139 resultados para Zasius, Ulrich, 1461-1536
Resumo:
This paper outlines the use of phasor measurement unit (PMU) records to validate models of fixed speed induction generator (FSIG)-based wind farms during frequency transients. Wind turbine manufacturers usually create their own proprietary models which they can supply to power system utilities for stability studies, subject to confidentiality agreements. However, it is desirable to confirm the accuracy of supplied models with measurements from the particular installation, in order to assess their validity under real field conditions. This is prudent due to possible changes in control algorithms and design retrofits, not accurately reflected or omitted in the supplied model. One important aspect of such models, especially for smaller power systems with limited inertia, is their accuracy during system frequency transients. This paper, therefore, assesses the accuracy of FSIG models with regard to frequency stability, and hence validates a subset of the model dynamics. Such models can then be used with confidence to assess wider system stability implications. The measured and simulated response of a wind farm using doubly fed induction generator (DFIG) technology is also assessed.
Resumo:
Assessment of elevated concentrations of potentially toxic elements (PTE) in soils and the association with specific soil parent material have been the focus of research for a number of years. Risk-based assessment of potential exposure scenarios to identified elevated PTE concentrations has led to the derivation of site- and contaminant-specific soil guideline values (SGVs), which represent generic assessment criteria (GACs) to identify exceeded levels that may reflect an unacceptable risk to human health. A better understanding of the ‘bioavailable’ or ‘bioaccessible’ contaminant concentrations offers an opportunity to better refine contaminant exposure assessments. Utilizing a comprehensive soil geochemical dataset for Northern Ireland provided by the Tellus Survey (GSNI) in conjunction with supplementary bioaccessibility testing of selected soil samples following the Unified BARGE Method, this paper uses exploratory data analysis and geostatistical analysis to investigate the spatial variability of pseudo-total and bioaccessible concentrations of As, Cd, Co, Cr. Cu, Ni, Pb, U, V and Zn. The paper investigates variations in individual element concentrations as well as cross-element correlations and observed lithological/pedological associations. The analysis of PTE concentrations highlighted exceeded levels of GAC values for V and Cr and exceeded SGV/GAC values for Cd, Cu, Ni, Pb, and Zn. UBM testing showed that for some soil parent materials associated with elevated PTE concentrations e.g. the Antrim Lava Group with high Ni concentrations, the measured oral bioaccessible fraction was relatively low. For other soil parent materials with relatively moderate PTE concentrations, measured oral bioaccessible fraction was relatively high (e.g. the Gala Sandstone Group of the Southern Uplands-Down Longford Terrain). These findings have implications for regional human health risk assessments for specific PTEs.
Resumo:
The performance optimisation of automotive catalysts has been the focus of a great deal of research for many years as the automotive industry has endeavored to reduce the emission of toxic and pollutant gases generated from internal combustion engines. Just as the emissions from diesel and gasoline combustion vary so do the emissions from combustion of alternative fuels such as ethanol; the variation is in both quantity and chemical composition. In particular, when ethanol is contained in the fuel, ethanol and acetaldehyde are present in the exhaust gas stream and these are two compounds which the catalytic converter has not traditionally been designed to manage. The aim of the study outlined in this paper was to assess the performance of various catalyst formulations when subjected to a representative ethanol exhaust gas mixture. Three automotive catalytic converter formulations were tested including a fully Pt sample, a PdRh three-way catalyst sample and a fully Pd sample. Initially the samples were tested using single component hydrocarbon light-off tests followed by a set of tests with carbon monoxide included as an inlet gas to observe its effect on each individual hydrocarbon oxidation. Finally, each formulation was tested using a full E85 exhaust gas mixture. The study was carried out using a synthetic gas reactor along with FTIR and FID exhaust gas analysers. All formulations showed selectivity toward acetaldehyde formation from ethanol dehydrogenation which resulted in negative acetaldehyde conversion across each of the samples during the mixture tests. The fully Pt sample was the most detrimentally affected by the introduction of carbon monoxide into the gas feed. The Pd and PdRh samples exhibited a tendency toward acetaldehyde decomposition resulting in methane and carbon monoxide formation. The Pt sample did not form methane but did form ethylene as a result of ethanol dehydration.
Resumo:
The diffusion-controlled response and recovery behaviour of a naked optical film sensor (i.e., with no protective membrane) with a hyperbolic-type response [i.e., S0/S = (1 + Kc), where S is the measured value of the absorbance or luminescence intensity of one form of the sensor dye in the presence of the analyte, S0 is the observed value of S in the absence of analyte and K is a constant] to changes in analyte concentration, c, in a system under test is approximated using a simple model, and described more accurately using a numerical model; in both models it is assumed that the system under test represents an infinite reservoir. Each model predicts the variations in the response and recovery times of such an optical sensor, as a function of the final external analyte concentration, the film thickness (I) and the analyte diffusion coefficient (D). From an observed signal versus time profile for a naked optical film sensor it is shown how values for K and D/I2 can be extracted using the numerical model. Both models provide a qualitative description of the often cited asymmetric nature of the response and recovery for hyperbolic-type response naked optical film sensors. It is envisaged that the models will help in the interpretation of the response and recovery behaviour exhibited by many naked optical film sensors and might be especially apposite when the analyte is a gas.
Resumo:
Under inflammatory conditions, macrophages can differentiate into different functional subtypes. We show that bone marrow-derived macrophages constitutively express different levels of various complement-related genes. The relative expression levels are C1qb > Crry > CFH > C3 > C1r > CFB > DAF1 > CD59a > C2 > C1INH > C1s > C4. Upon activation, the expression of C1r, C1s, C3, C2, CFB, and C1INH was up-regulated, and CFH, CD59a, and DAF1, down-regulated in M1 (induced by interferon-? + lipopolysaccharides (LPS)) and M2b (induced by immune complex + LPS) macrophages. The expression of C4 and CFH was slightly up-regulated in interleukin (IL)-10-induced M2c macrophages. Complement gene expression in IL-4-induced M2a macrophages was weakly down-regulated as compared to resting M0 macrophages. Higher levels of C3, C1INH, and CFB but lower levels of CFH expression in M1 and M2b macrophage suggests that they may be involved in the alternative pathway of complement activation during inflammation.
Resumo:
Groundwater flow in hard-rock aquifers is strongly controlled by the characteristics and distribution of structural heterogeneity. A methodology for catchment-scale characterisation is presented, based on the integration of complementary, multi-scale hydrogeological, geophysical and geological approaches. This was applied to three contrasting catchments underlain by metamorphic rocks in the northern parts of Ireland (Republic of Ireland and Northern Ireland, UK). Cross-validated surface and borehole geophysical investigations confirm the discontinuous overburden, lithological compartmentalisation of the bedrock and important spatial variations of the weathered bedrock profiles at macro-scale. Fracture analysis suggests that the recent (Alpine) tectonic fabric exerts strong control on the internal aquifer structure at meso-scale, which is likely to impact on the anisotropy of aquifer properties. The combination of the interpretation of depth-specific hydraulic-test data with the structural information provided by geophysical tests allows characterisation of the hydrodynamic properties of the identified aquifer units. Regionally, the distribution of hydraulic conductivities can be described by inverse power laws specific to the aquifer litho-type. Observed groundwater flow directions reflect this multi-scale structure. The proposed integrated approach applies widely available investigative tools to identify key dominant structures controlling groundwater flow, characterising the aquifer type for each catchment and resolving the spatial distribution of relevant aquifer units and associated hydrodynamic parameters.