94 resultados para implant impression accuracy
The quality of reporting of diagnostic accuracy studies in glaucoma using scanning laser polarimetry
Resumo:
PURPOSE: Scanning laser polarimetry (SLP) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the SLP for diagnosing glaucoma. METHODS: A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the SLP for glaucoma was performed. Two reviewers independently selected and appraised the manuscripts. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS: A total of 47 papers were identified of which the first 10 (from 1997 to 2000) and the last 10 articles (from 2004 to 2005) were appraised. Interobserver rating agreement of STARD items was high (85.5% agreement, ?=0.796). The number of STARD items properly reported ranged from 3/25 to 19/25. Only a quarter of studies (5/20) explicitly reported more than half of the STARD items. Important aspects of the methodology were often missing such as participant sampling (reported in 40% of manuscripts), masking of the readers of the index test and reference standard (reported in 20% of manuscripts), and estimation of uncertainty (eg, 95% confidence intervals, reported in 25% of manuscripts). There was a slight increase in the number of STARD items reported with time. CONCLUSIONS: The quality of reporting of diagnostic accuracy tests for glaucoma with SLP is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies. © 2007 Lippincott Williams & Wilkins, Inc.
Resumo:
PURPOSE. To evaluate the diagnostic capability of tendency oriented perimetry (TOP) in glaucoma. METHODS. A): The diagnostic accuracy of mean defect (MD), square-root of the loss variance (sLV), and number of pathologic points (NPP) was calculated in 295 normal and 414 glaucoma eyes (179 early, 112 moderate, and 123 advanced) examined with TOP. B): Threshold fluctuation (F) and its relationship with the loss variance (LV) was measured in 34 normal and 33 glaucoma eyes (mean MD=3 dB; SD=3.9) for TOP and for full-threshold perimetry (FT). C): Twenty-eight eyes with stable glaucoma (mean MD=9.5 dB; SD=7.2) were examined six times to quantify LV error. D): TOP and FT were tested with the simulation program PeriSim using different behavior models. RESULTS. A): The best diagnostic index in early glaucoma (MD
Resumo:
PURPOSE. Scanning laser tomography with the Heidelberg retina tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the HRT for diagnosing glaucoma. METHODS. A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the HRT for glaucoma was performed. Two reviewers selected and appraised the papers independently. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS. A total of 29 articles were included. Interobserver rating agreement was observed in 83% of items (? = 0.76). The number of STARD items properly reported ranged from 5 to 18. Less than a third of studies (7/29) explicitly reported more than half of the STARD items. Descriptions of key aspects of the methodology were frequently missing. For example, the design of the study (prospective or retrospective) was reported in 6 of 29 studies, and details of participant sampling (e.g., consecutive or random selection) were described in 5 of 29 publications. The commonest description of diagnostic accuracy was sensitivity and specificity (25/29) followed by area under the ROC curve (13/29), with 9 of 29 publications reporting both. CONCLUSIONS. The quality of reporting of diagnostic accuracy tests for glaucoma with HRT is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies. Copyright © Association for Research in Vision and Ophthalmology.
Resumo:
Aim: To evaluate the quality of reporting of all diagnostic studies published in five major ophthalmic journals in the year 2002 using the Standards for Reporting of Diagnostic Accuracy (STARD) initiative parameters. Methods: Manual searching was used to identify diagnostic studies published in 2002 in five leading ophthalmic journals, the American Journal of Ophthalmology (AJO), Archives of Ophthalmology (Archives), British Journal of Ophthalmology (BJO), Investigative Ophthalmology and Visual Science (IOVS), and Ophthalmology. The STARD checklist of 25 items and flow chart was used to evaluate the quality of each publication. Results: A total of 16 publications were included (AJO = 5, Archives = 1, BJO = 2, IOVS = 2, and Ophthalmology = 6). More than half of the studies (n = 9) were related to glaucoma diagnosis. Other specialties included retina (n = 4) cornea (n = 2), and neuro-ophthalmology (n = 1). The most common description of diagnostic accuracy was sensitivity and specificity values, published in 13 articles. The number of fully reported items in evaluated studies ranged from eight to 19. Seven studies reported more than 50% of the STARD items. Conclusions: The current standards of reporting of diagnostic accuracy tests are highly variable. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies.
Resumo:
Aim: To compare the diagnostic performance of accredited glaucoma optometrists (AGO) for both the diagnosis of glaucoma and the decision to treat with that of routine hospital eye care, against a reference standard of expert opinion (a consultant ophthalmologist with a special interest in glaucoma). Methods: A directly comparative, masked, performance study was undertaken in Grampian, Scotland. Of 165 people invited to participate, 100 (61%) were examined. People suspected of having glaucoma underwent, within one month, a full ophthalmic assessment in both a newly established community optometry led glaucoma management scheme and a consultant led hospital eye service. Results: Agreement between the AGO and the consultant ophthalmologist in diagnosing glaucoma was substantial (89%; ? = 0.703, SE = 0.083). Agreement over the need for treatment was also substantial (88%; ? = 0.716, SE = 0.076). The agreement between the trainee ophthalmologists and the consultant ophthalmologist in the diagnosis of glaucoma and treatment recommendation was moderate (83%, ? = 0.541, SE = 0.098, SE = 0.98; and 81%, ? = 0.553, SE = 0.90, respectively). The diagnostic accuracy of the optometrists in detecting glaucoma in this population was high for specificity (0.93 (95% confidence interval, 0.85 to 0.97)) but lower for sensitivity (0.76 (0.57 to 0.89)). Performance was similar when accuracy was assessed for treatment recommendation (sensitivity 0.73 (0.57 to 0.85); specificity 0.96 (0.88 to 0.99)). The differences in sensitivity and specificity between AGO and junior ophthalmologist were not statistically significant. Conclusions: Community optometrists trained in glaucoma provided satisfactory decisions regarding diagnosis and initiation of treatment for glaucoma. With such additional training in glaucoma, optometrists are at least as accurate as junior ophthalmologists but some cases of glaucoma are missed.
Resumo:
Objective: To evaluate the quality of reporting of diagnostic accuracy studies using optical coherence tomography (OCT) in glaucoma. Design: Descriptive series of published studies. Participants: Published studies reporting a measure of the diagnostic accuracy of OCT for glaucoma. Methods: Review of English language papers reporting measures of diagnostic accuracy of OCT for glaucoma. Papers were identified from a Medline literature search performed in June 2006. Articles were appraised using the 25 items provided by the Standards for Reporting of Diagnostic Accuracy (STARD) initiative. Each item was recorded as full, partially, or not reported. Main Outcome Measures: Degree of compliance with the STARD guidelines. Results: Thirty papers were appraised. Eight papers (26.7%) fully reported more than half of the STARD items. The lowest number of fully reported items in a study was 5 and the highest was 17. Descriptions of key aspects of methodology frequently were missing. For example, details of participant sampling (e.g., consecutive or random selection) were described in only 8 (26.7%) of 30 publications. Measures of statistical uncertainty were reported in 18 (60%) of 30 publications. No single STARD item was fully reported by all the papers. Conclusions: The standard of reporting of diagnostic accuracy studies in glaucoma using OCT was suboptimal. It is hoped that adoption of the STARD guidelines will lead to an improvement in reporting of diagnostic accuracy studies, enabling clearer evidence to be produced for the usefulness of OCT for the diagnosis of glaucoma. © 2007 American Academy of Ophthalmology.
Resumo:
Aim: To assess the sample sizes used in studies on diagnostic accuracy in ophthalmology. Design and sources: A survey literature published in 2005. Methods: The frequency of reporting calculations of sample sizes and the samples' sizes were extracted from the published literature. A manual search of five leading clinical journals in ophthalmology with the highest impact (Investigative Ophthalmology and Visual Science, Ophthalmology, Archives of Ophthalmology, American Journal of Ophthalmology and British Journal of Ophthalmology) was conducted by two independent investigators. Results: A total of 1698 articles were identified, of which 40 studies were on diagnostic accuracy. One study reported that sample size was calculated before initiating the study. Another study reported consideration of sample size without calculation. The mean (SD) sample size of all diagnostic studies was 172.6 (218.9). The median prevalence of the target condition was 50.5%. Conclusion: Only a few studies consider sample size in their methods. Inadequate sample sizes in diagnostic accuracy studies may result in misleading estimates of test accuracy. An improvement over the current standards on the design and reporting of diagnostic studies is warranted.
Resumo:
Porous titanium samples were manufactured using the 3D printing and sintering method in order to determine the effects of final sintering temperature on morphology and mechanical properties. Cylindrical samples were printed and split into groups according to a final sintering temperature (FST). Irregular geometry samples were also printed and split into groups according to their FST. The cylindrical samples were used to determine part shrinkage, in compressive tests to provide stress-strain data, in microCT scans to provide internal morphology data and for optical microscopy to determine surface morphology. All of the samples were used in microhardness testing to establish the hardness. Below 1100 C FST, shrinkage was in the region of 20% but increased to approximately 30% by a FST of 1300 C. Porosity varied from a maximum of approximately 65% at the surface to the region of 30% internally. Between 97 and 99% of the internal porosity is interconnected. Average pore size varied between 24 µm at the surface and 19 µm internally. Sample hardness increased to in excess of 300 HV0.05 with increasing FST while samples with an FST of below 1250 C produced an elastic-brittle stress/strain curve and samples above this displayed elastic-plastic behaviour. Yield strength increased significantly through the range of sintering temperatures while the Young's modulus remained fairly consistent. © 2013 Elsevier B.V.
Resumo:
OBJECTIVE:
This study aimed to investigate antimicrobial treatment of an infected cochlear implant, undertaken in an attempt to salvage the infected device.
METHODS:
We used the broth microdilution method to assess the susceptibility of meticillin-sensitive Staphylococcus aureus isolate, cultured from an infected cochlear implant, to common antimicrobial agents as well as to novel agents such as tea tree oil. To better simulate in vivo conditions, where bacteria grow as microcolonies encased in glycocalyx, the bactericidal activity of selected antimicrobial agents against the isolate growing in biofilm were also compared.
RESULTS:
When grown planktonically, the S aureus isolate was susceptible to 17 of the 18 antimicrobials tested. However, when grown in biofilm, it was resistant to all conventional antimicrobials. In contrast, 5 per cent tea tree oil completely eradicated the biofilm following exposure for 1 hour.
CONCLUSION:
Treatment of infected cochlear implants with novel agents such as tea tree oil could significantly improve salvage outcome.
Resumo:
Purpose: The dose delivery accuracy of 30 clinical step and shoot intensity modulated radiation therapy plans was investigated using the single integrated multileaf collimator controller of the Varian Truebeam linear accelerator (linac) (Varian Medical Systems, Palo Alto, CA) and compared with the dose delivery accuracy on a previous generation Varian 2100CD C-Series linac.
Methods and Materials: Ten prostate, 10 prostate and pelvic node, and 10 head-and-neck cases were investigated in this study. Dose delivery accuracy on each linac was assessed using Farmer ionization chamber point dose measurements, 2-dimensional planar ionization chamber array measurements, and the corresponding Varian dynamic log files. Absolute point dose measurements, fluence delivery accuracy, leaf position accuracy, and the overshoot effect were assessed for each plan.
Results: Absolute point dose delivery accuracy increased by 1.5% on the Truebeam compared with the 2100CD linac. No improvement in fluence delivery accuracy between the linacs, at a gamma criterion of 3%/3 mm was measured using the 2-dimensional ionization chamber array, with median (interquartile range) gamma passing rates of 98.99% (97.70%-99.72%) and 99.28% (98.26%-99.75%) for the Truebeam and 2100CD linacs, respectively. Varian log files also showed no improvement in fluence delivery between the linacs at 3%/3 mm, with median gamma passing rates of 99.97% (99.93%-99.99%) and 99.98% (99.94%-100%) for the Truebeam and 2100CD linacs, respectively. However, log files revealed improved leaf position accuracy and fluence delivery at 1%/1 mm criterion on the Truebeam (99.87%; 99.78%-99.94%) compared with the 2100CD linac (97.87%; 91.93%-99.49%). The overshoot effect, characterized on the 2100CD linac, was not observed on the Truebeam.
Conclusions: The integrated multileaf collimator controller on the Varian Truebeam improves clinical treatment delivery accuracy of step and shoot intensity modulated radiation therapy fields compared with delivery on a Varian C-series linac. © 2014.
Resumo:
OBJECTIVE:
"Blind" shoulder injections are often inaccurate and infiltrate untargeted structures. We tested a hypothesis that optimizing certain anatomical and positional factors would improve accuracy and reduce dispersal.
METHODS:
We evaluated one subacromial and one glenohumeral injection technique on cadavers.
RESULTS:
Mean accuracy was 91% for subacromial-targeted and 74 and 91% (worst- and best-case scenarios) for joint-targeted injections. Mean dispersal was 19% for subacromial-targeted and 16% for joint-targeted injections. All results bettered those reported previously.
CONCLUSION:
These "optimized" techniques might improve accuracy and limit dispersal of blind shoulder injections in clinical situations, benefiting efficacy and safety. However, evaluation is required in a clinical setting.