90 resultados para FULL HYDRATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors describe a reflection amplifier adapted to have both a reflection and a transmission port. The amplifier uses a single silicon bipolar transistor and demonstrates a reflection gain of 13 dB, transmission gain of 10 dB and 3.4 dB noise figure at 5.25 GHz. The added feature of transmission gain in the reflection amplifier permits practical implementation of full duplex microwave radiofrequency indentification (RFID) tag operation. By using a simple subcarrier modulation scheme full duplex RFID operation utilising this amplifier is demonstrated. These results indicate that for 27 dBm (0.5 W) effective isotropic radiated power (EIRP) transmit power it should be possible to obtain approximately 8 m downlink range and 25 m uplink range

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several observational studies have suggested the potential benefit of internal limiting membrane (ILM) peeling to treat idiopathic full-thickness macular hole (FTMH). However, no strong evidence is available on the potential benefit(s) of this surgical manoeuvre and uncertainty remains among vitreoretinal surgeons about the indication for peeling the ILM, whether to use it in all cases or in long-standing and/or larger holes. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study monitors both the short- and long-term hydration characteristics of concrete using discretized conductivity measurements from initial gauging, through setting and hardening, the latter comprising both the curing and post-curing periods. In particular, attention is directed to the near-surface concrete as it is this zone which protects the steel from the external environment and has a major influence on durability, performance and service-life. A wide range of concrete mixes is studied comprising both plain Portland cement concretes and concretes containing fly-ash and ground granulated blast furnace slag. The parameter normalised conductivity was used to identify four distinct stages in the hydration process and highlight the influence of supplementary cementitious materials (SCM) on hydration and hydration kinetics. A relationship has been presented to account for the temporal decrease in conductivity, post 10-days hydration. The testing procedure and methodology presented lend itself to in-situ monitoring of reinforced concrete structures. (c) 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We address the problem of designing distributed algorithms for large scale networks that are robust to Byzantine faults. We consider a message passing, full information model: the adversary is malicious, controls a constant fraction of processors, and can view all messages in a round before sending out its own messages for that round. Furthermore, each bad processor may send an unlimited number of messages. The only constraint on the adversary is that it must choose its corrupt processors at the start, without knowledge of the processors’ private random bits.

A good quorum is a set of O(logn) processors, which contains a majority of good processors. In this paper, we give a synchronous algorithm which uses polylogarithmic time and Õ(vn) bits of communication per processor to bring all processors to agreement on a collection of n good quorums, solving Byzantine agreement as well. The collection is balanced in that no processor is in more than O(logn) quorums. This yields the first solution to Byzantine agreement which is both scalable and load-balanced in the full information model.

The technique which involves going from situation where slightly more than 1/2 fraction of processors are good and and agree on a short string with a constant fraction of random bits to a situation where all good processors agree on n good quorums can be done in a fully asynchronous model as well, providing an approach for extending the Byzantine agreement result to this model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine whether internal limiting membrane (ILM) peeling improves anatomic and functional outcomes of full-thickness macular hole (FTMH) surgery when compared with the no-peeling technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We introduce a method for measuring the full stress tensor in a crystal utilising the properties of individual point defects. By measuring the perturbation to the electronic states of three point defects with C 3 v symmetry in a cubic crystal, sufficient information is obtained to construct all six independent components of the symmetric stress tensor. We demonstrate the method using photoluminescence from nitrogen-vacancy colour centers in diamond. The method breaks the inverse relationship between spatial resolution and sensitivity that is inherent to existing bulk strain measurement techniques, and thus, offers a route to nanoscale strain mapping in diamond and other materials in which individual point defects can be interrogated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: We explored whether readers can understand key messages without having to read the full review, and if there were differences in understanding between various types of summary.
Design: A randomised experiment of review summaries which compared understanding of a key outcome.
Participants: Members of university staff (n = 36).
Setting: Universities on the island of Ireland.
Method: The Cochrane Review chosen examines the health impacts of the use of electric fans during heat waves. Participants were asked their expectation of the effect these would have on mortality. They were then randomly assigned a summary of the review (i.e. abstract, plain language summary, podcast or podcast transcription) and asked to spend a short time reading/listening to the summary. After this they were again asked about the effects of electric fans on mortality and to indicate if they would want to read the full Review.
Main outcome measure: Correct identification of a key review outcome.
Results: Just over half (53%) of the participants identified its key message on mortality after engaging with their summary. The figures were 33% for the abstract group, 50% for both the plain language and transcript groups and 78% for the podcast group.
Conclusions: The differences between the groups were not statistically significant but suggest that the audio summary might improve knowledge transfer compared to written summaries. These findings should be explored further using a larger sample size and with other reviews.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using a small planetary ball mill, liquid-assisted grinding (LAG) of metal salts or oxides (ZnO, CdO, CdCO3, Cu(OAc)(2)center dot H2O, Co(OAc)(2)center dot 4H(2)O, Mn(OAc)(2)center dot 4H(2)O, Ni(OAc)(2)center dot 4H(2)O, FeSO4 center dot 7H(2)O) with two equivalents of isonicotinic acid (HINA) and small amounts of water ( up to 5.6 molar equivalents) gave discrete aquo complexes trans-[M(INA)(2)(OH2)(4)] (M = Zn, Cd, Cu, Fe, Co, Ni, Mn) efficiently within 30 min. For M = Zn, Cd and Cu these complexes readily undergo reversible formal dehydration to the extended network structures [M(INA)(2)] (M = Zn, Cu) or [Cd(INA)(2)(OH2)]center dot DMF by further LAG with non-aqueous liquids such as methanol or DMF. Overall, the mechanochemical dehydrations are more effective than heating or immersion in bulk solvents. The work demonstrates a two-step mechanochemical synthesis of coordination networks via discrete aquo complexes which may be preferable to single step reactions or grinding-annealing procedures in some cases. For example, the two step method was the only way to prepare [Cd(INA)(2)(OH2)]center dot DMF mechanochemically and the porous network Cu(INA)(2) could not be obtained from the aquo complex by heating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Field testing studies are required for tidal turbine device developers to determine the performance of their turbines in tidal flows. Full-scale testing of the SCHOTTEL tidal turbine has been conducted at Queen’s University Belfast’s tidal site at Strangford Lough, NI. The device was mounted on a floating barge. Testing was conducted over 48 days, for 288 h, during flood tides in daylight hours. Several instruments were deployed, resulting in an expansive data set. The performance results from this data set are presented here. The device, rated to 50 kW at 2.75 m/s was tested in flows up to 2.5 m/s, producing up to 19 kW, when time-averaged. The thrust on the turbine reached 17 kN in the maximum flow. The maximum system efficiency of the turbine in these flows reached 35%. The test campaign was very successful and further tests may be conducted at higher flow speeds in a similar tidal environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider a multipair decode-and-forward relay channel, where multiple sources transmit simultaneously their signals to multiple destinations with the help of a full-duplex relay station. We assume that the relay station is equipped with massive arrays, while all sources and destinations have a single antenna. The relay station uses channel estimates obtained from received pilots and zero-forcing (ZF) or maximum-ratio combining/maximum-ratio transmission (MRC/MRT) to process the signals. To reduce significantly the loop interference effect, we propose two techniques: i) using a massive receive antenna array; or ii) using a massive transmit antenna array together with very low transmit power at the relay station. We derive an exact achievable rate in closed-form for MRC/MRT processing and an analytical approximation of the achievable rate for ZF processing. This approximation is very tight, especially for large number of relay station antennas. These closed-form expressions enable us to determine the regions where the full-duplex mode outperforms the half-duplex mode, as well as, to design an optimal power allocation scheme. This optimal power allocation scheme aims to maximize the energy efficiency for a given sum spectral efficiency and under peak power constraints at the relay station and sources. Numerical results verify the effectiveness of the optimal power allocation scheme. Furthermore, we show that, by doubling the number of transmit/receive antennas at the relay station, the transmit power of each source and of the relay station can be reduced by 1.5dB if the pilot power is equal to the signal power, and by 3dB if the pilot power is kept fixed, while maintaining a given quality-of-service.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A string of repulsively interacting particles exhibits a phase transition to a zigzag structure, by reducing the transverse trap potential or the interparticle distance. Based on the emergent symmetry Z2 it has been argued that this instability is a quantum phase transition, which can be mapped to an Ising model in transverse field. An extensive Density Matrix Renormalization Group analysis is performed, resulting in an high-precision evaluation of the critical exponents and of the central charge of the system, confirming that the quantum linear-zigzag transition belongs to the critical Ising model universality class. Quantum corrections to the classical phase diagram are computed, and the range of experimental parameters where quantum effects play a role is provided. These results show that structural instabilities of one-dimensional interacting atomic arrays can simulate quantum critical phenomena typical of ferromagnetic systems.