124 resultados para bovine viral diarrhea
Resumo:
Surface plasmon resonance (SPR) based biosensor technology has been widely used in life science research for many applications. While the advantages of speed, ruggedness, versatility, sensitivity and reproducibility are often quoted, many researchers have experienced severe problem of non-specific binding (NSB) to chip surfaces when performing analysis of biological samples Such as bovine serum. Using the direct measurement of the bovine protein leptin, present in bovine serum samples as a model, a unique buffering system has been developed and optimised which was able to significantly reduce the non-specific interactions of bovine serum components with the carboxymethyl dextran chip (CM5) surface on a Biacore SPR The developed NSB buffering system comprised of HBS-EP buffer, containing 0.5 M NaCl, 0.005% CM-dextran pH 9.0. An average NSB reduction (n = 20) of 85.9% and 87.3% was found on an unmodified CM5 surface and a CM5 with bovine leptin immobilised on the chip surface, respectively. A reduction in NSB of up to 94% was observed on both surfaces. The concentration of the constitutive components and pH of the buffer were crucial in achieving this outcome. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
The illegal use of anabolic substances in the meat producing industry is an ongoing problem due to the continual production of new synthetic compounds and/or the practice of low-level cocktail administration to avoid detection by the surveillance schemes of EU member states National Plan surveillance systems.
We present a highly sensitive reporter gene assay and sample extraction procedure based on a two step solid phase extraction and high performance liquid chromatography, developed for the detection of glucocorticoid abuse in bovine urine. The assay is capable of detecting compounds with glucocorticoid bioactivity and is extremely sensitive with an EC50 of 0.79 ng mL-1 for dexamethasone. New or unknown compounds with glucocorticoid bioactivity and low-level cocktail mixtures are detectable by this assay.
Cross-reactivity data for a range of 11ß-hydroxyglucocorticoids has been provided. This assay shows low interference from the 11-keto prohormones and other steroidal hormones. The assay may be suitable for application in other matrices such as hair. In conclusion this screening assay offers advantages over existing analytical techniques.
Resumo:
The objective of this study was to evaluate the effects of antimicrobial drug use, gastric acid-suppressive agent use, and infection control practices on the incidence of Clostridium difficile-associated diarrhea (CDAD) in a 426-bed general teaching hospital in Northern Ireland. The study was retrospective and ecological in design. A multivariate autoregressive integrated moving average (time-series analysis) model was built to relate CDAD incidence with antibiotic use, gastric acid-suppressive agent use, and infection control practices within the hospital over a 5-year period (February 2002 to March 2007). The findings of this study showed that temporal variation in CDAD incidence followed temporal variations in expanded-spectrum cephalosporin use (average delay = 2 months; variation of CDAD incidence = 0.01/100 bed-days), broad-spectrum cephalosporin use (average delay = 2 months; variation of CDAD incidence = 0.02/100 bed-days), fluoroquinolone use (average delay = 3 months; variation of CDAD incidence = 0.004/100 bed-days), amoxicillin-clavulanic acid use (average delay = 1 month; variation of CDAD incidence = 0.002/100 bed-days), and macrolide use (average delay = 5 months; variation of CDAD incidence = 0.002/100 bed-days). Temporal relationships were also observed between CDAD incidence and use of histamine-2 receptor antagonists (H2RAs; average delay = 1 month; variation of CDAD incidence = 0.001/100 bed-days). The model explained 78% of the variance in the monthly incidence of CDAD. The findings of this study highlight a temporal relationship between certain classes of antibiotics, H2RAs, and CDAD incidence. The results of this research can help hospitals to set priorities for restricting the use of specific antibiotic classes, based on the size-effect of each class and the delay necessary to observe an effect.
Resumo:
Aim: The aim of this study was to determine if asthmatic children have viruses more commonly detected in lower airways during asymptomatic periods than normal children. Methods: Fifty-five asymptomatic children attending elective surgical procedures (14 with stable asthma, 41 normal controls) underwent non-bronchoscopic bronchoalveolar lavage. Differential cell count and PCR for 13 common viruses were performed. Results: Nineteen (35%) children were positive for at least one virus, with adenovirus being most common. No differences in the proportion of viruses detected were seen between asthmatic and normal ‘control’ children. Viruses other than adenovirus were associated with higher neutrophil counts, suggesting that they caused an inflammatory response in both asthmatics and controls (median BAL neutrophil count, 6.9% for virus detected vs. 1.5% for virus not detected, p = 0.03). Conclusions: Over one-third of asymptomatic children have a detectable virus (most commonly adenovirus) in the lower airway; however, this was not more common in asthmatics. Viruses other than adenovirus were associated with elevated neutrophils suggesting that viral infection can be present during relatively asymptomatic periods in asthmatic children.
Resumo:
A rapid liquid chromatographic-tandem mass spectrometric (LC-MS/MS) multi-residue method for the simultaneous quantitation and identification of sixteen synthetic growth promoters and bisphenol A in bovine milk has been developed and validated. Sample preparation was straightforward, efficient and economically advantageous. Milk was extracted with acetonitrile followed by phase separation with NaCl. After centrifugation, the extract was purified by dispersive solid-phase extraction with C18 sorbent material. The compounds were analysed by reversed-phase LC-MS/MS using both positive and negative ionization and operated in multiple reaction monitoring (MRM) mode, acquiring two diagnostic product ions from each of the chosen precursor ions for unambiguous confirmation. Total chromatographic run time was less than 10 min for each sample. The method was validated at a level of 1 mu g L-1. A wide variety of deuterated internal standards were used to improve method performance. The accuracy and precision of the method were satisfactory for all analytes. The confirmative quantitative liquid chromatographic tandem mass spectrometric (LC-MS/MS) method was validated according to Commission Decision 2002/657/EC. The decision limit (CC alpha) and the detection capability (CC beta) were found to be below the chosen validation level of 1 mu g L-1 for all compounds. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
There is a need to provide rapid, sensitive, and often high throughput detection of pathogens in diagnostic virology. Viral gastroenteritis is a serious health issue often leading to hospitalization in the young, the immunocompromised and the elderly. The common causes of viral gastroenteritis include rotavirus, norovirus (genogroups I and II), astrovirus, and group F adenoviruses (serotypes 40 and 41). This article describes the work-up of two internally controlled multiplex, probe-based PCR assays and reports on the clinical validation over a 3-year period, March 2007 to February 2010. Multiplex assays were developed using a combination of TaqMan™ and minor groove binder (MGB™) hydrolysis probes. The assays were validated using a panel of 137 specimens, previously positive via a nested gel-based assay. The assays had improved sensitivity for adenovirus, rotavirus, and norovirus (97.3% vs. 86.1%, 100% vs. 87.8%, and 95.1% vs. 79.5%, respectively) and also more specific for targets adenovirus, rotavirus, and norovirus (99% vs. 95.2%, 100% vs. 93.6%, and 97.9% vs. 92.3%, respectively). For the specimens tested, both assays had equal sensitivity and specificity for astrovirus (100%). Overall the probe-based assays detected 16 more positive specimens than the nested gel-based assay. Post-introduction to the routine diagnostic service, a total of 9,846 specimens were processed with multiplex 1 and 2 (7,053 pediatric, 2,793 adult) over the 3-year study period. This clinically validated, probe-based multiplex testing algorithm allows highly sensitive and timely diagnosis of the four most prominent causes of viral gastroenteritis.