178 resultados para objective tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the experimental results of loading tests on two 18m span tapered member portal frames designed to BS 5950. Deflection test results for vertical, lateral and combined loading cases are compared with the predictions given by elastic analysis to BS 5950 and shown to be favourable. The predicted ultimate capacities and modes of failure, which were by lateral-torsional buckling of the columns, were also found to agree with the experimental behaviour. It was found that the method of modelling the tapered members as a series of prismatic elements gave good comparison with test results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To test the hypothesis that the self-perception of dental and facial attractiveness among patients requiring orthognathic surgery is no different from that of control patients.

Materials and Methods: Happiness with dental and facial appearance was assessed using questionnaires completed by 162 patients who required orthognathic treatment and 157 control subjects. Visual analog scale, binary, and open response data were collected. Analysis was carried out using a general linear model, logistic regression, and chi-square tests.

Results: Orthognathic patients were less happy with their dental appearance than were controls. Class II patients and women had lower happiness scores for their dental appearance. Among orthognathic patients, the "shape" and "prominence" of their teeth were the most frequent causes of concern. Older subjects, women, and orthognathic patients were less happy with their facial appearance. Class III orthognathic patients, older subjects, and women were more likely to have looked at their own face in profile. A greater proportion of Class II subjects than Class III subjects wished to change their appearance.

Conclusions: The hypothesis is rejected. The findings indicate that women and patients requiring orthognathic surgery had lower levels of happiness with their dentofacial appearance. Although Class II patients exhibited the lowest levels of happiness with their dental appearance, there was some evidence that concerns and awareness about their facial profile were more pronounced among the Class III patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this investigation Raman spectroscopy was shown to be a method that could be used to monitor the polymerisation of PMMA bone cement. Presently there is no objective method that orthopaedic surgeons can use to quantify the curing process of cement during surgery. Raman spectroscopy is a non-invasive, non-destructive technique that could offer such an option. Two commercially available bone cements (Palacos® R and SmartSet® HV) and different storage conditions (4 and 22°C) were used to validate the technique. Raman spectroscopy was found to be repeatable across all conditions with the completion of the polymerisation process particularly easy to establish. All tests were benchmarked against current temperature monitoring methods outlined in ISO and ASTM standards. There was found to be close agreement with the standard methods and the Raman spectroscopy used in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The LifeShirt is a novel ambulatory monitoring system that records cardio respiratory measurements outside the laboratory. Validity and reliability of cardiorespiratory measurements recorded by the LifeShirt were assessed and two methods of calibrating the LifeShirt were compared. Participants performed an incremental treadmill test and a constant work rate test (65% peak oxygen uptake) on four occasions (>48 In apart) and wore the LifeShirt, COSMED system and Polar Sport Tester simultaneously. The LifeShirt was calibrated using two methods: comparison to a spirometer; and 800 ml fixed-volume bag. Ventilation, respiratory rate, expiratory time and heart rate recorded by the LifeShirt were compared to measurements recorded by laboratory equipment. Sixteen adults participated (6M: 10F); mean (SD) age 23.1 (2.9) years. Agreement between the LifeShirt and laboratory equipment was acceptable. Agreement for ventilation was improved by calibrating the LifeShirt using a spirometer. Reliability was similar for the LifeShirt and the laboratory equipment. This study suggests that the LifeShirt provides a valid and reliable method of ambulatory monitoring. (C) 2009 Elsevier B.V. All rights reserved.