74 resultados para Compact


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel design for a compact gamma-ray spectrometer is presented. The proposed system allows for spectroscopy of high-flux multi-MeV gamma-ray beams with MeV energy resolution in a compact design. In its basic configuration, the spectrometer exploits conversion of gamma-rays into electrons via Compton scattering in a low-Z material. The scattered electron population is then spectrally resolved using a magnetic spectrometer. The detector is shown to be effective for gamma-ray energies between 3 and 20 MeV. The main properties of the spectrometer are confirmed by Monte Carlo simulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low-profile wearable antenna suitable for integration into low-cost, disposable medical vital signs monitors is presented. Simulated and measured antenna performance was characterized on a layered human tissue phantom, representative of the thorax region of a range of human bodies. The wearable antenna has sufficient bandwidth for the 868 MHz Industrial, Scientific and Medical frequency band. Wearable radiation efficiency of up to 30 % is reported when mounted in close proximity to the novel human tissue phantom antenna test-bed at 868 MHz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter presents the design of a thin microwave absorber which exhibits a -10 dB reflectivity bandwidth of 108% at normal incidence and 16% for simultaneous suppression of TE and TM polarised waves over the angular range 0-45° is presented. The structure consists of a 3 mm-thick metal backed frequency selective surface (FSS) with four resistively loaded hexagonal loop elements in each unit cell. The surface resistivity and width of the loops are carefully chosen to maximise the bandwidth by merging the reflection nulls that are generated by the multi-resonant absorber. Measurement and simulation results are in good agreement over the broad frequency range 7.8-24 GHz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of TiO 2 photocatalysis for the destruction of dyes such as methylene blue has been extensively reported. One of the challenges faced in both the laboratory and large scale water treatment plants is the fact that the samples have to be removed from the reactor vessel and the catalyst separated prior to analysis being undertaken. In this paper we report the development of a simple fluorimeter instrument and its use in monitoring the photocatalytic destruction of methylene blue dyes in the presence of catalyst suspensions. The results reported show that the instrument provides an effective method for in situ monitoring of the photocatalytic destruction of fluorescent dyes hence allowing more accurate measurement due to the minimisation of sample loss and cross contamination. Furthermore it also provides a method for real time monitoring of the dye pollutant destruction in large scale photocatalytic reactors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultra-intense lasers can nowadays routinely accelerate kiloampere ion beams. These unique sources of particle beams could impact many societal (e.g., proton-therapy or fuel recycling) and fundamental (e.g., neutron probing) domains. However, this requires overcoming the beam angular divergence at the source. This has been attempted, either with large-scale conventional setups or with compact plasma techniques that however have the restriction of short (<1 mm) focusing distances or a chromatic behavior. Here, we show that exploiting laser-triggered, long-lasting (>50 ps), thermoelectric multi-megagauss surface magnetic (B)-fields, compact capturing, and focusing of a diverging laser-driven multi-MeV ion beam can be achieved over a wide range of ion energies in the limit of a 5° acceptance angle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many AMS systems can measure 14C, 13C and 12C simultaneously thus providing δ13C values which can be used for fractionation normalization without the need for offline 13C /12C measurements on isotope ratio mass spectrometers (IRMS). However AMS δ13C values on our 0.5MV NEC Compact Accelerator often differ from IRMS values on the same material by 4-5‰ or more. It has been postulated that the AMS δ13C values account for the potential graphitization and machine induced fractionation, in addition to natural fractionation, but how much does this affect the 14C ages or F14C? We present an analysis of F14C as a linear least squares fit with AMS δ13C results for several of our secondary standards. While there are samples for which there is an obvious correlation between AMS δ13C and F14C, as quantified with the calculated probability of no correlation, we find that the trend lies within one standard deviation of the variance on our F14C measurements. Our laboratory produces both zinc and hydrogen reduced graphite, and we present our results for each type. Additionally, we show the variance on our AMS δ13C measurements of our secondary standards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We initiate the study of sets of p-multiplicity in locally compact groups and their operator versions. We show that a closed subset E of a second countable locally compact group G is a set of p-multiplicity if and only if E∗={(s,t):ts−1∈E} is a set of operator p-multiplicity. We exhibit examples of sets of p-multiplicity, establish preservation properties for unions and direct products, and prove a p-version of the Stone–von Neumann Theorem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physically Unclonable Functions (PUFs), exploit inherent manufacturing variations and present a promising solution for hardware security. They can be used for key storage, authentication and ID generations. Low power cryptographic design is also very important for security applications. However, research to date on digital PUF designs, such as Arbiter PUFs and RO PUFs, is not very efficient. These PUF designs are difficult to implement on Field Programmable Gate Arrays (FPGAs) or consume many FPGA hardware resources. In previous work, a new and efficient PUF identification generator was presented for FPGA. The PUF identification generator is designed to fit in a single slice per response bit by using a 1-bit PUF identification generator cell formed as a hard-macro. In this work, we propose an ultra-compact PUF identification generator design. It is implemented on ten low-cost Xilinx Spartan-6 FPGA LX9 microboards. The resource utilization is only 2.23%, which, to the best of the authors' knowledge, is the most compact and robust FPGA-based PUF identification generator design reported to date. This PUF identification generator delivers a stable range of uniqueness of around 50% and good reliability between 85% and 100%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On 2011 May 31 UT a supernova (SN) exploded in the nearby galaxy M51 (the Whirlpool Galaxy). We discovered this event using small telescopes equipped with CCD cameras and also detected it with the Palomar Transient Factory survey, rapidly confirming it to be a Type II SN. Here, we present multi-color ultraviolet through infrared photometry which is used to calculate the bolometric luminosity and a series of spectra. Our early-time observations indicate that SN 2011dh resulted from the explosion of a relatively compact progenitor star. Rapid shock-breakout cooling leads to relatively low temperatures in early-time spectra, compared to explosions of red supergiant stars, as well as a rapid early light curve decline. Optical spectra of SN 2011dh are dominated by H lines out to day 10 after explosion, after which He I lines develop. This SN is likely a member of the cIIb (compact IIb) class, with progenitor radius larger than that of SN 2008ax and smaller than the eIIb (extended IIb) SN 1993J progenitor. Our data imply that the object identified in pre-explosion Hubble Space Telescope images at the SN location is possibly a companion to the progenitor or a blended source, and not the progenitor star itself, as its radius (~1013 cm) would be highly inconsistent with constraints from our post-explosion spectra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses compact-stencil finite difference time domain (FDTD) schemes for approximating the 2D wave equation in the context of digital audio. Stability, accuracy, and efficiency are investigated and new ways of viewing and interpreting the results are discussed. It is shown that if a tight accuracy constraint is applied, implicit schemes outperform explicit schemes. The paper also discusses the relevance to digital waveguide mesh modelling, and highlights the optimally efficient explicit scheme.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Existing compact routing schemes, e.g., Thorup and Zwick [SPAA 2001] and Chechik [PODC 2013], often have no means to tolerate failures, once the system has been setup and started. This paper presents, to our knowledge, the first self-healing compact routing scheme. Besides, our schemes are developed for low memory nodes, i.e., nodes need only O(log2 n) memory, and are thus, compact schemes.
We introduce two algorithms of independent interest: The first is CompactFT, a novel compact version (using only O(log n) local memory) of the self-healing algorithm Forgiving Tree of Hayes et al. [PODC 2008]. The second algorithm (CompactFTZ) combines CompactFT with Thorup-Zwick’s treebased compact routing scheme [SPAA 2001] to produce a fully compact self-healing routing scheme. In the self-healing model, the adversary deletes nodes one at a time with the affected nodes self-healing locally by adding few edges. CompactFT recovers from each attack in only O(1) time and ∆ messages, with only +3 degree increase and O(log∆) graph diameter increase, over any sequence of deletions (∆ is the initial maximum degree).
Additionally, CompactFTZ guarantees delivery of a packet sent from sender s as long as the receiver has not been deleted, with only an additional O(y log ∆) latency, where y is the number of nodes that have been deleted on the path between s and t. If t has been deleted, s gets informed and the packet removed from the network.