49 resultados para ultrasonic


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sonoluminescence (SL) involves the conversion of mechanical [ultra]sound energy into light. Whilst the phenomenon is invariably inefficient, typically converting just 10-4 of the incident acoustic energy into photons, it is nonetheless extraordinary, as the resultant energy density of the emergent photons exceeds that of the ultrasonic driving field by a factor of some 10 12. Sonoluminescence has specific [as yet untapped] advantages in that it can be effected at remote locations in an essentially wireless format. The only [usual] requirement is energy transduction via the violent oscillation of microscopic bubbles within the propagating medium. The dependence of sonoluminescent output on the generating sound field's parameters, such as pulse duration, duty cycle, and position within the field, have been observed and measured previously, and several relevant aspects are discussed presently. We also extrapolate the logic from a recently published analysis relating to the ensuing dynamics of bubble 'clouds' that have been stimulated by ultrasound. Here, the intention was to develop a relevant [yet computationally simplistic] model that captured the essential physical qualities expected from real sonoluminescent microbubble clouds. We focused on the inferred temporal characteristics of SL light output from a population of such bubbles, subjected to intermediate [0.5-2MPa] ultrasonic pressures. Finally, whilst direct applications for sonoluminescent light output are thought unlikely in the main, we proceed to frame the state-of-the- art against several presently existing technologies that could form adjunct approaches with distinct potential for enhancing present sonoluminescent light output that may prove useful in real world [biomedical] applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE OF REVIEW:

Recent studies underscore the importance of angle-closure glaucoma (ACG) as a cause of world blindness. A major contribution in assessing the true impact of this disease has been an article estimating the number of persons with occludable angles, angle closure, and blindness from ACG in China as 28.2 million, 9.1 million, and 1.7 million, respectively. Although these numbers are based on data from Singapore and Mongolia, which may be applied to China only with caution, they emphasize the blinding potential of ACG, which is three times as likely to be associated with blindness as open-angle glaucoma (OAG).

RECENT FINDINGS:

Recent reports in the Chinese literature on ACG prevalence suffer from definitional problems that would appear to lead to systematic overestimates of ACG prevalence and underestimates of OAG prevalence. Nonetheless, data from studies by Chinese investigators further emphasize the strong association between ACG and blindness, with fully 16% of subjects with ACG blind in one report-a far higher proportion than for OAG in China and elsewhere. The importance of topiramate as a cause of secondary angle closure has recently been understood, in part, because of a series of 19 such cases reported by investigators at the Food and Drug Administration.

SUMMARY:

Angle closure in this setting appears to be caused by uveal effusion and anterior rotation of the ciliary body with resultant closure of the angle. The condition is not always responsive to laser iridectomy, and elimination of the causative agent appears to be critical. Ultrasonic biomicroscopy is a potential new diagnostic modality for ACG, allowing the measurement of novel parameters, such as the angle opening distance (AOD) at 500 microm (AOD 500). The efficacy of such parameters in improving screening for ACG can only be established by prospective studies of potentially at-risk eyes. A number of novel treatments for AC and angle closure have recently been proposed, including cataract extraction, paracentesis, and argon laser iridoplasty. As with proposed new diagnostic modalities, the efficacy of these treatments remains to be demonstrated with prospective studies, ideally organized in a controlled, randomized fashion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE:

We sought to measure the impact of central corneal thickness (CCT), a possible risk factor for glaucoma damage, and corneal hysteresis, a proposed measure of corneal resistance to deformation, on various indicators of glaucoma damage.

DESIGN:

Observational study.

METHODS:

Adult patients of the Wilmer Glaucoma Service underwent measurement of hysteresis on the Reichert Ocular Response Analyzer and measurement of CCT by ultrasonic pachymetry. Two glaucoma specialists (H.A.Q., N.G.C.) reviewed the chart to determine highest known intraocular pressure (IOP), target IOP, diagnosis, years with glaucoma, cup-to-disk ratio (CDR), mean defect (MD), pattern standard deviation (PSD), glaucoma hemifield test (GHT), and presence or absence of visual field progression.

RESULTS:

Among 230 subjects, the mean age was 65 +/- 14 years, 127 (55%) were female, 161 (70%) were white, and 194 (85%) had a diagnosis of primary open-angle glaucoma (POAG) or suspected POAG. In multivariate generalized estimating equation models, lower corneal hysteresis value (P = .03), but not CCT, was associated with visual field progression. When axial length was included in the model, hysteresis was not a significant risk factor (P = .09). A thinner CCT (P = .02), but not hysteresis, was associated with a higher CDR at the most recent examination. Neither CCT nor hysteresis was associated with MD, PSD, or GHT "outside normal limits."

CONCLUSIONS:

Thinner CCT was associated with the state of glaucoma damage as indicated by CDR. Axial length and corneal hysteresis were associated with progressive field worsening.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the association between corneal hysteresis and axial length/refractive error among rural Chinese secondary school children. DESIGN: Cross-sectional cohort study. METHODS: Refractive error (cycloplegic auto-refraction with subjective refinement), central corneal thickness (CCT) and axial length (ultrasonic measurement), intraocular pressure (IOP), and corneal hysteresis (Reichert Ocular Response Analyzer) were measured on a rural school-based cohort of children. RESULTS: Among 1,233 examined children, the mean age was 14.7 +/- 0.8 years and 699 (56.7%) were girls. The mean spherical equivalent (n = 1,232) was -2.2 +/- 1.6 diopters (D), axial length (n = 643) was 23.7 +/- 1.1 mm, corneal hysteresis (n = 1,153) was 10.7 +/- 1.6 mm Hg, IOP (n = 1,153) was 17.0 +/- 3.4 mm Hg, and CCT (n = 1,226) was 553 +/- 33 microns. In linear regression models, longer axial length was significantly (P < .001 for both) associated with lower corneal hysteresis and higher IOP. Hysteresis in this population was significantly (P < .001) lower than has previously been reported for normal White children (n = 42, 12.3 +/- 1.3 mm Hg), when adjusting for age and gender. This difference did not appear to depend on differences in axial length between the populations, as it persists when only Chinese children with normal uncorrected vision are included. CONCLUSIONS: Prospective studies will be needed to determine if low hysteresis places eyes at risk for axial elongation secondary or if primary elongation results in lower hysteresis.