147 resultados para WASTE POLLUTION
Resumo:
Assessment of elevated concentrations of potentially toxic elements (PTE) in soils and the association with specific soil parent material have been the focus of research for a number of years. Risk-based assessment of potential exposure scenarios to identified elevated PTE concentrations has led to the derivation of site- and contaminant-specific soil guideline values (SGVs), which represent generic assessment criteria (GACs) to identify exceeded levels that may reflect an unacceptable risk to human health. A better understanding of the ‘bioavailable’ or ‘bioaccessible’ contaminant concentrations offers an opportunity to better refine contaminant exposure assessments. Utilizing a comprehensive soil geochemical dataset for Northern Ireland provided by the Tellus Survey (GSNI) in conjunction with supplementary bioaccessibility testing of selected soil samples following the Unified BARGE Method, this paper uses exploratory data analysis and geostatistical analysis to investigate the spatial variability of pseudo-total and bioaccessible concentrations of As, Cd, Co, Cr. Cu, Ni, Pb, U, V and Zn. The paper investigates variations in individual element concentrations as well as cross-element correlations and observed lithological/pedological associations. The analysis of PTE concentrations highlighted exceeded levels of GAC values for V and Cr and exceeded SGV/GAC values for Cd, Cu, Ni, Pb, and Zn. UBM testing showed that for some soil parent materials associated with elevated PTE concentrations e.g. the Antrim Lava Group with high Ni concentrations, the measured oral bioaccessible fraction was relatively low. For other soil parent materials with relatively moderate PTE concentrations, measured oral bioaccessible fraction was relatively high (e.g. the Gala Sandstone Group of the Southern Uplands-Down Longford Terrain). These findings have implications for regional human health risk assessments for specific PTEs.
Resumo:
Constructed wetland systems (CWS) have been used as a low cost bio-filtration system to treat farm wastewater. While studies have shown that CWS are efficient in removing organic compounds and pathogens, there is limited data on the presence of hormones in this type of treatment system. The objective of this study was to evaluate the ability of the CWS to reduce estrogenic and androgenic hormone concentration in dairy wastewater. This was achieved through a year long study on dairy wastewater samples obtained froma surface flow CWS. Analysis of hormonal levels was performed using a solid phase extraction (SPE) sample clean-up method, combined with reporter gene assays (RGAs) which incorporate relevant receptors capable of measuring total estrogenic or androgenic concentrations as low as 0.24 ng L1 and 6.9 ng L1 respectively. Monthly analysis showed a mean removal efficiency for estrogens of 95.2%, corresponding to an average residual concentration of 3.2 ng L1 17b-estradiol equivalent (EEQ), below the proposed lowest observable effect concentration (LOEC) of 10 ng L1. However, for one month a peak EEQ concentration of 115 ng L1 was only reduced to 18.8 ng L1. The mean androgenic activity peaked at 360 ng L1 and a removal efficiency of 92.1% left an average residual concentration of 32.3 ng L1 testosterone equivalent (TEQ). The results obtained demonstrate that this type of CWS is an efficient system for the treatment of hormones in dairy wastewater. However, additional design improvements may be required to further enhance removal efficiency of peak hormone concentrations.
Resumo:
A microwave reactor system was investigated as a potential technique to maximize sugar yield for the hydrolysis of municipal solid waste for ethanol production. Specifically, dilute acid hydrolysis of a-cellulose and waste cellulosic biomass (grass clippings) with phosphoric acid was undertaken within the microwave reactor system. The experimental data and reaction kinetic analysis indicate that the use of a microwave reactor system can successfully facilitate dilute acid hydrolysis of cellulose and waste cellulosic biomass, producing high yields of total sugars in short reaction times. The maximum yield of reducing sugars was obtained at 7.5% (w/v) phosphoric acid and 160 degrees C, corresponding to 60% of the theoretical total sugars, with a reaction time of 5 min. When using a very low acid concentration (0.4% w/v) for the hydrolysis in the microwave reactor, it was found that 10 g of total sugars/100 g dry mass was produced, which is significant considering the low acid concentration. When hydrolyzing grass clippings using the microwave reactor, the optimum conditions were an acid concentration of 2.5% (w/v), 175 degrees C with a 15 min reaction time, giving 18 g/100 g dry mass of total sugars, with xylose being the sugar with the highest yield. It was observed that pentose sugars were more easily formed but also more easily degraded, these being significantly affected by increases in acid concentration and temperature. Kinetic modeling of the data indicated that the use of microwave heating may account for an increase in reaction rate constant, k(1), found in this study in comparison with conventional systems described in the literature.
Resumo:
Nitrogen Dioxide (NO2) is known to act as an environmental trigger for many respiratory illnesses. As a pollutant it is difficult to map accurately, as concentrations can vary greatly over small distances. In this study three geostatistical techniques were compared, producing maps of NO2 concentrations in the United Kingdom (UK). The primary data source for each technique was NO2 point data, generated from background automatic monitoring and background diffusion tubes, which are analysed by different laboratories on behalf of local councils and authorities in the UK. The techniques used were simple kriging (SK), ordinary kriging (OK) and simple kriging with a locally varying mean (SKlm). SK and OK make use of the primary variable only. SKlm differs in that it utilises additional data to inform prediction, and hence potentially reduces uncertainty. The secondary data source was Oxides of Nitrogen (NOx) derived from dispersion modelling outputs, at 1km x 1km resolution for the UK. These data were used to define the locally varying mean in SKlm, using two regression approaches: (i) global regression (GR) and (ii) geographically weighted regression (GWR). Based upon summary statistics and cross-validation prediction errors, SKlm using GWR derived local means produced the most accurate predictions. Therefore, using GWR to inform SKlm was beneficial in this study.
Resumo:
The survival of pathogenic bacteria was investigated during the operation of a full-scale anaerobic digester which was fed daily and operated at 28-degrees-C. The digester had a mean hydraulic retention time of 24 d. The viable numbers of Escherichia coli, Salmonella typhimurium, Yersinia enterocolitica, Listeria monocytogenes and Campylobacter jejuni were reduced during mesophilic anaerobic digestion. Escherichia coli had the smallest mean viable numbers at each stage of the digestion process. Its mean T90 value was 76-9 d. Yersinia enterocolitica was the least resistant to the anaerobic digester environment; its mean T90 value was 18.2 d. Campylobacter jejuni was the most resistant bacterium; its mean T90 value was 438.6 d. Regression analysis showed that there were no direct relationships between the slurry input and performance of the digester and the decline of pathogen numbers during the 140 d experimental period.
Resumo:
Rural point sources of phosphorus (P), including septic tank systems, provide a small part of the overall phosphorus budget to surface waters in agricultural catchments but can have a disproportionate impact on the low flow P concentration of receiving rivers. This has particular importance as the discharges are approximately constant into receiving waters and these have restricted dilution capacity during ecologically sensitive summer periods. In this study, a number of identified high impact septic systems were replaced with modern sequential batch reactors in three rural catchments during a monitoring period of 4 years. Sub-hourly P monitoring was conducted using bankside-analysers. Results show that strategic replacement of defective septic tank systems with modern systems and polishing filters decreased the low flow P concentration of one catchment stream by 0.032 mg TP L- 1 (0.018 mg TRP L- 1) over the 4 years. However two of the catchment mitigation efforts were offset by continued new-builds that increased the density of septic systems from 3.4 km- 2 to 4.6 km- 2 and 13.8 km- 2 to 17.2 km- 2 and subsequently increased low flow P concentrations. Future considerations for septic system mitigation should include catchment carrying capacity as well as technology changes.