59 resultados para single particle, mass spectrometry, cluster analysis
Resumo:
The use of a charged-particle microbeam provides a unique opportunity to control precisely, the number of particles traversing individual cells and the localization of dose within the cell. The accuracy of 'aiming' and of delivering a precise number of particles crucially depends on the design and implementation of the collimation and detection system. This report describes the methods available for collimating and detecting energetic particles in the context of a radiobiological microbeam. The arrangement developed at the Gray Laboratory uses either a 'V'-groove or a thick-walled glass capillary to achieve 2-5 mu m spatial resolution. The particle detection system uses an 18 mu m thick transmission scintillator and photomultiplier tube to detect particles with >99% efficiency.
Resumo:
Recent evidence suggests that genomic instability, which is an important step in carcinogenesis, may be important in the effectiveness of radiation as a carcinogen, particularly for high-LET radiations. Understanding the biological effects underpinning the risks associated with low doses of densely ionizing radiations is complicated in experimental systems by the Poisson distribution of particles that ran be delivered, In this study, we report an approach to determine the effect of the lowest possible cellular radiation dose of densely ionizing at particles, that of a single particle traversal. Using microbeam technology and an approach for immobilizing human T-lymphocytes, we have measured the effects of single alpha -particle traversals on the surviving progeny of cells. A significant increase in the proportion of aberrant cells is observed 12-13 population doublings after exposure, with a high level of chromatid-type aberrations, indicative of an instability phenotype, These data suggest that instability may be important in situations where even a single particle traverses human cells. (C) 2001 by Radiation Research Society.
Resumo:
Computer-assisted topology predictions are widely used to build low-resolution structural models of integral membrane proteins (IMPs). Experimental validation of these models by traditional methods is labor intensive and requires modifications that might alter the IMP native conformation. This work employs oxidative labeling coupled with mass spectrometry (MS) as a validation tool for computer-generated topology models. ·OH exposure introduces oxidative modifications in solvent-accessible regions, whereas buried segments (e.g., transmembrane helices) are non-oxidizable. The Escherichia coli protein WaaL (O-antigen ligase) is predicted to have 12 transmembrane helices and a large extramembrane domain (Pérez et al., Mol. Microbiol. 2008, 70, 1424). Tryptic digestion and LC-MS/MS were used to map the oxidative labeling behavior of WaaL. Met and Cys exhibit high intrinsic reactivities with ·OH, making them sensitive probes for solvent accessibility assays. Overall, the oxidation pattern of these residues is consistent with the originally proposed WaaL topology. One residue (M151), however, undergoes partial oxidation despite being predicted to reside within a transmembrane helix. Using an improved computer algorithm, a slightly modified topology model was generated that places M151 closer to the membrane interface. On the basis of the labeling data, it is concluded that the refined model more accurately reflects the actual topology of WaaL. We propose that the combination of oxidative labeling and MS represents a useful strategy for assessing the accuracy of IMP topology predictions, supplementing data obtained in traditional biochemical assays. In the future, it might be possible to incorporate oxidative labeling data directly as constraints in topology prediction algorithms.
Resumo:
The composition of a dynamic mixture of similar 2,2'-bipyridine complexes of iron(II) bearing either an amide (5-benzylamido-2,2'-bipyridine and 5-(2-methoxyethane)amido-2,2'-bipyridine) or an ester (2,2'-bipyridine-5-carboxylic acid benzylester and 2,2'-bipyridine-5-carboxylic acid 2-methoxyethane ester) side chain have been evaluated by electrospray mass spectroscopy in acetonitrile. The time taken for the complexes to come to equilibrium appears to be dependent on the counteranion, with chloride causing a rapid redistribution of two preformed heteroleptic complexes (of the order of 1 hour), whereas the time it takes in the presence of tetrafluoroborate salts is in excess of 24^^h. Similarly the final distribution of products is dependent on the anion present, with the presence of chloride, and to a lesser extent bromide, preferring three amide-functionalized ligands, and a slight preference for an appended benzyl over a methoxyethyl group. Furthermore, for the first time, this study shows that the distribution of a dynamic library of metal complexes monitored by ESI-MS can adapt following the introduction of a different anion, in this case tetrabutylammonium chloride to give the most favoured heteroleptic complex despite the increasing ionic strength of the solution.
Resumo:
Essential to the conduct of epidemiologic studies examining aflatoxin exposure and the risk of heptocellular carcinoma, impaired growth, and acute toxicity has been the development of quantitative biomarkers of exposure to aflatoxins, particularly aflatoxin B-1. In this study, identical serum sample sets were analyzed for aflatoxin-albumin adducts by ELISA, high-performance liquid chromatography (HPLC) with fluorescence detection (HPLC-f), and HPLC with isotope dilution mass spectrometry (IDMS). The human samples analyzed were from an acute aflatoxicosis outbreak in Kenya in 2004 (n = 102) and the measured values ranged from 0.018 to 67.0, nondetectable to 13.6, and 0.002 to 17.7 ng/mg albumin for the respective methods. The Deming regression slopes for the HPLC-f and ELISA concentrations as a function of the IDMS concentrations were 0.71 (r(2) = 0.95) and 3.3 (r(2) = 0.96), respectively. When the samples were classified as cases or controls, based on clinical diagnosis, all methods were predictive of outcome (P < 0.01). Further, to evaluate assay precision, duplicate samples were prepared at three levels by dilution of an exposed human sample and were analyzed on three separate days. Excluding one assay value by ELISA and one assay by HPLC-f, the overall relative SD were 8.7%, 10.5%, and 9.4% for IDMS, HPLC-f, and ELISA, respectively. IDMS was the most sensitive technique and HPLC-f was the least sensitive method. Overall, this study shows an excellent correlation between three independent methodologies conducted in different laboratories and supports the validation of these technologies for assessment of human exposure to this environmental toxin and carcinogen.
Resumo:
Heterocyclic aromatic amines (HCA) are carcinogenic mutagens formed during cooking of proteinaceous foods, particularly meat. To assist in the ongoing search for biomarkers of HCA exposure in blood, a method is described for the extraction from human plasma of the most abundant HCAs: 2-Amino-1-methyl-6-phenylimidazo(4,5-b)pyridine (PhIP), 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx) and 2-amino-3,4,8-trimethylimidazo[4,5-f]quinoxaline (4,8-DiMeIQx) (and its isomer 7,8-DiMeIQx), using Hollow Fibre Membrane Liquid-Phase Microextraction. This technique employs 2.5 cm lengths of porous polypropylene fibres impregnated with organic solvent to facilitate simultaneous extraction from an alkaline aqueous sample into a low volume acidic acceptor phase. This low cost protocol is extensively optimised for fibre length, extraction time, sample pH and volume. Detection is by UPLC-MS/MS using positive mode electrospray ionisation with a 3.4 min runtime, with optimum peak shape, sensitivity and baseline separation being achieved at pH 9.5. To our knowledge this is the first description of HCA chromatography under alkaline conditions. Application of fixed ion ratio tolerances for confirmation of analyte identity is discussed. Assay precision is between 4.5 and 8.8% while lower limits of detection between 2 and 5 pg/mL are below the concentrations postulated for acid-labile HCA-protein adducts in blood.
Resumo:
Rai, D., Koidis, A., Rawson, A., McLouglin, P., Brunton, N. (2010). Characterisation of polyacetylenes in carrot extracts using electrospray ionisation quadrupole time of flight mass spectrometry. Delegate CD-Rom PS2.8, EFFoST Annual Meeting, Dublin, Ireland, 10 -12/11/2010 (Poster).
Novel Metabolite Biomarkers of Huntington's Disease As Detected by High-Resolution Mass Spectrometry
Resumo:
Huntington's disease (HD) is a fatal autosomal-dominant neurodegenerative disorder that affects approximately 3-10 people per 100 000 in the Western world. The median age of onset is 40 years, with death typically following 15-20 years later. In this study, we biochemically profiled post-mortem frontal lobe and striatum from HD sufferers (n = 14) and compared their profiles with controls (n = 14). LC-LTQ-Orbitrap-MS detected a total of 5579 and 5880 features for frontal lobe and striatum, respectively. An ROC curve combining two spectral features from frontal lobe had an AUC value of 0.916 (0.794 to 1.000) and following statistical cross-validation had an 83% predictive accuracy for HD. Similarly, two striatum biomarkers gave an ROC AUC of 0.935 (0.806 to 1.000) and after statistical cross-validation predicted HD with 91.8% accuracy. A range of metabolite disturbances were evident including but-2-enoic acid and uric acid, which were altered in both frontal lobe and striatum. A total of seven biochemical pathways (three in frontal lobe and four in striatum) were significantly altered as a result of HD. This study highlights the utility of high-resolution metabolomics for the study of HD. Further characterization of the brain metabolome could lead to the identification of new biomarkers and novel treatment strategies for HD.
Resumo:
The adulteration of food has received substantial amounts of media attention in the last few years, with events such as the European horsemeat scandal in 2013 sending shockwaves through society. Almost all cases are motivated by the pursuit of profits and are often aided by long and complex supply chains. In the past few years, the rapid growth of ambient mass spectrometry (AMS) has been remarkable, with over thirty different ambient ionisation techniques available. Due to the increasing concerns of the food industry and regulators worldwide, AMS is now being utilised to investigate whether or not it can generate results which are faster yet comparable to those of conventional techniques. This article reviews some aspects of the adulteration of food and its impact on the economy and the public's health, the background to ambient mass spectrometry and the studies that have been undertaken to detect food adulteration using this technology.
Resumo:
Residents of certain areas of Tanzania are exposed to mycotoxins through the consumption of contaminated maize based foods. In this study, 101 maize based porridge samples were collected from villages of Nyabula, Kikelelwa and Kigwa located in different agro-ecological zones of Tanzania. The samples were collected at three time points (time point 1, during maize harvest; time point 2, 6 months after harvest; time point 3, 12 months after harvest) over a 1-year period. Ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was used to detect and quantify 9 mycotoxins: aflatoxin B1 (AFB1), aflatoxin B2 (AFB2), aflatoxin G1 (AFG1), aflatoxin G2 (AFG2), fumonisin B1 (FB1), fumonisin B2 (FB2), deoxynivalenol (DON), ochratoxin A (OTA) and zearaleneone (ZEN) in the samples following a QuEChERS extraction method. Eighty two percent of samples were co-contaminated with more than one group of mycotoxins. Fumonisins (FB1 + FB2) had the highest percentage occurrence in all 101 samples (100%) whereas OTA had the lowest (5%). For all three villages the mean concentration of FB1 was lowest in samples taken from time point 2. Conversely, In Kigwa village there was a distinct trend that AFB1 mean concentration was highest in samples taken from time point 2. DON concentration did not differ greatly between time points but the percentage occurrence varied between villages, most notably in Kigwa where 0% of samples tested positive. ZEN occurrence and mean concentration was highest in Kikelelwa. The results suggest that mycotoxin contamination in maize can vary based on season and agro-ecological zones. The high occurrence of multiple mycotoxins found in maize porridge, a common weaning food in Tanzania, presents a potential increase in the risk of exposure and significant health implications in children.
Resumo:
A new radiocarbon preparation facility was set up in 2010 at the Godwin Laboratory for Palaeoclimate Research, at the University of Cambridge. Samples are graphitized via hydrogen reduction on an iron powder catalyst before being sent to the Chrono Centre, Belfast, or the Australian National University for accelerator mass spectrometry (AMS) analysis. The experimental setup and procedure have recently been developed to investigate the potential for running small samples of foraminiferal carbonate. By analyzing background values of samples ranging from 0.04 to 0.6 mg C along with similar sized secondary standards, the setup and experimental procedures were optimized for small samples. “Background” modern 14C contamination has been minimized through careful selection of iron powder, and graphitization has been optimized through the use of “small volume” reactors, allowing samples containing as little as 0.08 mg C to be graphitized and accurately dated. Graphitization efficiency/fractionation is found not to be the main limitation on the analysis of samples smaller than 0.07 mg C, which rather depends primarily on AMS ion beam optics, suggesting further improvements in small sample analysis might yet be achieved with our methodology.