74 resultados para Energy system
Resumo:
Sustainable development comprises of three dimensions. The three dimensions are the environment, the social and the economic. There have been many indicators used to measure the three dimensions of sustainability. For example air pollution, consumption of natural resources, quality of open space, noise, equity and opportunities and economic benefits from transport and land use. Urban areas constitute the most crucial factor in the sustainability. Urban systems affect and are affected by natural systems beyond their physical boundaries and in general the interdependence between the urban system and the regional and global environment is not reflected in urban decision making. The use of energy in the urban system constitutes the major element in the construction and function of urban areas. Energy impacts across the boundaries of the three dimensions of sustainability. The objective of this research is to apply energy-use-indicators to the urban system as a measure of sustainability. This methodology is applied to a case study in the United Kingdom.
Resumo:
In an age of depleting oil reserves and increasing energy demand, humanity faces a stalemate between environmentalism and politics, where crude oil is traded at record highs yet the spotlight on being ‘green’ and sustainable is stronger than ever. A key theme on today’s political agenda is energy independence from foreign nations, and the United Kingdom is bracing itself for nuclear renaissance which is hoped will feed the rapacious centralised system that the UK is structured upon. But what if this centralised system was dissembled, and in its place stood dozens of cities which grow and monopolise from their own energy? Rather than one dominant network, would a series of autonomous city-based energy systems not offer a mutually profitable alternative? Bio-Port is a utopian vision of a ‘Free Energy City’ set in Liverpool, where the old dockyards, redundant space, and the Mersey Estuary have been transformed into bio-productive algae farms. Bio-Port Free Energy City is a utopian ideal, where energy is superfluous; in fact so abundant that meters are obsolete. The city functions as an energy generator and thrives from its own product with minimal impact upon the planet it inhabits. Algaculture is the fundamental energy source, where a matrix of algae reactors swamp the abandoned dockyards; which themselves have been further expanded and reclaimed from the River Mersey. Each year, the algae farm is capable of producing over 200 million gallons of bio-fuel, which in-turn can produce enough electricity to power almost 2 million homes. The metabolism of Free-Energy City is circular and holistic, where the waste products of one process are simply the inputs of a new one. Livestock farming – once traditionally a high-carbon countryside exercise has become urbanised. Cattle are located alongside the algae matrix, and waste gases emitted by farmyards and livestock are largely sequestered by algal blooms or anaerobically converted to natural gas. Bio-Port Free Energy City mitigates the imbalances between ecology and urbanity, and exemplifies an environment where nature and the human machine can function productively and in harmony with one another. According to James Lovelock, our population has grown in number to the point where our presence is perceptibly disabling the planet, but in order to reverse the effects of our humanist flaws, it is vital that new eco-urban utopias are realised.
Resumo:
Biofuels have had bad press in recent years. There are primarily two distinct issues. The biofuel crops with the best yields (such as sugarcane or oil palm) grow in tropical countries where habitat destruction has occurred in association with the biofuel system. First generation indigenous energy crops commonly used for transport fuel in Europe (such as rapeseed and wheat) have low yields and/or the energy balance of the associated biofuel system is poor. This paper shows that grass is a crop with significant yields and grass biomethane (a gaseous renewable transport biofuel) has a very good energy balance and does not involve habitat destruction, land use change, new farming practices or annual tilling. The gross and net energy production per hectare are almost identical to palm oil biodiesel; the net energy of the grass system is at least 50% better than the next best indigenous European biofuel system investigated. Ten percent of Irish grasslands could fuel over 55% of the Irish private car fleet. © 2009 Elsevier Ltd. All rights reserved.
Resumo:
Many scientific applications are programmed using hybrid programming models that use both message passing and shared memory, due to the increasing prevalence of large-scale systems with multicore, multisocket nodes. Previous work has shown that energy efficiency can be improved using software-controlled execution schemes that consider both the programming model and the power-aware execution capabilities of the system. However, such approaches have focused on identifying optimal resource utilization for one programming model, either shared memory or message passing, in isolation. The potential solution space, thus the challenge, increases substantially when optimizing hybrid models since the possible resource configurations increase exponentially. Nonetheless, with the accelerating adoption of hybrid programming models, we increasingly need improved energy efficiency in hybrid parallel applications on large-scale systems. In this work, we present new software-controlled execution schemes that consider the effects of dynamic concurrency throttling (DCT) and dynamic voltage and frequency scaling (DVFS) in the context of hybrid programming models. Specifically, we present predictive models and novel algorithms based on statistical analysis that anticipate application power and time requirements under different concurrency and frequency configurations. We apply our models and methods to the NPB MZ benchmarks and selected applications from the ASC Sequoia codes. Overall, we achieve substantial energy savings (8.74 percent on average and up to 13.8 percent) with some performance gain (up to 7.5 percent) or negligible performance loss.
Resumo:
Relevant to laser based electron/ion accelerations, a single shot second harmonic generation frequency resolved optical gating (FROG) system has been developed to characterize laser pulses (80 J, ∼600 fs) incident on and transmitted through nanofoil targets, employing relay imaging, spatial filter, and partially coated glass substrates to reduce spatial nonuniformity and B-integral. The device can be completely aligned without using a pulsed laser source. Variations of incident pulse shape were measured from durations of 613 fs (nearly symmetric shape) to 571 fs (asymmetric shape with pre- or postpulse). The FROG measurements are consistent with independent spectral and autocorrelation measurements. © 2010 American Institute of Physics.
Resumo:
The role of sodium surface species in the modification of a platinum (Pt) catalyst film supported on 8 mol% yttria-stabilised-zirconia (YSZ) was investigated under a flow of 20 kPa oxygen at 400 °C. Cyclic and linear sweep voltammetry were used to investigate the kinetics of the oxygen charge transfer reaction. The Pt/YSZ systems of both ‘clean’ and variable-coverage sodium-modified catalyst surfaces were also characterised using SEM, XPS and work function measurements using the Kelvin probe technique.
Samples with sodium coverage from 0.5 to 100% were used. It was found that sodium addition modifies the binding energy of oxygen onto the catalyst surface. Cyclic voltammetry experiments showed that higher overpotentials were required for oxygen reduction with increasing sodium coverage. In addition, sodium was found to modify oxygen storage and/or adsorption and diffusion increasing current densities at higher cathodic overpotential. Ex situ XPS measurements showed the presence of sodium hydroxide, carbonate and/or oxide species on the catalyst surface, while the Kelvin probe technique showed a decrease of approximately 250 meV in the work function of samples with more than 50% sodium coverage (compared to a nominally ‘clean’ sample).
Resumo:
The manner in which ultrathin films of alumina, deposited at the dielectric-electrode interface, affect the recoverable energy density associated with (BiFeO3)0.6–(SrTiO3)0.4 (BFST) thin film capacitors has been characterised. Approximately 6 nm of alumina on 400 nm of BFST increases the maximum recoverable energy of the system by around 30% from 13 Jcc1 to 17 Jcc1.
Essentially, the alumina acts in the same way as a naturally present parasitic “dead-layer,” distorting the polarisation-field response such that the ultimate polarisation associated with the BFST is pushed to higher values of electric field. The work acts as a proof-of-principle to illustrate how the design of artificial interfacial dielectric “dead-layers” can increase energy densities in simple dielectric capacitors, allowing them to compete more generally with other energy storage technologies.
Resumo:
Multiuser diversity (MUDiv) is one of the central concepts in multiuser (MU) systems. In particular, MUDiv allows for scheduling among users in order to eliminate the negative effects of unfavorable channel fading conditions of some users on the system performance. Scheduling, however, consumes energy (e.g., for making users' channel state information available to the scheduler). This extra usage of energy, which could potentially be used for data transmission, can be very wasteful, especially if the number of users is large. In this paper, we answer the question of how much MUDiv is required for energy limited MU systems. Focusing on uplink MU wireless systems, we develop MU scheduling algorithms which aim at maximizing the MUDiv gain. Toward this end, we introduce a new realistic energy model which accounts for scheduling energy and describes the distribution of the total energy between scheduling and data transmission stages. Using the fact that such energy distribution can be controlled by varying the number of active users, we optimize this number by either i) minimizing the overall system bit error rate (BER) for a fixed total energy of all users in the system or ii) minimizing the total energy of all users for fixed BER requirements. We find that for a fixed number of available users, the achievable MUDiv gain can be improved by activating only a subset of users. Using asymptotic analysis and numerical simulations, we show that our approach benefits from MUDiv gains higher than that achievable by generic greedy access algorithm, which is the optimal scheduling method for energy unlimited systems. © 2010 IEEE.
Resumo:
The planning system has been put forward as a key element in facilitating the low carbon transition (Bulkeley 2006, While 2008), by reducing carbon footprints through initiatives such as encouraging less-energy intensive development, reducing the need to travel or promoting sustainable forms of transport. It has also played a key role on encouraging a shift to more renewable sources of energy, through establishing the spatial ‘rules’ for its regulation, consenting of specific projects and acting as the key arena for mediating a range of social concerns over the resulting socio-technical shift. Despite having this key facilitative role, planning is also regularly seen as a key impediment to renewables, particularly on-shore wind (Ellis et al 2009). There is however, little known about what makes the ‘best’ approach to planning for renewables and indeed little discussion on how to judge the effectiveness of a planning regime for this issue – is it one that maximises generating capacity, protects or landscapes or biodiversity, or perhaps one that maximises social acceptance of renewable developments?
The UK offers a useful context for exploring these issues, with its four main territories (England, Northern Ireland, Scotland and Wales) having broadly similar institutional arrangements, but autonomy over spatial planning during the period in which renewables expanded across the landscape. Each of these jurisdictions has sought to use their planning system to encourage renewables with subtlety different discourses, regulations and spatial strategies. Such an ‘experiment’ offers some important insight into what ‘works’.
This paper will draw on a two year study funded by the UK’s Economic and Social Research Council (RES-062-23-2526), which has charted the effects of devolved administrations on policy and delivery of renewable energy from 1990 to 2012. Drawing on more than 80 interviews, documentary analysis and secondary data sources it describes the growth of renewable capacity in each jurisdiction, explores the spatial strategies adopted and analyses the way in which the broader institutional frameworks in which planning for renewables has emerged. The paper uses this analysis to consider the lessons that can be drawn from the comparable experience of the devolved administrations in the UK and points to the ways in which we should evaluate the effectiveness of planning regimes for renewable energy.
Resumo:
Practical demonstration of the operational advantages gained through the use of a co-operating retrodirective array (RDA) basestation and Van Atta node arrangements is discussed. The system exploits a number of inherent RDA features to provide analogue real time multifunctional operation at low physical complexity. An active dual-conversion four element RDA is used as the power distribution source (basestation) while simultaneously achieving a receive sensitivity level of ??109 dBm and 3 dB automatic beam steering angle of ??45??. When mobile units are each equipped with a semi-passive four element Van Atta array, it is shown mobile device orientation issues are mitigated and optimal energy transfer can occur because of automatic beam formation resulting from retrodirective self-pointing action. We show that operation in multipath rich environments with or without line of sight acts to reduce average power density limits in the operating volume with high energy density occurring at mobile nodes sites only. The system described can be used as a full duplex ASK communications link, or, as a means for remote node charging by wireless means, thereby enhancing deployment opportunities between unstabilised moving platforms.
Voltage Sensing Using an Asynchronous Charge-to-Digital Converter for Energy-Autonomous Environments
Resumo:
In future systems with relatively unreliable and unpredictable energy sources such as harvesters, the system power supply may become non-deterministic. For energy effective operations, Vdd is an important parameter in any meaningful system control mechanism. Reliable and accurate on-chip voltage sensors are therefore indispensible for the power and computation management of such systems. Existing voltage sensing methods are not suitable because they usually require a stable and known reference (voltage, current, time, frequency, etc.), which is difficult to obtain in this environment. This paper describes an autonomous reference-free voltage sensor designed using an asynchronous counter powered by the charge on a capacitor and a small controller. Unlike existing methods, the voltage information is directly generated as a digital code. The sensor, fabricated in the 180 nm technology node, was tested successfully through performing measurements over the voltage range from 1.8 V down to 0.8 V.
Resumo:
This paper investigates the use of plug-in parking lots (SmartPark) as integral energy storage to improve small-signal stability using plug-in electric vehicles (PEV). The paper establishes the Phillips-Heffron model of a power system for a SmartPark solution. Based on this model, SmartPark-based stabilisers have been designed based using phase compensation to improve power system oscillation stability. The effectiveness of stabilisation superimposed on the active and reactive power regulators is verified by simulations obtained from a multi-machine power system model with SmartPark and a large-scale wind farm inclusion.
Resumo:
Increased complexity and interconnectivity of Supervisory Control and Data Acquisition (SCADA) systems in Smart Grids potentially means greater susceptibility to malicious attackers. SCADA systems with legacy communication infrastructure have inherent cyber-security vulnerabilities as these systems were originally designed with little consideration of cyber threats. In order to improve cyber-security of SCADA networks, this paper presents a rule-based Intrusion Detection System (IDS) using a Deep Packet Inspection (DPI) method, which includes signature-based and model-based approaches tailored for SCADA systems. The proposed signature-based rules can accurately detect several known suspicious or malicious attacks. In addition, model-based detection is proposed as a complementary method to detect unknown attacks. Finally, proposed intrusion detection approaches for SCADA networks are implemented and verified via Snort rules.