, tracked with changes in LAVI over time (all P < 0.05).

CONCLUSION: Accelerated LAVI increase was found to occur in up to 14% of all pre-HF patients undergoing serial echocardiograms over a relatively short follow-up period. In a randomly selected subcohort of 'Progressors', changes in LAVI were closely linked with alterations in MMP9, TIMP1, and the ratio of these enzymes, a potential aid in highlighting this at-risk group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we explore the validity of employing a modified version of the nonrelativistic structure code civ3 for heavy, highly charged systems, using Na-like tungsten as a simple benchmark. Consequently, we present radiative and subsequent collisional atomic data compared with corresponding results from a fully relativistic structure and collisional model. Our motivation for this line of study is to benchmark civ3 against the relativistic grasp0 structure code. This is an important study as civ3 wave functions in nonrelativistic R-matrix calculations are computationally less expensive than their Dirac counterparts. There are very few existing data for the W LXIV ion in the literature with which we can compare except for an incomplete set of energy levels available from the NIST database. The overall accuracy of the present results is thus determined by the comparison between the civ3 and grasp0 structure codes alongside collisional atomic data computed by the R-matrix Breit-Pauli and Dirac codes. It is found that the electron-impact collision strengths and effective collision strengths computed by these differing methods are in good general agreement for the majority of the transitions considered, across a broad range of electron temperatures.