64 resultados para Cost-effective methods
Resumo:
OBJECTIVE: To assess the efficiency of alternative monitoring services for people with ocular hypertension (OHT), a glaucoma risk factor.
DESIGN: Discrete event simulation model comparing five alternative care pathways: treatment at OHT diagnosis with minimal monitoring; biennial monitoring (primary and secondary care) with treatment if baseline predicted 5-year glaucoma risk is ≥6%; monitoring and treatment aligned to National Institute for Health and Care Excellence (NICE) glaucoma guidance (conservative and intensive).
SETTING: UK health services perspective.
PARTICIPANTS: Simulated cohort of 10 000 adults with OHT (mean intraocular pressure (IOP) 24.9 mm Hg (SD 2.4).
MAIN OUTCOME MEASURES: Costs, glaucoma detected, quality-adjusted life years (QALYs).
RESULTS: Treating at diagnosis was the least costly and least effective in avoiding glaucoma and progression. Intensive monitoring following NICE guidance was the most costly and effective. However, considering a wider cost-utility perspective, biennial monitoring was less costly and provided more QALYs than NICE pathways, but was unlikely to be cost-effective compared with treating at diagnosis (£86 717 per additional QALY gained). The findings were robust to risk thresholds for initiating monitoring but were sensitive to treatment threshold, National Health Service costs and treatment adherence.
CONCLUSIONS: For confirmed OHT, glaucoma monitoring more frequently than every 2 years is unlikely to be efficient. Primary treatment and minimal monitoring (assessing treatment responsiveness (IOP)) could be considered; however, further data to refine glaucoma risk prediction models and value patient preferences for treatment are needed. Consideration to innovative and affordable service redesign focused on treatment responsiveness rather than more glaucoma testing is recommended.
Resumo:
Background
Primary angle-closure glaucoma is a leading cause of irreversible blindness worldwide. In early-stage disease, intraocular pressure is raised without visual loss. Because the crystalline lens has a major mechanistic role, lens extraction might be a useful initial treatment.
Methods
From Jan 8, 2009, to Dec 28, 2011, we enrolled patients from 30 hospital eye services in five countries. Randomisation was done by a web-based application. Patients were assigned to undergo clear-lens extraction or receive standard care with laser peripheral iridotomy and topical medical treatment. Eligible patients were aged 50 years or older, did not have cataracts, and had newly diagnosed primary angle closure with intraocular pressure 30 mm Hg or greater or primary angle-closure glaucoma. The co-primary endpoints were patient-reported health status, intraocular pressure, and incremental cost-effectiveness ratio per quality-adjusted life-year gained 36 months after treatment. Analysis was by intention to treat. This study is registered, number ISRCTN44464607.
Findings
Of 419 participants enrolled, 155 had primary angle closure and 263 primary angle-closure glaucoma. 208 were assigned to clear-lens extraction and 211 to standard care, of whom 351 (84%) had complete data on health status and 366 (87%) on intraocular pressure. The mean health status score (0·87 [SD 0·12]), assessed with the European Quality of Life-5 Dimensions questionnaire, was 0·052 higher (95% CI 0·015–0·088, p=0·005) and mean intraocular pressure (16·6 [SD 3·5] mm Hg) 1·18 mm Hg lower (95% CI –1·99 to –0·38, p=0·004) after clear-lens extraction than after standard care. The incremental cost-effectiveness ratio was £14 284 for initial lens extraction versus standard care. Irreversible loss of vision occurred in one participant who underwent clear-lens extraction and three who received standard care. No patients had serious adverse events.
Interpretation
Clear-lens extraction showed greater efficacy and was more cost-effective than laser peripheral iridotomy, and should be considered as an option for first-line treatment.
Resumo:
Three-dimensional ordered mesoporous (3DOM) CuCo2O4 materials have been synthesized via a hard template and used as bifunctional electrocatalysts for rechargeable Li-O2 batteries. The characterization of the catalyst by X-ray diffractometry and transmission electron microscopy confirms the formation of a single-phase, 3-dimensional, ordered mesoporous CuCo2O4 structure. The as-prepared CuCo2O4 nanoparticles possess a high specific surface area of 97.1 m2 g- 1 and a spinel crystalline structure. Cyclic voltammetry demonstrates that mesoporous CuCo2O4 catalyst enhances the kinetics for either oxygen reduction reaction (ORR) or oxygen evolution reaction (OER). The Li-O2 battery utilizing 3DOM CuCo2O4 shows a higher specific capacity of 7456 mAh g- 1 than that with pure Ketjen black (KB). Moreover, the CuCo2O4-based electrode enables much enhanced cyclability with a 610 mV smaller discharge-recharge voltage gap than that of the carbon-only cathode at a current rate of 100 mA g- 1. Such excellent catalytic performance of CuCo2O4 could be associated with its larger surface area and 3D ordered mesoporous structure. The excellent electrochemical performances coupled with its facile and cost-effective way will render the 3D mesoporous CuCo2O4 nanostructures as attractive electrode materials for promising application in Li-O2 batteries.
Resumo:
Aflatoxins are a group of carcinogenic compounds produced by Aspergillus fungi that can grow on different agricultural crops. Both acute and chronic exposure to these mycotoxins can cause serious illness. Due to the high occurrence of aflatoxins in crops worldwide fast and cost-effective analytical methods are required for the identification of contaminated agricultural commodities before they are processed into final products and placed on the market. In order to provide new tools for aflatoxin screening two prototype fast ELISA methods: one for the detection of aflatoxin B1 and the other for total aflatoxins were developed. Seven monoclonal antibodies with unique high sensitivity and at the same time good cross-reactivity profiles were produced. The monoclonal antibodies were characterized and two antibodies showing IC50 of 0.037 ng/mL and 0.031 ng/mL for aflatoxin B1 were applied in simple and fast direct competitive ELISA tests. The methods were validated for peanut matrix as this crop is one of the most affected by aflatoxin contamination. The detection capabilities of aflatoxin B1 and total aflatoxins ELISAs were 0.4 μg/kg and 0.3 μg/kg for aflatoxin B1, respectively, which are one of the lowest reported values. Total aflatoxins ELISA was also validated for the detection of aflatoxins B2, G1 and G2. The application of the developed tests was demonstrated by screening 32 peanut samples collected from the UK retailers. Total aflatoxins ELISA was further applied to analyse naturally contaminated maize porridge and distiller's dried grain with solubles samples and the results were correlated with these obtained by UHPLC-MS/MS method.