90 resultados para smaltimento reflui on-site sanitation madagascar
Resumo:
Research to date has identified incubator units as an effective mechanism for supporting the growth and development of small entrepreneurial firms. Advantages are gained not only from the provision of appropriate facilities and external managerial expertise on site, but also from the opportunity to develop entrepreneurial networks facilitated by the spatial proximity of incubator firms. Therefore, the research question upon which the paper is based investigates the impact of context, in other words the degree to which the networking opportunities provided by the university incubator support the small firm in its pursuit of sustainability and growth
Resumo:
We study the existence and stability of multisite discrete breathers in two prototypical non-square Klein-Gordon lattices, namely a honeycomb and a hexagonal one. In the honeycomb case we consider six-site configurations and find that for soft potential and positive coupling the out-of-phase breather configuration and the charge-two vortex breather are linearly stable, while the in-phase and charge-one vortex states are unstable. In the hexagonal lattice, we first consider three-site configurations. In the case of soft potential and positive coupling, the in-phase configuration is unstable and the charge-one vortex is linearly stable. The out-of-phase configuration here is found to always be linearly unstable. We then turn to six-site configurations in the hexagonal lattice. The stability results in this case are the same as in the six-site configurations in the honeycomb lattice. For all configurations in both lattices, the stability results are reversed in the setting of either hard potential or negative coupling. The study is complemented by numerical simulations which are in very good agreement with the theoretical predictions. Since neither the form of the on-site potential nor the sign of the coupling parameter involved have been prescribed, this description can accommodate inverse-dispersive systems (e. g. supporting backward waves) such as transverse dust-lattice oscillations in dusty plasma (Debye) crystals or analogous modes in molecular chains.
Resumo:
The performance of the surface zone of concrete is acknowledged as a major factor governing the rate of deterioration of reinforced concrete structures as it provides the only barrier to the ingress of water containing dissolved ionic species such as chlorides which, ultimately, initiate corrosion of the reinforcement. In-situ monitoring of cover-zone concrete is therefore critical in attempting to make realistic predictions as to the in-service performance of the structure. To this end, this paper presents developments in a remote interrogation system to allow continuous, real-time monitoring of the cover-zone concrete from an office setting. Use is made of a multi-electrode array embedded within cover-zone concrete to acquire discretized electrical resistivity and temperature measurements, with both parameters monitored spatially and temporally. On-site instrumentation, which allows remote interrogation of concrete samples placed at a marine exposure site, is detailed, together with data handling and processing procedures. Site-measurements highlight the influence of temperature on electrical resistivity and an Arrhenius-based temperature correction protocol is developed using on-site measurements to standardize resistivity data to a reference temperature; this is an advancement over the use of laboratory-based procedures. The testing methodology and interrogation system represents a robust, low-cost and high-value technique which could be deployed for intelligent monitoring of reinforced concrete structures.
Resumo:
With greater emphasis now being placed on the durability of concrete and the need for on-site characterization of concrete for durability, there is an increasing dependence on the measurement of the permeation properties of concrete. Such properties can be measured in the laboratory under controlled ambient conditions, namely, temperature and relative humidity, and comparisons made between samples not affected by testing conditions. An important factor that influences permeation measurements is the moisture state of the concrete prior to testing. Moisture gradients are known to exist in exposed concretes; therefore, all laboratory tests are generally carried out after preconditioning to a reference moisture state. This is reasonably easy to achieve in the laboratory, but more difficult to carry out on-site. Different methods of surface preconditioning in situ concrete are available; however, there is no general agreement on the suitability of any one method. Therefore, a comprehensive set of experiments was carried out with four different preconditioning methods. Results from these investigations indicated that only superficial drying could be achieved by using any of the preconditioning methods investigated and that significant moisture movement below a depth of 15 mm was not evident.
Resumo:
Numerous methods are available to measure the permeation properties of concrete, which can be classified in terms of the diffusion, absorption and permeability properties. The results from these tests are generally used to infer 'quality' or relative durability. Some of these tests involve the laboratory assessment of a sample of concrete extracted from the structure. However, this Technical Note concentrates on the alternative methods appropriate for use on site. Guidance is given on the choice of an appropriate test method, which in most practical situations depends on the predominant mechanism acting on the concrete under consideration.
Resumo:
This project involves the construction of a dwelling in the outskirts of Dublin City. Situated in a disused quarry, the house act as an inhabited bridge, spanning between natural and man made outcrops, service structures and a shared entrance staircase. The houses language derives from the structure necessary to achieve these spans.
The section internally is modeled to present a variety of scales of spaces. More intimate living spaces and bedrooms occur in a lower, north-facing wing. Taller living spaces address the south.
Incorporating rainwater harvesting, wood-gasifying boilers, on site wind powered electrical generation, solar thermal panels and very high levels of insulation the houses are close to energy neutral. The fact that the house is constructed in massive timber construction means that 250 tonnes of carbon are sequestered in its construction. The design includes a 25yar replanting strategy to replace the existing coniferous-forested surrounds with native species in a coppiced planting strategy to allow ongoing fuel for the house, and cash crops to be sold on.
Located in an area of outstanding natural beauty the planning and design of the house involved research into patterns of rural development, the relationship between man made interventions and the natural landscape and the technology of the vernacular. This latter research forms part of the themes being explored under the Kevin Kieran Arts Council / OPW Bursary
Aims / Objectives Questions
1 To design and construct a low energy place to dwell.
2 To investigate the relationship between man-made interventions and new construction in an area of outstanding natural beauty.
3 To derive a language of construction that is contemporary in nature but refers to precedents embedded in the vernacular.
4 To develop a low-carbon form of construction that allows the construction of the house to act to sequester carbon
5 To make a contemporary addition in sympathy with the qualities of the existing site
Resumo:
We compare two approaches for estimating the distribution of consumers' willingness to pay (WTP) in discrete choice models. The usual procedure is to estimate the distribution of the utility coefficients and then derive the distribution of WTP, which is the ratio of coefficients. The alternative is to estimate the distribution of WTP directly. We apply both approaches to data on site choice in the Alps. We find that the alternative approach fits the data better, reduces the incidence of exceedingly large estimated WTP values, and provides the analyst with greater control in specifying and testing the distribution of WTP. © 2008 Agricultural and Applied Economics Association.
Resumo:
Context: Nursing home residents with pneumonia are frequently hospitalized. Such transfers may be associated with multiple hazards of hospitalization as well as economic costs. Objective: To assess whether using a clinical pathway for on-site treatment of pneumonia and other lower respiratory tract infections in nursing homes could reduce hospital admissions, related complications, and costs. Design, Setting, and Participants: A cluster randomized controlled trial of 680 residents aged 65 years or older in 22 nursing homes in Hamilton, Ontario, Canada. Nursing homes began enrollment between January 2, 2001, and April 18, 2002, with the last resident follow-up occurring July 4, 2005. Residents were eligible if they met a standardized definition of lower respiratory tract infection. Interventions: Treatment in nursing homes according to a clinical pathway, which included use of oral antimicrobials, portable chest radiographs, oxygen saturation monitoring, rehydration, and close monitoring by a research nurse, or usual care. Main Outcome Measures: Hospital admissions, length of hospital stay, mortality, health-related quality of life, functional status, and cost. Results: Thirty-four (10%) of 327 residents in the clinical pathway group were hospitalized compared with 76 (22%) of 353 residents in the usual care group. Adjusting for clustering of residents in nursing homes, the weighted mean reduction in hospitalizations was 12% (95% confidence interval [CI], 5%-18%; P=.001). The mean number of hospital days per resident was 0.79 in the clinical pathway group vs 1.74 in the usual care group, with a weighted mean difference of 0.95 days per resident (95% CI, 0.34-1.55 days; P=.004). The mortality rate was 8% (24 deaths) in the clinical pathway group vs 9% (32 deaths) in the usual care group, with a weighted mean difference of 2.9% (95% CI, -2.0% to 7.9%; P=.23). There were no significant differences between the groups in health-related quality of life or functional status. The clinical pathway resulted in an overall cost savings of US $1016 per resident (95% CI, $207-$1824) treated. Conclusion: Treating residents of nursing homes with pneumonia and other lower respiratory tract infections with a clinical pathway can result in comparable clinical outcomes, while reducing hospitalizations and health care costs. ©2006 American Medical Association. All rights reserved.
Resumo:
The study details the development of a fully validated, rapid and portable sensor based method for the on-site analysis of microcystins in freshwater samples. The process employs a novel lysis method for the mechanical lysis of cyanobacterial cells, with glass beads and a handheld frother in only 10min. The assay utilises an innovative planar waveguide device that, via an evanescent wave excites fluorescent probes, for amplification of signal in a competitive immunoassay, using an anti-microcystin monoclonal with cross-reactivity against the most common, and toxic variants. Validation of the assay showed the limit of detection (LOD) to be 0.78ngmL and the CCß to be 1ngmL. Robustness of the assay was demonstrated by intra- and inter-assay testing. Intra-assay analysis had % C.V.s between 8 and 26% and recoveries between 73 and 101%, with inter-assay analysis demonstrating % C.V.s between 5 and 14% and recoveries between 78 and 91%. Comparison with LC-MS/MS showed a high correlation (R=0.9954) between the calculated concentrations of 5 different Microcystis aeruginosa cultures for total microcystin content. Total microcystin content was ascertained by the individual measurement of free and cell-bound microcystins. Free microcystins can be measured to 1ngmL, and with a 10-fold concentration step in the intracellular microcystin protocol (which brings the sample within the range of the calibration curve), intracellular pools may be determined to 0.1ngmL. This allows the determination of microcystins at and below the World Health Organisation (WHO) guideline value of 1µgL. This sensor represents a major advancement in portable analysis capabilities and has the potential for numerous other applications.