68 resultados para pin-on-disc wear test


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The flowfield around a supersonic projectile using a pin actuator control method has been predicted using computational fluid dynamics. It has been predicted using both viscous and inviscid methods for a number of positions. Both methods showed that an optimal longitudinal position exists. However, the inviscid model over-predicted the lateral acceleration due to the difference in shock formation around the pin between the two approaches. The optimal location was predicted independent of solver, however the higher-fidelity solver predicted lower achievable lateral accelerations. This is due to the viscous interactions caused by the pin. The effect of projectile orientation has shown that shielding the pin leads to reduced effectiveness due to the wake of the fin enveloping the pin. When the pin is exposed to onset flow, the forces achieved are increased. There is also an increase in the achievable forces and moments with increasing Mach number.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Massive young stellar objects (YSOs) are powerful infrared Hi line emitters. It has been suggested that these lines form in an outflow from a disc surrounding the YSO. Here, new two-dimensional Monte Carlo radiative transfer calculations are described which test this hypothesis. Infrared spectra are synthesized for a YSO disc wind model based on earlier hydrodynamical calculations. The model spectra are in qualitative agreement with the observed spectra from massive YSOs, and therefore provide support for a disc wind explanation for the Hi lines. However, there are some significant differences: the models tend to overpredict the Bra/Br? ratio of equivalent widths and produce line profiles which are slightly too broad and, in contrast to typical observations, are double-peaked. The interpretation of these differences within the context of the disc wind picture and suggestions for their resolution via modifications to the assumed disc and outflow structure are discussed. © 2005 RAS.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Although trait hope is thought to motivate goal-directed actions in the face of impediments, few studies have directly examined hope's role in overcoming obstacles, and none have done so while accounting for related goal constructs. We describe a study of 127 pediatric primary care providers who over the course of a year were asked to identify new cases of asthma and confirm previously diagnosed active disease by completing for each of their patients a brief survey validated for this purpose. These clinicians also completed measures of hope, self-efficacy, conscientiousness, and perceived obstacles to implementing a pediatric asthma management program. As predicted by hope theory, the agency component of hope buffered clinicians from perceived obstacles by facilitating the identification of asthma cases among high-hope clinicians in the face of obstacles. This buffering effect remained after controlling for self-efficacy and conscientiousness. We discuss the study findings in terms of current theories of goal-directed behavior and implications for delivering hope-related interventions, and we offer a testable hypothesis regarding when agency and pathways thinking facilitate goal-related behavior.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aims. To evaluate the effect of acute elevation of intraocular pressure (IOP) on optic disc cupping. Methods. 10 emmetropic and 10 myopic volunteers were included in this study. The cup area (CA) and cup volume (CV) of the optic disc were determined with the Heidelberg retina tomograph (HRT). After baseline determinations, a suction cup was used to increase the intraocular pressure (IOP) to 20-25 mmHg above the baseline and HRT images were obtained. Results. Baseline IOP was 13.5 (SD 1.3) mmHg and 12.6 (2.6) mmHg in the emmetropic and myopic groups, respectively. The IOP was elevated to 35.4 (3.3) mmHg and 34.4 (2.5) mmHg in the emmetropic and myopic groups, respectively. When compared with their baseline values, the cupping variables (CA and CV) were significantly increased (p <0.05) during the suction treatment in both emmetropic and myopic subjects. Conclusion. There was a significant enlargement in the optic disc cupping during the artificial increment of intraocular pressure in both emmetropic and myopic eyes. In non-glaucomatous eyes the optic nerve head has a partially dynamic topography dependent upon the level of IOP.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: This study was designed to evaluate the clinical agreement in the detection of optic disc changes and the ability of computerized image analysis to detect glaucomatous deterioration of the optic disc. Methods: Pairs of stereophotographs of 35 glaucomatous optic discs taken 5 years apart and of 5 glaucomatous discs photographed twice on the same day. Two glaucoma specialists examined the pairs of stereophotographs (35 cases and 5 controls) in a masked manner and judged whether the optic disc showed changes in the optic disc compatible with progression of glaucomatous damage. The stereophotographs of the five optic discs photographed twice on the same day (which by definition did not change) and of five cases judged to have deteriorated by both glaucoma specialists were analyzed by computerized image analysis with the Topcon ImageNet system. Intra- and inter-observer agreement in the detection of optic disc changes (evaluated using kappa statistic), and changes in the rim area to disc area ratio (evaluated using descriptive statistics and paired t-test). Results: Intra-observer agreement had a kappa value of 0.75 for observer 1 and 0.60 for the observer 2. Inter-observer agreement between the glaucoma specialists had a kappa value of 0.60. The image analyzer did not discriminate between controls and cases with clinically apparent glaucomatous change of the optic disc. Conclusion: Clinical agreement in detecting changes in the optic disc was moderate to substantial. Computerized image analysis with the Topcon ImageNet system appeared not to be useful in detecting glaucomatous changes of the optic disc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this paper is to investigate the mechanism of nanoscale fatigue using nano-impact and multiple-loading cycle nanoindentation tests, and compare it to previously reported findings of nanoscale fatigue using integrated stiffness and depth sensing approach. Two different film loading mechanism, loading history and indenter shapes are compared to comprehend the influence of test methodology on the nanoscale fatigue failure mechanisms of DLC film. An amorphous 100 nm thick DLC film was deposited on a 500 μm silicon substrate using sputtering of graphite target in pure argon atmosphere. Nano-impact and multiple-load cycle indentations were performed in the load range of 100 μN to 1000 μN and 0.1 mN to 100 mN, respectively. Both test types were conducted using conical and Berkovich indenters. Results indicate that for the case of conical indenter, the combination of nano-impact and multiple-loading cycle nanoindentation tests provide information on the life and failure mechanism of DLC film, which is comparable to the previously reported findings using the integrated stiffness and depth sensing approach. However, the comparison of results is sensitive to the applied load, loading mechanism, test-type and probe geometry. The loading mechanism and load history is therefore critical which also leads to two different definitions of film failure. The choice of exact test methodology, load and probe geometry should therefore be dictated by the in-service tribological conditions, and where necessary both test methodologies can be used to provide better insights of failure mechanism. Molecular dynamics (MD) simulations of the elastic response of nanoindentation is reported, which indicates that the elastic modulus of the film measured using MD simulation was higher than that experimentally measured. This difference is attributed to the factors related to the presence of material defects, crystal structure, residual stress, indenter geometry and loading/unloading rate differences between the MD and experimental results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this study, three different elastomers, namely hydrogenated nitrile butadiene rubber, fluoroelastomer and silicone, have been subjected to two different hard metallised coatings by ion implantation process. The three different elastomers are commonly used in various seal applications, where reduced wear and gas permeability are essential in maintaining seal performance and functionality. Samples of these rubbers have been coated with chromium coating in one set of tests. In the second set of tests, samples of elastomers have been coated with tungsten carbide coating being deposited on all the three different elastomers. Wear, gas permeability and mechanical behaviour of the coated samples were compared with each other and with the control uncoated elastomers. All the coated samples showed good reduction in gas permeability. With the use of metallised coatings, there has been improved resistance to wear in all the coated samples. Adhesion strength and effect of coating on the elastomer have been investigated by mechanical testing. Mechanical tests revealed good adhesion of metal coatings on all the rubber samples, and there was no detrimental effect on the mechanical properties after coating. © 2012 Institute of Materials, Minerals and Mining.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Some retrieved CoCrMo hip implants have shown that abrasive wear is one of the possible wear mechanisms invoked within such joints. To date, little work has focused on the third body abrasion of CoCrMo and therefore there is a general lack of understanding of the effect of abrasive size and volume concentration on the tribo-corrosion performance of the CoCrMo alloys. The present work assessed the tribo-corrosion behaviour of cast CoCrMo (F-75) under various abrasion-corrosion conditions by using a modified microabrasion tester incorporating a three-electrode electrochemical cell. The effects of reduced abrasive size/hardness and volume concentration, as well as the role of proteins on the tribo-corrosion performance of the cast CoCrMo alloy were addressed. The correlation between electrochemical and mechanical processes for different abrasion-corrosion test conditions has been discussed in detail. Results show that the reduction in abrasive size and volume concentration can significantly affect the abrasion-corrosion wear mechanisms and the wear-induced corrosion response of the material. The finding of this study implies that the smaller/softer third body particles generated in vivo could also result in significant wear-induced corrosion and therefore potential metal ion release, which could be potentially detrimental to both the patient health and the life span of the implants. © 2009 Elsevier Ltd. All rights reserved.