145 resultados para electrochemical biosensor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid analytical optical biosensor-based immunoassay was developed and validated for the detection of okadaic acid (OA) and its structurally related toxins from shellfish matrix. The assay utilizes a monoclonal antibody which binds to the OA group of toxins in order of their toxicities, resulting in a pseudofunctional assay. Single-laboratory validation of the assay for quantitative detection of OA determined that it has an action limit of 120 mu g/kg, a limit of detection of 31 mu g/kg, and a working range of 31-174 mu g/kg. The midpoint on the standard matrix calibration curve is 80 mu g/kg, half the current regulatory limit. Inter- and intra-assay studies of negative mussel samples spiked with various OA concentrations produced average coefficient of variation (CV) and standard deviation (SD) values of 7.9 and 10.1, respectively. The assay was also validated to confirm the ability to accurately codetect and quantify dinophysistoxin-1 (DTX-1), DTX-2, and DTX-3 from shellfish matrix. Alkaline hydrolysis was not required for the detection of DTX-3 from matrix. Excellent correlations with the data generated by the biosensor method and liquid chromatography/tandem mass spectrometry (LC/MS/MS) were obtained using a certified reference material (R-2 = 0.99), laboratory reference material, and naturally contaminated mussel samples (R-2 = 0.97). This new procedure could be used as a rapid screening procedure replacing animal-based tests for DSP toxins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical oxidation of catechol and dopamine has been studied at a platinum micro-electrode (10 pm diameter) in two room temperature ionic liquids (RTILs): 1-Ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([C(2)mim][NTf2]) and 1-Butyl-3-methylimidazolium tetrafluoroborate ([C(4)mim][BE4]). For catechol in [C(2)mim][NTf2], an electrochemically quasi-reversible oxidation peak was observed at 1.1 V vs. Pt with a back peak at 0.4 V vs. Pt. This is assigned to the two-electron oxidation of catechol to doubly protonated o-benzoquinone. Double-step chronoamperometry gave a diffusion coefficient for the catechol and the oxidised species which is 3.8 x 10(-11) m(2) s(-1) for both. For catechol in [C(4)mim][BF4], a two-electron oxidation wave was observed at 1.0 V vs. Pt with no back peak. Another peak at less positive potential was also observed at 0.6 V vs. Pt in [C(4)mim][BF4] but not in [C(2)mim][NTf2] which is assigned to the adsorption of electrochemically formed neutral o-benzoquinone on the platinum electrode. The oxidised protonated o-benzoquinone is suggested to be deprotonated by the [BF4](-) anion, but not by the [NTf2](-) anion: hence adsorption of the neutral species at the platinum electrode, not the charged species. For dopamine in both RTILs, two chemically irreversible oxidation peaks were observed at 0.75 V and 1.1 V vs. Pt, and assigned to the oxidation of dopamine to the corresponding semi-quinone and the quinone. Potential-step chronoamperometry was carried out on the oxidation waves of dopamine in [C(2)mim][NTf2] and the diffusion coefficient of species in solution was calculated to be 6.85 x 10(-12) m(2) s(-1) and confirmed that the waves corresponded to one and two electron processes. A third wave was observed at 1.8 V vs. Pt which is attributed to the oxidation of the amine group to a radical cation with likely subsequent follow up chemistry. In [C(4)mim][BF4] a peak at less positive potential was observed for dopamine, similar to catechol which is assigned to the adsorption of the neutral quinone species on the platinum electrode formed by the reaction of the removal of protons from the oxidised dopamine with the [BF4](-) anion. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical reduction of the disperse azo dyes Red1, Red13 and Orange1 (Or1) was investigated in the RTILs [C(4)mim][NTf2] and [C(4)mpyrr][NTf2], and in contrast with their behavior in conventional aprotic solvents, was shown to proceed via a reversible one electron step to form stable radical anion, which is further reduced at more negative potentials to the dianion. In [C(4)mpyrr][NTf2], cleavage of the N-H bond on the secondary amine was inferred for Orange1, and the ease at which this cleavage occurred is rationalized in terms of acidity of the amine moiety. The ease of reduction was observed to decrease in the order Or1 > Red13 > Red1, and is related to the electron delocalization within the molecule and the electron withdrawing power of the substituents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reduction of guanine was studied by microelectrode voltammetry in the room temperature ionic liquids (RTILs) N-hexyltriethylammonium his (trifluoromethanesulfonyl) imide [N-6.2.2.2][N(Tf)(2)], 1-butyl-3-methylimidazolium hexafluorosphosphate [C(4)mim] [PF6], N-butyl-N-methyl-pyrrolidinium bis(trifluoromethanesulfonyl)imide [C(4)mpyrr][N(Tf)(2)], 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide [C-4mim][N(TF)(2)], N-butyl-N-methyl-pyrrolidinium dicyanamide [C(4)mpyrr][N(NC)(2)] and tris(P-hexyl)-tetradecylphosphonium trifluorotris(pentafluoroethyl)phosphate [P-14,P-6,(6,6)][FAP] on a platinum microelectrode. In [N-6,N-2,N-2,N-2][NTf2] and [P-14,P-6,P-6.6][FAP], but not in the other ionic liquids studied, guanine reduction involves a one-electron, diffusion-controlled process at very negative potential to produce an unstable radical anion. which is thought to undergo a dimerization reaction, probably after proton abstraction from the cation of the ionic liquid. The rate of this subsequent reaction depends on the nature of the ionic liquid, and it is faster in the ionic liquid [P-14,P-6,P-6.6[FAP], in which the formation of the resulting dimer can be voltammetrically monitored at less negative potentials than required for the reduction of the parent molecule. Adenine showed similar behaviour to guanine but the pyrimidines thymine and cytosine did not; thymine was not reduced at potentials less negative than required for solvent (RTIL) decomposition while only a poorly defined wave was seen for cytosine. The possibility for proton abstraction from the cation in [N-6,N-2,N-2,N-2],[NTF2] and [P-14,P-6,P-6.6][FAP] is noted and this is thought to aid the electrochemical dimerization process. The resulting rapid reaction is thought to shift the reduction potentials for guanine and adenine to lower values than observed in RTILs where the scope for proton abstraction is not present. Such shifts are characteristic of so-called EC processes where reversible electron transfer is followed by a chemical reaction. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A research element of the European Union (EU) sixth Framework project BioCop focused on the development of a surface plasmon resonance (SPR) biosensor assay for the detection of paralytic shellfish poisoning (PSP) toxins in shellfish as an alternative to the increasingly ethically unacceptable mouse bioassay. A biosensor assay was developed using both a saxitoxin binding protein and chip surface in tandem with a highly efficient simple extraction procedure. The present report describes the single laboratory validation of this immunological screening method, for this complex group of toxins with differing toxicities, according to the European Decision 2002/657/EC in conjunction with IUPAC and AOAC single laboratory validation guidelines. The different performance characteristics (detection capability CC beta, specificity/selectivity, repeatability, reproducibility, stability, and applicability) were determined in relation to the EU regulatory limit of 800 mu g of saxitoxin equivalents (STX eq) per kg of shellfish meat. The detection capability CC beta was calculated to be 120 mu g/kg. Intra-assay repeatability was found to be between 2.5 and 12.3% and interassay reproducibility was between 6.1 and 15.2% for different shellfish matrices. Natural samples were also evaluated and the resultant data displayed overall agreements of 96 and 92% with that of the existing AOAC approved methods of mouse bioassay (MBA) and high performance liquid chromatography (HPLC), respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reliable and cost-effective electrochemical method for the detection of deoxynivalenol (DON) in cereals and cereal-based food samples based on the use of a novel anti-DON Fab fragment is presented. The analytical system employed, Enzyme-Linked-Immunomagnetic-Electrochemical (ELIME) assay, is based on the use of immunomagnetic beads (IMBs) coupled with eight magnetized screen-printed electrodes (8-mScPEs) as electrochemical transducers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tiamulin (TIA) is an antimicrobial veterinary drug administered subtherapeutically to prevent swine dysentery and pneumonia. Due to its stability, crystalline structure, and water-soluble properties, TIA is a prime candidate for environmental monitoring. However, there are currently no screening methods available for TIA in environmental matrices, such as grass or ground water. In this paper, the development and validation of a screening method using optical SPR biosensor technology is presented. A solvent extraction was carried out on samples prior to analysis using the Biacore Q instrument. The limit of detection for the assay in grass and ground water was 10.8 ng/g and 2.4 ng/ml, respectively. In addition, the assay was shown to be of an acceptable standard with regard to both accuracy and reproducibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ractopamine (RCT) is a member of the beta-2-agonist (beta-agonist) family. It is licensed for use as an animal growth promoter in more than 20 countries worldwide, including the United States and Canada, but is either not licensed or prohibited by over 150 others, including those within the European Union. The issue of the use of RCT in livestock bound for human consumption has risen to prominence recently following the decision by The People's Republic of China to ban the import of pork from a number of processing plants after finding traces of RCT in shipments from the U.S.A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paralytic shellfish poisoning (PSP) toxin monitoring in shellfish is currently performed using the internationally accredited AOAC mouse bioassay. Due to ethical and performance-related issues associated with this bioassay, the European Commission has recently published directives extending procedures that may be used for official PSP control. The feasibility of using a surface plasmon resonance optical biosensor to detect PSP toxins in shellfish tissue below regulatory levels was examined. Three different PSP toxin protein binders were investigated: a sodium channel receptor (SCR) preparation derived from rat brains, a monoclonal antibody (GT13-A) raised to gonyautoxin 2/3, and a rabbit polyclonal antibody (R895) raised to saxitoxin (STX). Inhibition assay formats were used throughout. Immobilization of STX to the biosensor chip surface was achieved via amino-coupling. Specific binding and inhibition of binding to this surface was achieved using all proteins tested. For STX calibration curves, 0 - 1000 ng/mL, IC50 values for each binder were as follows: SCR 8.11 ng/mL; GT13-A 5.77 ng/mL; and R895 1.56 ng/mL. Each binder demonstrated a different cross-reactivity profile against a range of STX analogues. R895 delivered a profile that was most likely to detect the widest range of PSP toxins at or below the internationally adopted regulatory limits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Growth-promoting agents are illicitly used during animal rearing processes and the detection of their use is limited by new compounds and dosing practices that limit the efficiency of current testing which is based on residue analysis by liquid chromatography–tandem mass spectrometry (LC–MS/MS) and gas chromatography–mass spectrometry (GC–MS) methodology. An alternative approach is to use indirect biological evidence as a screening tool to identify growth-promoter treated animals thus improving the effectiveness of residue testing through the targeted sampling of these animals. Sex hormone-binding globulin (SHBG) is a glycoprotein which binds and controls the levels of sex-hormones within the circulation. Using a biosensor assay based on measurement of binding to an immobilised 1a-dihydrotestosterone (1a-DHT) derivative, reduced SHBG binding capacities were detected in growth-promoter treated animals. During the course of a veal treatment regime based on repeated oestradiol benzoate, nortestosterone decanoate and dexamethasone administrations, treated male and female calves were shown to have significantly lower SHBG capacities. To assess the effectiveness of using SHBG binding capacities as a biomarker of treatment and to investigate the role of individual growth-promoter components to the SHBG capacity lowering effects, adult heifer animals were subjected to repeated doses of nortestosterone decanoate. These animals also demonstrated a reduction in SHBG capacity levels at Day 39 of the study, in contrast to oestradiol benzoate treated adult steers who were found to have unaltered levels. These findings suggest that the measurement of SHBG binding capacities using a biosensor assay has potential in the identification of illegally treated animals, particularly those exposed to androgens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enzyme labeled immunosorbent assay (ELISA) and surface plasmon resonance (SPR) biosensor assay for the detection of paralytic shellfish poisoning (PSP) toxins were developed and a comparative evaluation was performed. A polyclonal antibody (BC67) used in both assay formats was raised to saxitoxin–jeffamine–BSA in New Zealand white rabbits. Each assay format was designed as an inhibition assay. Shellfish samples (n = 54) were evaluated by each method using two simple rapid extraction procedures and compared to the AOAC high performance liquid chromatography (HPLC) and the mouse bioassay (MBA). The results of each assay format were comparable with the HPLC and MBA methods and demonstrate that an antibody with high sensitivity and broad specificity to PSP toxins can be applied to different immunological techniques. The method of choice will depend on the end-users needs. The reduced manual labor and simplicity of operation of the SPR biosensor compared to ELISA, ease of sample extraction and superior real time semi-quantitative analysis are key features that could make this technology applicable in a high-throughput monitoring unit.