106 resultados para Wireless power transmission


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports on the design methodology and experimental characterization of the inverse Class-E power amplifier. A demonstration amplifier with excellent second and third harmonic-suppression levels has been designed, constructed, and measured. The circuit fabricated using a 1.2-min gate-width GaAs MESFET is shown to be able to deliver 22-dBm output power at 2.3 GHz. The amplifier achieves a peak power-added efficiency of 64 % and drain efficiency of 69 %, and exhibits 11.6 dB power gain when operated from a 3-V supply voltage. Comparisons of simulated and measured results are given with good agreement between them being obtained. Experimental results are presented for the amplifier's response to Gaussian minimum shift keying modulation, where a peak error vector modulation value of 0.6% is measured.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper details the implementation and operational performance of a minimum-power 2.45-GHz pulse receiver and a companion on-off keyed transmitter for use in a semi-active duplex RF biomedical transponder. A 50-Ohm microstrip stub-matched zero-bias diode detector forms the heart of a body-worn receiver that has a CMOS baseband amplifier consuming 20 microamps from +3 V and achieves a tangential sensitivity of -53 dBm. The base transmitter generates 0.5 W of peak RF output power into 50 Ohms. Both linear and right-hand circularly polarized Tx-Rx antenna sets were employed in system reliability trials carried out in a hospital Coronary Care Unit, For transmitting antenna heights between 0.3 and 2.2 m above floor level, transponder interrogations were 95% reliable within the 67-m-sq area of the ward, falling to an average of 46 % in the surrounding rooms and corridors. Overall, the circular antenna set gave the higher reliability and lower propagation power decay index.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An analysis of the operation of a series-L/parallel-tuned class-E amplifier and its equivalence to the classic shunt-C/series-tuned class-E amplifier are presented. The first reported closed form design equations for the series-L/parallel-tuned topology operating under ideal switching conditions are given. Furthermore, a design procedure is introduced that allows the effect that nonzero switch resistance has on amplifier performance efficiency to be accounted for. The technique developed allows optimal circuit components to be found for a given device series resistance. For a relatively high value of switching device ON series resistance of 4O, drain efficiency of around 66% for the series-L/parallel-tuned topology, and 73% for the shunt-C/series-tuned topology appear to be the theoretical limits. At lower switching device series resistance levels, the efficiency performance of each type are similar, but the series-L/parallel-tuned topology offers some advantages in terms of its potential for MMIC realisation. Theoretical analysis is confirmed by numerical simulation for a 500mW (27dBm), 10% bandwidth, 5 V series-L/parallel-tuned, then, shunt-C/series-tuned class E power amplifier, operating at 2.5 GHz, and excellent agreement between theory and simulation results is achieved. The theoretical work presented in the paper should facilitate the design of high-efficiency switched amplifiers at frequencies commensurate with the needs of modern mobile wireless applications in the microwave frequency range, where intrinsically low-output-capacitance MMIC switching devices such as pHEMTs are to be used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A combined antennas and propagation study has been undertaken with a view to directly improving link conditions for wireless body area networks. Using tissue-equivalent numerical and experimental phantoms representative of muscle tissue at 2.45 GHz, we show that the node to node [S-21] path gain performance of a new wearable integrated antenna (WIA) is up to 9 dB better than a conventional compact Printed-F antenna, both of which are suitable for integration with wireless node circuitry. Overall, the WIA performed extremely well with a measured radiation efficiency of 38% and an impedance bandwidth of 24%. Further benefits were also obtained using spatial diversity, with the WIA providing up to 7.7 dB of diversity gain for maximal ratio combining. The results also show that correlation was lower for a multipath environment leading to higher diversity gain. Furthermore, a diversity implementation with the new antenna gave up to 18 dB better performance in terms of mean power level and there was a significant improvement in level crossing rates and average fade durations when moving from a single-branch to a two-branch diversity system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A graphical method is presented for determining the capability of individual system nodes to accommodate wind power generation. The method is based upon constructing a capability chart for each node at which a wind farm is to be connected. The capability chart defines the domain of allowable power injections at the candidate node, subject to constraints imposed by voltage limits, voltage stability and equipment capability limits being satisfied. The chart is first derived for a two-bus model, before being extended to a multi-node power system. The graphical method is employed to derive the chart for a two-node system, as well as its application to a multi-node power system, considering the IEEE 30-bus test system as a case study. Although the proposed method is derived with the intention of determining the wind farm capacity to be connected at a specific node, it can be used for the analysis of a PQ bus loading as well as generation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The power-handling capabilities of helical resonator filters for space applications are discussed. Emerging difficulties due to the multipaction effects are highlighted. A method is proposed to increase specified power handling without significantly sacrificing the size/quality factor. Experimental verification is attained by means of a fabricated prototype for which measured filter response and multipaction test results are obtained and presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A self-tracking (aligning) radio communications system based on the principle of modulated backscatter detection is presented here. Using amplitude-modulated backscatter from a co-operating target, a modified IQ demodulation scheme is used to reproduce automatically and in real time both the received and conjugate of the received phase of an incoming signal. The phase conjugated demodulated IF signal can have incoming backscattered data removed and new data are inserted before being up-converted using IQ single side-band generation so that retro-directive re-transmission can be made to occur. In the absence of the backscattered modulation signal, no phase conjugation and hence no retro-directed re-transmission can occur. The system reported is therefore inherently self-authenticating a facility not readily available from previously reported retro-directive self-tracking systems. © 2010 © The Institution of Engineering and Technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Orthogonal frequency division multiplexing (OFDM) requires an expensive linear amplifier at the transmitter due to its high peak-to-average power ratio (PAPR). Single carrier with cyclic prefix (SC-CP) is a closely related transmission scheme that possesses most of the benefits of OFDM but does not have the PAPR problem. Although in a multipath environment, SC-CP is very robust to frequency-selective fading, it is sensitive to the time-selective fading characteristics of the wireless channel that disturbs the orthogonality of the channel matrix (CM) and increases the computational complexity of the receiver. In this paper, we propose a time-domain low-complexity iterative algorithm to compensate for the effects of time selectivity of the channel that exploits the sparsity present in the channel convolution matrix. Simulation results show the superior performance of the proposed algorithm over the standard linear minimum mean-square error (L-MMSE) equalizer for SC-CP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a hybrid transmission technique based on adaptive code-to-user allocation and linear precoding for the downlink of phase shift keying (PSK) based multi-carrier code division multiple access (MC-CDMA) systems. The proposed scheme is based on the separation of the instantaneous multiple access interference (MAI) into constructive and destructive components taking into account the dependency on both the channel variation and the instantaneous symbol values of the active users. The first stage of the proposed technique is to adaptively distribute the available spreading sequences to the users on a symbol-by-symbol basis in the form of codehopping with the objective to steer the users' instantaneous crosscorrelations to yield a favourable constructive to destructive MAI ratio. The second stage is to employ a partial transmitter based zero forcing (ZF) scheme specifically designed for the exploitation of constructive MAI. The partial ZF processing decorrelates destructive interferers, while users that interfere constructively remain correlated. This results in a signal to interference-plus-noise ratio (SINR) enhancement without the need for additional power-per-user investment. It will be shown in the results section that significant bit error rate (BER) performance benefits can be achieved with this technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A vaginally-worn temperature telemeter may be used by women to chart their basal body temperature for ovulation detection. The telemeter uses a temperature to pulse width converter to key a Colpitts oscillator which is controlled in frequency by a 418 MHz SAW resonator. The circuit’s tank inductor acts as a compact, multi-turn loop antenna with a radiated power in isolation of around 1 uW. The transmission characteristics of the system are affected by the proximity of the human body, which acts as an electrically-large lossy dielectric. The RF link-budget must allow for the reduction in total emitted power, directional body-induced fading, and polarization effects. The polar power patterns of the telemeter were measured for both isolated and in-situ cases, using horizontal and vertical polarization. The power patterns were numerically integrated to determine relative emitted power, and a reference dipole used to determine the emitted power for the isolated device. In isolation the telemeter radiation is vertically polarized and isotropic in nature. With the telemeter in-situ, total body absorption was found to be over 20 dB, with directional fades of up to 40 dB; there was extensive cross-polarization, with up to 60% of radiated power horizontally polarized. With limited radiated power and directional fading, the operating range for the telemeter is limited to single room operation (less than 10m). The majority of RF radiation is absorbed by the body, but the radiation hazard is negligible due to the low power level of the device. The high level of cross-polarization suggests that either horizontal or vertically polarized base-station antennas may be used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Radio-based signalling devices will play an important role in future generations of remote patient monitoring equipment, both at home and in hospital. Ultimately, it will be possible to sample vital signs frompatients, whatever their location and without them necessarily being aware that a measurement is being taken. This paper reviews currentmethods for the transmission by radio of physiological parameters over ranges of 0.3, 3 and 30 m, and describes the radiofrequency hardware required and the carrier frequencies commonly used. Future developments, including full duplex systems and the use of more advanced modulation schemes, are described. The paper concludeswith a case studyof a humantemperature telemeter built to indicateovulation. Clinical results clearly show the advantage to be had in adopting radio biotelemetry in this instance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In ultra-low data rate wireless sensor networks (WSNs) waking up just to listen to a beacon every superframe can be a major waste of energy. This study introduces MedMAC, a medium access protocol for ultra-low data rate WSNs that achieves significant energy efficiency through a novel synchronisation mechanism. The new draft IEEE 802.15.6 standard for body area networks includes a sub-class of applications such as medical implantable devices and long-term micro miniature sensors with ultra-low power requirements. It will be desirable for these devices to have 10 years or more of operation between battery changes, or to have average current requirements matched to energy harvesting technology. Simulation results are presented to show that the MedMAC allows nodes to maintain synchronisation to the network while sleeping through many beacons with a significant increase in energy efficiency during periods of particularly low data transfer. Results from a comparative analysis of MedMAC and IEEE 802.15.6 MAC show that MedMAC has superior efficiency with energy savings of between 25 and 87 for the presented scenarios. © 2011 The Institution of Engineering and Technology.