145 resultados para surface plasmon wave


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surface plasmon enhancement of laser ablation of thin Al films is examined with a view to its application in metal film patterning and nano-structuring. Al films, deposited on silica prisms, are first characterized by attenuated total reflection using a broadband UV source and appropriate interference filter. The films are subsequently subjected to excimer laser radiation of wavelength 248 nm under conditions both of direct incidence from the air side of the film, and of surface plasmon excitation in which light is incident through the prism at greater than critical angle. For a given level of ablation damage in a particular film the fluence required using the surface plasmon technique is 3-5 times less than that needed when direct incidence is used. This is roughly in line with the energy absorbed in the film. From a practical standpoint it is clear that ablation of metal films can be achieved with much lower fluences than has hitherto been possible, thus reducing the requirements on laser output and relaxing the power handling constraints on any input optical elements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The surface plasmon polariton mediated photoresponse from Al-GaAs diodes is examined in a prism-air gap-diode configuration as a function of both the wavelength of the incident light and thickness of the Al electrode. The experimental data shows a pronounced dip in reflectance as a function of internal angle of incidence in the prism, due to the excitation of the surface plasmon polariton at the Al-air interface, and a corresponding peak in device photosignal. Careful modelling of reflectance and quantum efficiency data shows that the bulk of the signal is generated by light which is re-radiated from this surface mode into the semiconductor substrate where it is absorbed by the creation of electron-hole pairs in the depletion region. This holds for all the wavelengths used here (all are shorter than the GaAs absorption edge) and across the thickness range of the Al electrodes (20-50 nm). Quantum efficiencies in the range 0.5-22% and enhancement factors of typically 7.5 were recorded in this investigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The radiative decay of surface plasmon polaritons has been investigated in an attempt to characterize the surface roughness of Ag films prepared under different conditions. The polaritons were excited by the method of attenuated total reflection of light. The films were deposited on the face of a 60-degrees BK-7 glass prism at a rate that was deliberately fixed in two different ranges (centred on 0.1 and 10 nm s-1) and in some cases a CaF2 underlayer was used to roughen the film surfaces. The intensity of the scattered light emitted from the opposite face of the films was measured as a function of direction for each using the same sensitivity scale and was correlated with the preparation of the film. It was found that on nominally smooth substrates fast-deposited thinner films give out more light and are deduced to have greater short wavelength (300-600 nm) roughness amplitude. There is also evidence for long wavelenth (7 mum) periodic roughness due to the prism substrate itself. On CaF2 roughened surfaces the light output from the films is further increased and the peak intensity is backward directed with respect to the exciting laser beam direction. Here roughness on a lateral scale of 350 nm is responsible. Also, elastic scattering of surface plasmon polaritons at grain boundaries reduces the light output from fast deposited, small grain, films on CaF2 roughened surfaces. Overall, a consistent picture of roughness induced radiative polariton decay emerges for all cases studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent experimental results definitively showed, for the first time, optical radiation mediated by the slow mode surface plasmon polariton of metal-oxide-metal tunnel junctions. Here, dispersion curves for this mode are calculated. They are consistent with first-order grating coupling to light at the energies of the experimental emission peaks. The curves are then used to analyze second-order and high-energy (> 2.35 eV) grating coupling of the polaritons to radiation. Finally, variation of slow mode damping as a function of energy is used to explain qualitatively the relative experimental peak emission intensities and the absence of radiation peaks above 2.35 eV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using a prism-air gap-sample (Otto) configuration we have optically excited surface plasmon polaritons at the Ag-air interface of passive Al-Al oxide-Ag tunnel junction structures at wavelength 632.8 nm. It is found that the internal damping of this excitation is more than a factor of 2 greater for samples with a very thin (approximately 15 nm) Ag electrode than for samples with a thicker (approximately 40 nm) Ag electrode. This observation is explained by the fact that the fields of the surface plasmon polariton penetrate more substantially into the lossy Al base electrode when the Ag top electrode is very thin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The increasing occurrence of puffer fish containing tetrodotoxin (TTX) in the Mediterranean could represent a major food safety risk for European consumers and threaten the fishing industry. The work presented herein describes the development of a new enzyme linked immunosorbent assay (mELISA) based on the immobilization of TTX through dithiol monolayers self-assembled on maleimide plates, which provides an ordered and oriented antigen immobilization and favors the antigen-antibody affinity interaction. The mELISA was found to have a limit of detection (LOD) of TTX of 0.23 mg/kg of puffer fish matrix. The mELISA and a surface plasmon resonance (SPR) immunosensor previously developed were employed to establish the cross-reactivity factors (CRFs) of 5,6,11-trideoxy-TTX, 5,11-deoxy-TTX, 11-nor-TTX-6-ol, and 5,6,11-trideoxy-4-anhydro-TTX, as well as to determine TTX equivalent contents in puffer fish samples. Results obtained by both immunochemical tools were correlated (R(2) = 0.977). The puffer fish samples were also analyzed using liquid chromatography-tandem mass spectrometry (LC-MS/MS), and the corresponding CRFs were applied to the individual TTX contents. Results provided by the immunochemical tools, when compared with those obtained by LC-MS/MS, showed a good degree of correlation (R(2) = 0.991 and 0.979 for mELISA and SPR, respectively). The mouse bioassay (MBA) slightly overestimated the CRF adjusted TTX content of samples when compared with the data obtained from the other techniques. The mELISA has been demonstrated to be fit for the purpose for screening samples in monitoring programs and in research activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Research in biosensing approaches as alternative techniques for food diagnostics for the detection of chemical contaminants and foodborne pathogens has increased over the last twenty years. The key component of such tests is the biorecognition element whereby polyclonal or monoclonal antibodies still dominate the market. Traditionally the screening of sera or cell culture media for the selection of polyclonal or monoclonal candidate antibodies respectively has been performed by enzyme immunoassays. For niche toxin compounds, enzyme immunoassays can be expensive and/or prohibitive methodologies for antibody production due to limitations in toxin supply for conjugate production. Automated, self-regenerating, chip-based biosensors proven in food diagnostics may be utilised as rapid screening tools for antibody candidate selection. This work describes the use of both single channel and multi-channel surface plasmon resonance (SPR) biosensors for the selection and characterisation of antibodies, and their evaluation in shellfish tissue as standard techniques for the detection of domoic acid, as a model toxin compound. The key advantages in the use of these biosensor techniques for screening hybridomas in monoclonal antibody production were the real time observation of molecular interaction and rapid turnaround time in analysis compared to enzyme immunoassays. The multichannel prototype instrument was superior with 96 analyses completed in 2h compared to 12h for the single channel and over 24h for the ELISA immunoassay. Antibodies of high sensitivity, IC50's ranging from 4.8 to 6.9ng/mL for monoclonal and 2.3-6.0ng/mL for polyclonal, for the detection of domoic acid in a 1min analysis time were selected. Although there is a progression for biosensor technology towards low cost, multiplexed portable diagnostics for the food industry, there remains a place for laboratory-based SPR instrumentation for antibody development for food diagnostics as shown herein.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Light of wavelength 632.8 nm and p-polarization is incident on a prism-air gap (varied from 0.7 to 7 mum)-Al-GaAs arrangement. Both the photosignal generated by the Schottky diode and the reflectance are measured as a function of the internal angle of incidence in the prism. There is significant, well-defined enhancement of the photosignal, up to a factor of approximately 7.5, associated with two different types of enhanced absorption modes. For air gaps <1.5 mum there is photosignal enhancement due to an enhanced absorption feature (reflectance dip) that occurs at an angle of incidence just above critical angle in the prism; this feature corresponds to the excitation of a surface plasmon polariton at the Al-air interface. For air gaps > 1 mum there are between one and ten photoresponse peaks at input angles less than the critical angle. The corresponding enhanced absorption features are due to leaky guided wave modes set up in the air gap.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We numerically study nonreciprocal regimes of surface plasmon-polariton at the interface between two gyrotropic media. We predict existence of isolated unidirectional TE and TM surface modes guided by the interface between gyroelectric and gyromagnetic media.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The complete spectrum of eigenwaves including surface plasmon polaritons (SPP), dynamic (bulk) and complex waves in the layered structures containing semiconductor and metallic films has been explored. The effects of loss, geometry and the parameters of dielectric layers on the eigenmode spectrum and, particularly, on the SPP modes have been analysed using both the asymptotic and rigorous numerical solutions of the full-wave dispersion equation. The field and Poynting vector distributions have been examined to identify the modes and elucidate their properties. It has been shown that losses and dispersion of permittivity qualitatively alter the spectral content and the eigenwave properties. The SPP counter-directional power fluxes in the film and surrounding dielectrics have been attributed to vortices of power flow, which are responsible for the distinctive features of SPP modes. It has been demonstrated for the first time that the maximal attainable slow-wave factor of the SPP modes guided by thin Au films at optical frequencies is capped not by losses but the frequency dispersion of the actual Au permittivity. © 2009 EDP Sciences.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We simulate the localized surface plasmon resonances of an Au nanoparticle within tunnelling proximity of an Au substrate. The results demonstrate that the calculated resonance energies can be identified with those experimentally detected for light emission from the tip-sample junction of a scanning tunnelling microscope. Relative to the modes of an isolated nanoparticle these modes show significant red-shifting, extending further into the infrared with increasing radius, primarily due to a proximity-induced lowering of the effective bulk plasmon frequency. Spatial mapping of the field enhancement factor shows an oscillatory variation of the field, absent in the case of a dielectric substrate; also the degree of localization of the modes, and thus the resolution achievable electromagnetically, is shown to depend primarily on the nanoparticle radius, which is only weakly dependent on wavelength.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Optical techniques toward the realization of sensitive and selective biosensing platforms have received considerable attention in recent times. Techniques based on interferometry, surface plasmon resonance, and waveguides have all proved popular, while spectroscopy in particular offers much potential. Raman spectroscopy is an information-rich technique in which the vibrational frequencies reveal much about the structure of a compound, but it is a weak process and offers poor sensitivity. In response to this problem, surface-enhanced Raman scattering (SERS) has received much attention, due to significant increases in sensitivity instigated by bringing the sample into contact with an enhancing substrate. Here we discuss a facile and rapid technique for the detection of pterins using SERS-active colloidal silver suspensions. Pterins are a family of biological compounds that are employed in nature in color pigmentation and as facilitators in metabolic pathways. In this work, small volumes of xanthopterin, isoxanthopterin, and 7,8-dihydrobiopterin have been examined while adsorbed to silver colloids. Limits of detection have been examined for both xanthopterin and isoxanthopterin using a 10-s exposure to a 12 mW 532 nm laser, which, while showing a trade-off between scan time and signal intensity, still provides the opportunity for the investigation of simultaneous detection of both pterins in solution. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3600658]

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Prothrombin interacts with phosphatidylserine containing platelet membranes via its N-terminal, gamma-carboxyglutamate (gla) residue-rich domain. Once bound it is cleaved to form the active protease, thrombin (factor IIa). Human prothrombin was cleaved with cathepsin G in the absence of calcium and magnesium ions. Under these conditions, the gla domain was removed. Phospholipid protected the protein from this proteolytic event, and this suggests that a conformational change may be induced by interaction with phospholipids. Binding of prothrombin to a surface containing 20% phosphatidylserine/80% phosphatidylcholine was detected by surface plasmon resonance, whereas no interaction with gla-domainless prothrombin was observed. Binding of intact prothrombin in the presence of calcium ions showed complex association kinetics, suggesting multiple modes of initial interaction with the surface. The kinetics of the dissociation phase could be fitted to a two-phase, exponential decay. This implies that there are at least two forms of the protein on the surface one of which dissociates tenfold more slowly than the other. Taken together, these data suggest that, on binding to a membrane surface, prothrombin undergoes a conformational change to a form which binds more tightly to the membrane.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work, we have shown that a 100 MHz Love wave device can be used to determine whether room temperature ionic liquids (RTILs) are Newtonian fluids and have developed a technique that allows the determination of the density-viscosity product, rho eta of a Newtonian RTIL. In addition, a test for a Newtonian response was established by relating the phase change to insertion loss change. Five concentrations of a water-miscible RTIL and seven pure RTILs were measured. The changes in phase and insertion loss were found to vary linearly with the square root of the density-viscosity product for values up to (rho eta)(1/2) similar to 10 kg m(-2) s(-1/2). The square root of the density-viscosity product was deduced from the changes in either phase or insertion loss using glycerol as a calibration liquid. In both cases, the deduced values of rho eta agree well with those measured using viscosity and density meters. Miniaturization of the device, beyond that achievable with the lower-frequency quartz crystal microbalance approach, to measure smaller volumes is possible. The ability to fabricate Love wave and other surface acoustic wave sensors using planar metallization technologies gives potential for future integration into lab-on-a-chip analytical systems for characterizing ionic liquids.