80 resultados para progetto PCB nodo sensore wireless ultra low power monitoraggio della temperatura


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel open-ended waveguide cavity resonator for the microwave curing of bumps, underfills and encapsulants is described. The open oven has the potential to provide fast alignment of devices during flip-chip assembly, direct chip attach, surface mount assembly or wafer-scale level packaging. The prototype microwave oven was designed to operate at X-band for ease of testing, although a higher frequency version is planned. The device described in the paper takes the form of a waveguide cavity resonator. It is approximately square in cross-section and is filled with a low-loss dielectric with a relative permittivity of 6. It is excited by end-fed probes in order to couple power preferentially into the TM3,3,k mode with the object of forming nine 'hot-spots' in the open end. Low power tests using heat sensitive film demonstrate clearly that selective heating in multiple locations in the open end of the oven is achievable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Plasma ionization, and associated mode transitions, in dual radio-frequency driven atmospheric pressure plasmas are governed through nonlinear frequency coupling in the dynamics of the plasma boundary sheath. Ionization in low-power mode is determined by the nonlinear coupling of electron heating and the momentary local plasma density. Ionization in high-power mode is driven by electron avalanches during phases of transient high electric fields within the boundary sheath. The transition between these distinctly different modes is controlled by the total voltage of both frequency components.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of a reflective, gold-coated long-period grating-based sensor for the measurement of chloride ions in solution is discussed. The sensor scheme is based around a long-period fiber grating (LPG)-based Michelson interferometer where the sensor was calibrated and evaluated in the laboratory using sodium chloride solutions, over a wide range of concentrations, from 0.01 to 4.00 M. The grating response creates shifts in the spectral characteristic of the interferometer, formed using the LPG and a reflective surface on the distal end of the fiber, due to the change of refracting index of the solution surrounding it. It was found that the sensitivity of the device could be enhanced over that obtained from a bare fiber by coating the LPG-based interferometer with gold nanoparticles and the results of a cross-comparison of performance were obtained and details discussed. The approach will be explored as a basis to create a portable, low-power device, developed with the potential for installation in concrete structures to determine the ingress of chloride ions, operating through monitoring the refractive index change.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

All-optical signal processing enables modulation and transmission speeds not achievable using electronics alone(1,2). However, its practical applications are limited by the inherently weak nonlinear effects that govern photon-photon interactions in conventional materials, particularly at high switching rates(3). Here, we show that the recently discovered nonlocal optical behaviour of plasmonic nanorod metamaterials(4) enables an enhanced, ultrafast, nonlinear optical response. We observe a large (80%) change of transmission through a subwavelength thick slab of metamaterial subjected to a low control light fluence of 7 mJ cm(-2), with switching frequencies in the terahertz range. We show that both the response time and the nonlinearity can be engineered by appropriate design of the metamaterial nanostructure. The use of nonlocality to enhance the nonlinear optical response of metamaterials, demonstrated here in plasmonic nanorod composites, could lead to ultrafast, low-power all-optical information processing in subwavelength-scale devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Plasma diagnostics of atmospheric plasmas is a key tool in helping to understand processing performance issues. This paper presents an electrical, optical and thermographic imaging study of the PlasmaStream atmospheric plasma jet system. The system was found to exhibit three operating modes; one constricted/localized plasma and two extended volume plasmas. At low power and helium flows the plasma is localized at the electrodes and has the electrical properties of a corona/filamentary discharge with electrical chaotic temporal structure. With increasing discharge power and helium flow the plasma expands into the volume of the tube, becoming regular and homogeneous in appearance. Emission spectra show evidence of atomic oxygen, nitric oxide and the hydroxyl radical production. Plasma activated gas temperature deduced from the rotational temperature of nitrogen molecules was found to be of order of 400 K: whereas thermographic imaging of the quartz tube yielded surface temperatures between 319 and 347 K.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present paper demonstrates the suitability of artificial neural network (ANN) for modelling of a FinFET in nano-circuit simulation. The FinFET used in this work is designed using careful engineering of source-drain extension, which simultaneously improves maximum frequency of oscillation f(max) because of lower gate to drain capacitance, and intrinsic gain A(V0) = g(m)/g(ds), due to lower output conductance g(ds). The framework for the ANN-based FinFET model is a common source equivalent circuit, where the dependence of intrinsic capacitances, resistances and dc drain current I-d on drain-source V-ds and gate-source V-gs is derived by a simple two-layered neural network architecture. All extrinsic components of the FinFET model are treated as bias independent. The model was implemented in a circuit simulator and verified by its ability to generate accurate response to excitations not used during training. The model was used to design a low-noise amplifier. At low power (J(ds) similar to 10 mu A/mu m) improvement was observed in both third-order-intercept IIP3 (similar to 10 dBm) and intrinsic gain A(V0) (similar to 20 dB), compared to a comparable bulk MOSFET with similar effective channel length. This is attributed to higher ratio of first-order to third-order derivative of I-d with respect to gate voltage and lower g(ds), in FinFET compared to bulk MOSFET. Copyright (C) 2009 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

User induced errors are common when women repetitively employ conventional probe type thermometers to chart their basal body temperatures in an effort to indicate ovulation. An alternative technique employing a two-part telemetric thermometer is proposed, with low-power, SAWR-controlled UHF radio as the transmission medium. Worn overnight in the vagina, the 1 mu W erp telemetry transmitter sends pulse modulated data continuously to a microcontroller in a nearby receiver; a real time clock enables programmable sampling and storage of the subject's temperature to 0.1 degrees C resolution. Initial clinical results indicate an enhanced performance compared to oral and axillary temperature trends taken by a mercury-in-glass thermometer. Polar plots of both the isolated and body-worn telemetry transmitte are presented; body indced attenuations of up to 30 dB were measured.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A vaginally-worn temperature telemeter may be used by women to chart their basal body temperature for ovulation detection. The telemeter uses a temperature to pulse width converter to key a Colpitts oscillator which is controlled in frequency by a 418 MHz SAW resonator. The circuit’s tank inductor acts as a compact, multi-turn loop antenna with a radiated power in isolation of around 1 uW. The transmission characteristics of the system are affected by the proximity of the human body, which acts as an electrically-large lossy dielectric. The RF link-budget must allow for the reduction in total emitted power, directional body-induced fading, and polarization effects. The polar power patterns of the telemeter were measured for both isolated and in-situ cases, using horizontal and vertical polarization. The power patterns were numerically integrated to determine relative emitted power, and a reference dipole used to determine the emitted power for the isolated device. In isolation the telemeter radiation is vertically polarized and isotropic in nature. With the telemeter in-situ, total body absorption was found to be over 20 dB, with directional fades of up to 40 dB; there was extensive cross-polarization, with up to 60% of radiated power horizontally polarized. With limited radiated power and directional fading, the operating range for the telemeter is limited to single room operation (less than 10m). The majority of RF radiation is absorbed by the body, but the radiation hazard is negligible due to the low power level of the device. The high level of cross-polarization suggests that either horizontal or vertically polarized base-station antennas may be used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper gives an overview of the research done since 1999 at Eindhoven University of Technology in the Netherlands in the field of miniaturization of heterogeneous catalytic reactors. It is described that different incentives exist for the development of these microstructured reaction systems. These include the need for efficient research instruments in catalyst development and screening, the need for small-scale reactor devices for hydrogen production for low-power electricity generation with fuel cells, and the recent quest for intensified processing equipment and novel process architectures (as in the fine chemicals sector). It is demonstrated that also in microreaction engineering, catalytic engineering and reactor design go hand-in-hand. This is illustrated by the design of an integrated microreactor and heat-exchanger for optimum performance of a highly exothermic catalytic reaction, viz. ammonia oxidation. It is argued that future developments in catalytic microreaction technology will depend on the availability of very active catalysts (and catalyst coating techniques) for which microreactors may become the natural housing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background
Restorative justice is “a process whereby parties with a stake in a specific offence resolve collectively how to deal with the aftermath of the offence and its implications for the future” (Marshall 2003). Despite the increasing use of restorative justice programmes as an alternative to court proceedings, no systematic review has been undertaken of the available evidence on the effectiveness of these programmes with young offenders. Recidivism in young offenders is a particularly worrying problem, as recent surveys have indicated
the frequency of re-offences for young offenders has ranged from 40.2% in 2000 to 37.8% in 2007 (Ministry of Justice 2009)

Objectives
To evaluate the effects of restorative justice conferencing programmes for reducing recidivism in young offenders.

Search methods
We searched the following databases up to May 2012: CENTRAL, 2012 Issue 5, MEDLINE (1978 to current), Bibliography of Nordic Criminology (1999 to current), Index to Theses (1716 to current), PsycINFO (1887 to current), Social Sciences Citation Index (1970 to current), Sociological Abstracts (1952 to current), Social Care Online (1985 to current), Restorative Justice Online (1975 to current), Scopus (1823 to current), Science Direct (1823 to current), LILACS (1982 to current), ERIC (1966 to current), Restorative Justice Online (4May 2012),WorldCat (9May 2012), ClinicalTrials.gov (19May 2012) and ICTRP (19May 2012). ASSIA,National Criminal Justice Reference Service and Social Services Abstracts were searched up to May 2011. Relevant bibliographies, conference programmes and journals were also searched.

Selection criteria
Randomised controlled trials (RCTs) or quasi-RCTs of restorative justice conferencing versus management as usual, in young offenders.

Data collection and analysis
Two authors independently assessed the risk of bias of included trials and extracted the data. Where necessary, original investigators were contacted to obtain missing information.

Main results
Four trials including a total of 1447 young offenders were included in the review. Results failed to find a significant effect for restorative justice conferencing over normal court procedures for any of the main analyses, including number re-arrested (odds ratio (OR) 1.00, 95% confidence interval (CI) 0.59 to 1.71; P = 0.99), monthly rate of reoffending (standardised mean difference (SMD) -0.06, 95% CI -0.28 to 0.16; P = 0.61), young person’s remorse following conference (OR 1.73, 95% CI 0.97 to 3.10; P = 0.06), young person’s recognition of wrongdoing following conference (OR 1.97, 95% CI 0.81 to 4.80; P = 0.14), young person’s self-perception following conference (OR 0.95, 95% CI 0.55 to 1.63; P = 0.85), young person’s satisfaction following conference (OR 0.42, 95% CI 0.04 to 4.07; P = 0.45) and victim’s satisfaction following conference (OR 4.05, 95%CI 0.56 to 29.04; P = 0.16). A small number of sensitivity analyses did indicate significant effects, although all are to be interpreted with caution.

Authors’ conclusions
There is currently a lack of high quality evidence regarding the effectiveness of restorative justice conferencing for young offenders. Caution is urged in interpreting the results of this review considering the small number of included studies, subsequent low power and high risk of bias. The effects may potentially be more evident for victims than offenders. The need for further research in this area is highlighted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

True random number generation is crucial in hardware security applications. Proposed is a voltage-controlled true random number generator that is inherently field-programmable. This facilitates increased entropy as a randomness source because there is more than one configuration state which lends itself to more compact and low-power architectures. It is evaluated through electrical characterisation and statistically through industry-standard randomness tests. To the best of the author's knowledge, it is one of the most efficient designs to date with respect to hardware design metrics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissipative optomechanics studies the coupling of the motion of an optical element to the decay rate of a cavity. We propose and theoretically explore a realization of this system in the optical domain, using a combined Michelson-Sagnac interferometer, which enables a strong and tunable dissipative coupling. Quantum interference in such a setup results in the suppression of the lower motional sideband, leading to strongly enhanced cooling in the non-sideband-resolved regime. With state-of-the-art parameters, ground-state cooling and low-power quantum-limited position transduction are both possible. The possibility of a strong, tunable dissipative coupling opens up a new route towards observation of such fundamental optomechanical effects as nonlinear dynamics. Beyond optomechanics, the suggested method can be readily transferred to other setups involving nonlinear media, atomic ensembles, or single atoms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Details of a new low power fast Fourier transform (FFT) processor for use in digital television applications are presented. This has been fabricated using a 0.6-µm CMOS technology and can perform a 64 point complex forward or inverse FFT on real-time video at up to 18 Megasamples per second. It comprises 0.5 million transistors in a die area of 7.8 × 8 mm and dissipates 1 W. The chip design is based on a novel VLSI architecture which has been derived from a first principles factorization of the discrete Fourier transform (DFT) matrix and tailored to a direct silicon implementation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes how worst-case error analysis can be applied to solve some of the practical issues in the development and implementation of a low power, high performance radix-4 FFT chip for digital video applications. The chip has been fabricated using a 0.6 µm CMOS technology and can perform a 64 point complex forward or inverse FFT on real-time video at up to 18 Megasamples per second. It comprises 0.5 million transistors in a die area of 7.8×8 mm and dissipates 1 W, leading to a cost-effective silicon solution for high quality video processing applications. The analysis focuses on the effect that different radix-4 architectural configurations and finite wordlengths has on the FFT output dynamic range. These issues are addressed using both mathematical error models and through extensive simulation.