77 resultados para BUCKLING


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pseudophakic retinal detachment is a rare, but potentially serious, complication of cataract surgery. The incidence of pseudophakic retinal detachment following current surgical techniques of cataract extraction, including extracapsular cataract extraction by nuclear expression and phacoemulsification, is lower than that found after intracapsular cataract extraction. The risk of pseudophakic retinal detachment appears to be increased in myopic patients, in those patients in whom vitreous loss had occurred at the time of cataract surgery, and in patients undergoing Nd:YAG posterior capsulotomy. Most cases present to the clinician when the macula is already detached and the central vision is affected. When evaluating patients with pseudophakic retinal detachment, the fundal view is often impaired by anterior or posterior capsular opacification, reflections related to the intraocular lens, or poor mydriasis. Scleral buckling, pneumatic retinopexy, and primary pars plana vitrectomy, with or without combined scleral buckling, are the surgical techniques used to treat pseudophakic retinal detachment. Anatomical success rates are high after vitreo-retinal surgery for pseudophakic retinal detachment, although a smaller proportion of patients recover good vision following surgery. © 2003 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: A giant retinal tear is a full-thickness retinal break that extends circumferentially around the retina for 90 degrees or more in the presence of a posteriorly detached vitreous. It causes significant visual morbidity from retinal detachment and proliferative vitreoretinopathy. The fellow eye of patients who have had a spontaneous giant retinal tear has an increased risk of developing a giant retinal tear, a retinal detachment or both. Interventions such as 360-degree encircling scleral buckling, 360-degree cryotherapy and 360-degree laser photocoagulation have been advocated by some ophthalmologists as prophylaxis for the fellow eye against the development of a giant retinal tear and/or a retinal detachment, or to prevent its extension. OBJECTIVES: To evaluate the effectiveness of prophylactic 360-degree interventions in the fellow eye of patients with unilateral giant retinal tear to prevent the occurrence of a giant retinal tear and/or a retinal detachment. SEARCH STRATEGY: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2008, Issue 4), MEDLINE (January 1950 to December 2008), EMBASE (January 1980 to December 2008) and Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to December 2008). In addition, we searched the proceedings of the Annual Meeting of the Association for Research in Vision and Ophthalmology (ARVO) up to 2008 for information about other relevant studies. There were no language or date restrictions in the search for trials. The electronic databases were last searched on 15 December 2008. SELECTION CRITERIA: Prospective randomised controlled trials (RCTs) comparing one prophylactic treatment for fellow eyes of patients with giant retinal tear against observation (no treatment) or another form of prophylactic treatment. In the absence of RCTs, we planned to discuss case-control studies that met the inclusion criteria but we would not conduct a meta-analysis using these studies. DATA COLLECTION AND ANALYSIS: We did not find any studies that met the inclusion criteria for the review and therefore no assessment of methodological quality or meta-analysis could be performed. MAIN RESULTS: No studies met the inclusion criteria for this review. AUTHORS' CONCLUSIONS: No strong evidence in the literature was found to support or refute prophylactic 360-degree treatments to prevent a giant retinal tear or a retinal detachment in the fellow eye of patients with unilateral giant retinal tears.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A giant retinal tear is a full-thickness retinal break that extends circumferentially around the retina for 90 degrees or more in the presence of a posteriorly detached vitreous. It causes significant visual morbidity from retinal detachment and proliferative vitreoretinopathy. The fellow eye of patients who have had a spontaneous giant retinal tear has an increased risk of developing a giant retinal tear, a retinal detachment or both. Interventions such as 360-degree encircling scleral buckling, 360-degree cryotherapy and 360-degree laser photocoagulation have been advocated by some ophthalmologists as prophylaxis for the fellow eye against the development of a giant retinal tear and/or a retinal detachment, or to prevent its extension. To evaluate the effectiveness of prophylactic 360-degree interventions in the fellow eye of patients with unilateral giant retinal tear to prevent the occurrence of a giant retinal tear, a retinal detachment or both. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 11), MEDLINE (January 1950 to December 2011), EMBASE (January 1980 to December 2011), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to December 2011), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 6 December 2011. In addition, we searched the proceedings of the Annual Meeting of the Association for Research in Vision and Ophthalmology (ARVO) up to 2008 for information about other relevant studies. Prospective randomised controlled trials (RCTs) comparing one prophylactic treatment for fellow eyes of patients with giant retinal tear against observation (no treatment) or another form of prophylactic treatment. In the absence of RCTs, we planned to discuss case-control studies that met the inclusion criteria but we would not conduct a meta-analysis using these studies. We did not find any studies that met the inclusion criteria for the review and therefore no assessment of methodological quality or meta-analysis could be performed. No studies met the inclusion criteria for this review. No strong evidence in the literature was found to support or refute prophylactic 360-degree treatments to prevent a giant retinal tear or a retinal detachment in the fellow eye of patients with unilateral giant retinal tears.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A giant retinal tear (GRT) is a full-thickness neurosensory retinal break that extends circumferentially around the retina for three or more clock hours in the presence of a posteriorly detached vitreous. Its incidence in large population-based studies has been estimated as 1.5% of rhegmatogenous retinal detachments, with a significant male preponderance, and bilaterality in 12.8%. Most GRTs are idiopathic, with trauma, hereditary vitreoretinopathies and high myopia each being causative in decreasing frequency. The vast majority of GRTs are currently managed with a pars plana vitrectomy; the use of adjunctive circumferential scleral buckling is debated, but no studies have shown a clear anatomical or visual advantage with its use. Similarly, silicone oil tamponade does not influence long-term outcomes when compared with gas. Primary and final retinal reattachment rates are achieved in 88% and 95% of patients, respectively. Even when the retina remains attached, however, visual recovery may be limited. Furthermore, fellow eyes of patients with a GRT are at higher risk of developing retinal tears and retinal detachment. Prophylactic treatment under these circumstances may be considered but there is no firm evidence of its efficacy at the present time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An approach for seismic damage identification of a single-storey steel concentrically braced frame (CBF) structure is presented through filtering and double integration of a recorded acceleration signal. A band-pass filter removes noise from the acceleration signal followed by baseline correction being used to reduce the drift in velocity and displacement during numerical integration. The pre-processing achieves reliable numerical integration that predicts the displacement response accurately when compared to the measured lateral in-plane displacement of the CBF structure. The lateral displacement of the CBF structure is used to infer buckling and yielding of bracing members through seismic tests. The level of interstorey drift of the CBF during a seismic excitation allows the yield and buckling of the bracing members to be identified and indirectly detects damage based on exceedance of calculated displacement limits. The calculated buckling and yielding displacement threshold limits used to identify damage are demonstrated to accurately identify initial buckling and yielding in the bracing members.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the results of non-linear elasto-plastic implicit dynamic finite element analyses that are used to predict the collapse behaviour of cold-formed steel portal frames at elevated temperatures. The collapse behaviour of a simple rigid-jointed beam idealisation and a more accurate semi-rigid jointed shell element idealisation are compared for two different fire scenarios. For the case of the shell element idealisation, the semi-rigidity of the cold-formed steel joints is explicitly taken into account through modelling of the bolt-hole elongation stiffness. In addition, the shell element idealisation is able to capture buckling of the cold-formed steel sections in the vicinity of the joints. The shell element idealisation is validated at ambient temperature against the results of full-scale tests reported in the literature. The behaviour at elevated temperatures is then considered for both the semi-rigid jointed shell and rigid-jointed beam idealisations. The inclusion of accurate joint rigidity and geometric non-linearity (second order analysis) are shown to affect the collapse behaviour at elevated temperatures. For each fire scenario considered, the importance of base fixity in preventing an undesirable outwards collapse mechanism is demonstrated. The results demonstrate that joint rigidity and varying fire scenarios should be considered in order to allow for conservative design.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Adsorption of 0.5 monolayer of N adatoms on W{100} results in a sharp (root 2 X root 2)R45 degrees LEED pattern. The only previous quantitative LEED study of this system gave a simple overlayer model with a Pendry R-factor of 0.55. An exhaustive search has been made of possible structures, including a novel vacancy reconstruction, displacive reconstructions and underlayer adsorption. From this work a new overlayer structure is derived with an R(p) value of 0.22, displaying a considerable buckling of 0.27 +/- 0.05 Angstrom within the second W layer and consequently involving large changes in the interlayer spacings of the surface. The N adatom is pseudo-five-fold coordinated to the W surface, bonding to a second-layer W atom with a nearest-neighbour bond length of 2.13 Angstrom and with the four next-nearest-neighbour W atoms in the surface plane at 2.27 Angstrom. The structure does not resolve the work function anomaly observed on this surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Deposition of 0.5 ML of Cu on W(100) leads to the formation of a sharp c(2 x 2) structure when the surface is annealed at 800 K. A LEED intensity analysis reveals that the Cu atoms are adsorbed displacively into W sites, forming an ordered 2D surface alloy. Due to the lattice mismatch between copper and tungsten, a substantial buckling of the first layer of the alloy is also observed. The clean, bulk terminated W(100) surface is only just stable relative to the c(2 x 2) vacancy covered W(100) surface. This relative stability of the vacancy structure explains the driving force behind the formation of this alloy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A high-fidelity composite damage model is presented and applied to predict low-velocity impact damage, compression after impact (CAI) strength and crushing of thin-walled composite structures. The simulated results correlated well with experimental testing in terms of overall force-displacement response, damage morphologies and energy dissipation. The predictive power of this model makes it suitable for use as part of a virtual testing methodology, reducing the reliance on physical testing.  

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper considers the optimal design of fabricated steel beams for long-span portal frames. The design optimisation takes into account ultimate as well as serviceability limit states, adopting deflection limits recommended by the Steel Construction Institute (SCI). Results for three benchmark frames demonstrate the efficiency of the optimisation methodology. A genetic algorithm (GA) was used to optimise the dimensions of the plates used for the columns, rafters and haunches. Discrete decision variables were adopted for the thickness of the steel plates and continuous variables for the breadth and depth of the plates. Strategies were developed to enhance the performance of the GA including solution space reduction and a hybrid initial population half of which is derived using Latin hypercube sampling. The results show that the proposed GA-based optimisation model generates optimal and near-optimal solutions consistently. A parametric study is then conducted on frames of different spans. A significant variation in weight between fabricated and conventional hot-rolled steel portal frames is shown; for a 50 m span frame, a 14–19% saving in weight was achieved. Furthermore, since Universal Beam sections in the UK come from a discrete section library, the results could also provide overall dimensions of other beams that could be more efficient for portal frames. Eurocode 3 was used for illustrative purposes; any alternative code of practice may be used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new approach for global detection of seismic damage in a single-storey steel concentrically braced frame (CBF) structure is presented. The filtered lateral in-plane acceleration response of the CBF structure is integrated twice to provide the lateral in-plane displacement which is used to infer buckling and yielding damage. The level of interstorey drift of the CBF during a seismic excitation allows the yield and buckling of the bracing members to be identified and indirectly detects damage based on exceedance of calculated lateral in-plane displacement limits. A band-pass filter removes noise from the acceleration signal followed by baseline correction being used to reduce the drift in velocity and displacement during numerical integration. This pre-processing results in reliable numerical integration of the frame acceleration that predicts the displacement response accurately when compared to the measured lateral displacement of the CBF structure. Importantly, the structural damage is not assumed through removal of bracing members, rather damage is induced through actual seismic loading. The buckling and yielding displacement threshold limits used to identify damage are demonstrated to accurately identify the initiation of buckling and yielding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the simulation of representative aircraft wing stiffened panels under axial compression loading, to determine the effects of varying the manufacturing shape and assembly joining methods on stiffened panel performance. T-stiffened and Z-stiffened panels are modelled in Abaqus simulating integral, co-cured and mechanically fastened joints. The panels are subject to an edge compressive displacement along the stiffener axis until failure and the ultimate failure load and buckling performance is assessed for each. Integral panels consistently offer the highest performance. Co-cured panels demonstrate reduced performance (3-5% reduction in ultimate load relative to integral) caused by localised cohesive failure and skin-stiffener separation. The mechanically fastened panels are consistently the weakest joint (19-25% reduction in ultimate load relative to integral) caused primarily by inter-rivet buckling between fasteners

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reinforced concrete (RC) jacketing is a common method to retrofit existing columns with poor structural performance. It can be applied in two different ways: if the continuity of the jacket is ensured, the axial load of the column can be transferred to the jacket, which will be directly loaded; conversely, if no continuity is provided, the jacket induces only confinement action. In both cases the strength and ductility evaluation is rather complex, due to the different physical phenomena included, such as confinement, composite action core-jacket, preload, buckling of longitudinal bars.
Although different theoretical studies have been carried out to calculate the confinement effects, a practical approach to evaluate the flexural capacity and ductility is still missing. The calculation of these quantities is often related to the use of commercial computer programs, taking advantage of numerical methods such as fiber method or finite element method.
This paper presents a simplified approach to calculate the flexural strength and ductility of square RC jacketed sections subjected to axial load and bending moment. In particular the proposed approach is based on the calibration of the stress-block parameters including the confinement effect. Equilibrium equations are determined and buckling of longitudinal bars is modeled with a suitable stress-strain law. Moment-curvature curves are derived with simple calculations. Finally, comparisons are made with numerical analyses carried out with the code OpenSees and with experimental data available in the literature, showing good agreement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The design of current composite primary aerostructures, such as fuselage or wing stiffened panels, tends to be conservative due to the susceptibility of the relatively weak skin-stiffener interface. This weakness is due to through-thickness stresses which are exacerbated by deformations due to buckling. This paper presents a finite-elementbased optimization strategy, utilizing a global-local modelling approach, for postbuckling stiffened panels which takes into account damage mechanisms which may lead to delamination and subsequent failure of the panel due to stiffener debonding. A genetic algorithm was linked to a finite element package to automate the iterative procedure and maximize the damage resistance of the panel in postbuckling. For a given loading condition, the procedure optimized the panel’s skin layup leading to a design displaying superior damage resistance compared to non-optimized designs

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of a 100 mm diameter integrally-flanged hole in a hat-stiffenend carbon-fibre composite panel, loaded in uniaxial compression, were investigated and compared with a similar panel containing an unflanged hole. Details of the manufacturing techniques used in the production of the integral flange are presented. The stiffening effects of the flange reduced the bending strains, which may lead to high interlaminar shear strains, around the cutout while increasing the membrane strains. These membrane strains were well below the limit strains for this composite material. The skin in the unflanged hole also underwent a change in buckling mode shape from three longitudinal half-wavelengths to five half-wavelengths. No such change was observed in the flanged panel and this buckled in four longitudinal half-wavelengths. The ultimate strength of both panels was determined by the load carrying capability of the stiffeners.