Burial grounds are commonly surveyed and searched by both police/humanitarian search teams and archaeologists.
One aspect of an efficient search is to establish areas free of recent internments to allow the concentration of assets in suspect
terrain. While 100% surety in locating remains can never be achieved, the deployment of a red, amber green (RAG) system for
assessment has proven invaluable to our surveys. The RAG system is based on a desktop study (including burial ground
records), visual inspection (mounding, collapses) and use of geophysics (in this case, ground penetrating radar or GPR) for a
multi-proxy assessment that provides search authorities an assessment of the state of inhumations and a level of legal backup
for decisions they make on excavation or not (‘exit strategy’). The system is flexible and will be built upon as research
continues.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A tridimensional model of α-Fe2O3 and models of (0001) and (1102) surfaces on it were built. Then the structural optimization of the (0001) surface was presented which explored the influence of the system scale and the terminal surface configuration. Four different models including two different system scale structures (MODEL□ and MODEL□) and two different terminal structures (MODEL□ and MODEL□) were analyzed in this paper. It was concluded that the boundary effect was more important in a smaller system in the structure optimization. And the Fe-terminated was more stable than the O-terminated structure which was agreed with the experiences, this structural model can be used in further work including the monatomic adsorption/desorption and the chemical reactions on this surface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective
Based on the theory of incentive sensitization, the aim of this study was to investigate differences in attentional processing of food-related visual cues between normal-weight and overweight/obese males and females.

Methods
Twenty-six normal-weight (14M, 12F) and 26 overweight/obese (14M, 12F) adults completed a visual probe task and an eye-tracking paradigm. Reaction times and eye movements to food and control images were collected during both a fasted and fed condition in a counterbalanced design.

Results
Participants had greater visual attention towards high-energy-density food images compared to low-energy-density food images regardless of hunger condition. This was most pronounced in overweight/obese males who had significantly greater maintained attention towards high-energy-density food images when compared with their normal-weight counterparts however no between weight group differences were observed for female participants.

Conclusions
High-energy-density food images appear to capture visual attention more readily than low-energy-density food images. Results also suggest the possibility of an altered visual food cue-associated reward system in overweight/obese males. Attentional processing of food cues may play a role in eating behaviors thus should be taken into consideration as part of an integrated approach to curbing obesity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new perceptual watermarking model for Discrete Shearlet transform (DST). DST provides the optimal representation [10] of the image features based on multi-resolution and multi-directional analysis. This property can be exploited on for watermark embedding to achieve the watermarking imperceptibility by introducing the human visual system using Chou’s model. In this model, a spatial JND profile is adapted to fit the sub-band structure. The combination of DST and the Just-Noticeable Distortion (JND) profile improves the levels of robustness against certain attacks while minimizing the distortion; by assigning a visibility threshold of distortion to each DST sub-band coefficient in the case of grey scale image watermarking.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a hierarchical energy management system for multi-source multi-product (MSMP) microgrids. Traditional energy hub based scheduling method is combined with a hierarchical control structure to incorporate transient characteristics of natural gas flow and dynamics of energy converters in microgrids. The hierarchical EMS includes a supervisory control layer, an optimizing control layer, and an execution control layer. In order to efficiently accommodate the systems multi time-scale characteristics, the optimizing control layer is decomposed into three sub-layers: slow, medium and fast. Thermal, gas and electrical management systems are integrated into the slow, medium, and fast control layer, respectively. Compared with wind energy, solar energy is easier to integrate and more suitable for the microgrid environment, therefore, potential impacts of the hierarchical EMS on MSMP microgrids is investigated based on a building energy system integrating photovoltaic and microturbines. Numerical studies indicate that by using a hierarchical EMS, MSMP microgrids can be economically operated. Also, interactions among thermal, gas, and electrical system can be effectively managed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Holcus lanatus L. phosphate and arsenate are taken up by the same transport system. Short-term uptake kinetics of the high affinity arsenate transport system were determined in excised roots of arsenate-tolerant and non-tolerant genotypes. In tolerant plants the Vmax of ion uptake in plants grown in phosphate-free media was decreased compared to non-tolerant plants, and the affinity of the uptake system was lower than in the non-tolerant plants. Both the reduction in Vmax and the increase in Km led to reduced arsenate influx into tolerant roots. When the two genotypes were grown in nutrient solution containing high levels of phosphate, there was little change in the uptake kinetics in tolerant plants. In non-tolerant plants, however, there was a marked decrease in the Vmax to the level of the tolerant plants but with little change in the Km. This suggests that the low rate of arsenate uptake over a wide range of differing root phosphate status is due to loss of induction of the synthesis of the arsenate (phosphate) carrier. © 1992 Oxford University Press.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study proposes an approach to optimally allocate multiple types of flexible AC transmission system (FACTS) devices in market-based power systems with wind generation. The main objective is to maximise profit by minimising device investment cost, and the system's operating cost considering both normal conditions and possible contingencies. The proposed method accurately evaluates the long-term costs and benefits gained by FACTS devices (FDs) installation to solve a large-scale optimisation problem. The objective implies maximising social welfare as well as minimising compensations paid for generation re-scheduling and load shedding. Many technical operation constraints and uncertainties are included in problem formulation. The overall problem is solved using both particle swarm optimisations for attaining optimal FDs allocation as main problem and optimal power flow as sub-optimisation problem. The effectiveness of the proposed approach is demonstrated on modified IEEE 14-bus test system and IEEE 118-bus test system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we propose a sparse multi-carrier index keying (MCIK) method for orthogonal frequency division multiplexing (OFDM) system, which uses the indices of sparse sub-carriers to transmit the data, and improve the performance
of signal detection in highly correlated sub-carriers. Although a receiver is able to exploit a power gain with precoding in OFDM, the sensitivity of the signal detection is usually high as the orthogonality is not retained in highly dispersive
environments. To overcome this, we focus on developing the trade-off between the sparsity of the MCIK, correlation, and performances, analyzing the average probability of the error propagation imposed by incorrect index detection over highly correlated sub-carriers. In asymptotic cases, we are able to see how sparsity of MCIK should be designed in order to perform superior to the classical OFDM system. Based on this feature, sparse MCIK based OFDM is a better choice for low detection errors in highly correlated sub-carriers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the effect of an industrial scale continuous flow microwave volumetric heating system in comparison to conventional commercial scale pasteurisation for the processing of tomato juice in terms of physicochemical properties, microbial characteristics and antioxidant capacity. The effect against oxidative stress in Caco-2 cells, after in vitro digestion was also investigated. Physicochemical and colour characteristics of juices were very similar between technologies and during storage. Both conventional and microwave pasteurisation inactivated microorganisms and kept them in low levels throughout storage. ABTS+ values, but not ORAC, were higher for the microwave pasteurised juice at day 0 however no significant differences between juices were observed during storage. Juice processed with the microwave system showed an increased cytoprotective effect against H2O2 induced oxidation in Caco-2 cells. Organoleptic analysis revealed that the two tomato juices were very similar. The continuous microwave volumetric heating system appears to be a viable alternative to conventional pasteurisation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigated using lip movements as a behavioural biometric for person authentication. The system was trained, evaluated and tested using the XM2VTS dataset, following the Lausanne Protocol configuration II. Features were selected from the DCT coefficients of the greyscale lip image. This paper investigated the number of DCT coefficients selected, the selection process, and static and dynamic feature combinations. Using a Gaussian Mixture Model - Universal Background Model framework an Equal Error Rate of 2.20% was achieved during evaluation and on an unseen test set a False Acceptance Rate of 1.7% and False Rejection Rate of 3.0% was achieved. This compares favourably with face authentication results on the same dataset whilst not being susceptible to spoofing attacks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Poor follow-up after cataract surgery in developing countries makes assessment of operative quality uncertain. We aimed to assess two strategies to measure visual outcome: recording the visual acuity of all patients 3 or fewer days postoperatively (early postoperative assessment), and recording that of only those patients who returned for the final follow-up examination after 40 or more days without additional prompting. Methods: Each of 40 centres in ten countries in Asia, Africa, and Latin America recruited 40-120 consecutive surgical cataract patients. Operative-eye best-corrected visual acuity and uncorrected visual acuity were recorded before surgery, 3 or fewer days postoperatively, and 40 or more days postoperatively. Clinics logged whether each patient had returned for the final follow-up examination without additional prompting, had to be actively encouraged to return, or had to be examined at home. Visual outcome for each centre was defined as the proportion of patients with uncorrected visual acuity of 6/18 or better minus the proportion with uncorrected visual acuity of 6/60 or worse, and was calculated for each participating hospital with results from the early assessment of all patients and the late assessment of only those returning unprompted, with results from the final follow-up assessment for all patients used as the standard. Findings: Of 3708 participants, 3441 (93%) had final follow-up vision data recorded 40 or more days after surgery, 1831 of whom (51% of the 3581 total participants for whom mode of follow-up was recorded) had returned to the clinic without additional prompting. Visual outcome by hospital from early postoperative and final follow-up assessment for all patients were highly correlated (Spearman's rs=0·74, p<0·0001). Visual outcome from final follow-up assessment for all patients and for only those who returned without additional prompting were also highly correlated (rs=0·86, p<0·0001), even for the 17 hospitals with unprompted return rates of less than 50% (rs=0·71, p=0·002). When we divided hospitals into top 25%, middle 50%, and bottom 25% by visual outcome, classification based on final follow-up assessment for all patients was the same as that based on early postoperative assessment for 27 (68%) of 40 centres, and the same as that based on data from patients who returned without additional prompting in 31 (84%) of 37 centres. Use of glasses to optimise vision at the time of the early and late examinations did not further improve the correlations. Interpretation: Early vision assessment for all patients and follow-up assessment only for patients who return to the clinic without prompting are valid measures of operative quality in settings where follow-up is poor. Funding: ORBIS International, Fred Hollows Foundation, Helen Keller International, International Association for the Prevention of Blindness Latin American Office, Aravind Eye Care System. © 2013 Congdon et al. Open Access article distributed under the terms of CC BY.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess the impact of laser peripheral iridotomy (LPI) on forward-scatter of light and subjective visual symptoms and to identify LPI parameters influencing these phenomena. DESIGN: Cohort study derived from a randomized trial, using an external control group. PARTICIPANTS: Chinese subjects initially aged 50 or older and 70 years or younger with bilateral narrow angles undergoing LPI in 1 eye selected at random, and age- and gender-matched controls. METHODS: Eighteen months after laser, LPI-treated subjects underwent digital iris photography and photogrammetry to characterize the size and location of the LPI, Lens Opacity Classification System III cataract grading, and measurement of retinal straylight (C-Quant; OCULUS, Wetzlar, Germany) in the treated and untreated eyes and completed a visual symptoms questionnaire. Controls answered the questionnaire and underwent straylight measurement and (in a random one-sixth sample) cataract grading. MAIN OUTCOME MEASURES: Retinal straylight levels and subjective visual symptoms. RESULTS: Among 230 LPI-treated subjects (121 [58.8%] with LPI totally covered by the lid, 43 [19.8%] with LPI partly covered by the lid, 53 [24.4%] with LPI uncovered by the lid), 217 (94.3%) completed all testing, as did 250 (93.3%) of 268 controls. Age, gender, and prevalence of visual symptoms did not differ between treated subjects and controls, although nuclear (P<0.01) and cortical (P = 0.03) cataract were less common among controls. Neither presenting visual acuity nor straylight score differed between the treated and untreated eyes among all treated persons, nor among those (n = 96) with LPI partially or totally uncovered. Prevalence of subjective glare did not differ significantly between participants with totally covered LPI (6.61%; 95% confidence interval [CI], 3.39%-12.5%), partially covered LPI (11.6%; 95% CI, 5.07%-24.5%), or totally uncovered LPI (9.43%; 95% CI, 4.10%-10.3%). In regression models, only worse cortical cataract grade (P = 0.01) was associated significantly with straylight score, and no predictors were associated with subjective glare. None of the LPI size or location parameters were associated with straylight or subjective symptoms. CONCLUSIONS: These results suggests that LPI is safe regarding measures of straylight and visual symptoms. This randomized design provides strong evidence that treatment programs for narrow angles would be unlikely to result in important medium-term visual disability.