88 resultados para Volume holographic lenses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements of plasma parameters, including H- ion densities, made in conjunction with wall temperature, visible and vacuum ultraviolet emission spectroscopy verify that there is little caesium in the plasma volume of the H- ion source. Surface work function measurements indicate that there is significant caesium coverage of the inner walls of the ion source. It is found that, as the work function of a test surface decreases due to caesium seeding, the H- ion fraction in the discharge volume increases. These observations combine to indicate that, in the present source, the H- ion enhancement mechanism is a surface dominated effect. (C) 1999 American Institute of Physics. [S0003- 6951(99)04744-0].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we demonstrate a new concept in the production of negative hydrogen ions in a low-pressure multicusp discharge. The discharge voltage is modulated to produce a non-Maxwellian, hot-electron plasma during the current pulse, followed by a cool Maxwellian electron plasma in the post discharge. This procedure, of separating in time the required hot and cold electron plasmas required for volume H- production, is called a temporal filter. The time evolution of the electron energy distribution function is measured using the time-resolved second derivative of a Langmuir probe characteristic. Time-resolved measurements of the negative ion density are made using laser photodetachment. The measurements show that the negative ion density in the center of the source, at a gas pressure of 0.07 Pa, increases by a factor of 2 when the discharge is switched off. At this low pressure the average H- beam current extracted from the source, when operated with a discharge current of 1 A in the pulse modulated mode exceeds the H- beam current from a 5 A continuously operated source. The increase in efficiency of the pulsed source is explained in terms of a two-step H- production mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed to investigate the presence of corpus callosum (CC) volume deficits in a population-based recent-onset psychosis (ROP) sample, and whether CC volume relates to interhemispheric communication deficits. For this purpose, we used voxel-based morphometry comparisons of magnetic resonance imaging data between ROP (n = 122) and healthy control (n = 94) subjects. Subgroups (38 ROP and 39 controls) were investigated for correlations between CC volumes and performance on the Crossed Finger Localization Test (CFLT). Significant CC volume reductions in ROP subjects versus controls emerged after excluding substance misuse and non-right-handedness. CC reductions retained significance in the schizophrenia subgroup but not in affective psychoses subjects. There were significant positive correlations between CC volumes and CFLT scores in ROP subjects, specifically in subtasks involving interhemispheric communication. From these results, we can conclude that CC volume reductions are present in association with ROP. The relationship between such deficits and CFLT performance suggests that interhemispheric communication impairments are directly linked to CC abnormalities in ROP. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Severe sepsis and septic shock are leading causes of death in the intensive care unit (ICU). This is despite advances in the management of patients with severe sepsis and septic shock including early recognition, source control, timely and appropriate administration of antimicrobial agents, and goal directed haemodynamic, ventilatory and metabolic therapies. High-volume haemofiltration (HVHF) is a blood purification technique which may improve outcomes in critically ill patients with severe sepsis or septic shock. The technique of HVHF has evolved from renal replacement therapies used to treat acute kidney injury (AKI) in critically ill patients in the ICU.

Objectives: This review assessed whether HVHF improves clinical outcome in adult critically ill patients with sepsis in an ICU setting.

Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library, 2011, Issue 7); MEDLINE (1990 to August 2011), EMBASE (1990 to August 2011); LILACS (1982 to August 2011), Web of Science (1990 to August 2011), CINAHL (1982 to August 2011) and specific websites.

Selection criteria: We included randomized controlled trials (RCTs) and quasi-randomized trials comparing HVHF or high-volume haemodiafiltration to standard or usual dialysis therapy; and RCTs and quasi-randomized trials comparing HVHF or high-volume haemodiafiltration to no similar dialysis therapy. The studies involved adults in critical care units.

Data collection and analysis: Three review authors independently extracted data and assessed trial quality. We sought additional information as required from trialists.

Main results: We included three randomized trials involving 64 participants. Due to the small number of studies and participants, it was not possible to combine data or perform sub-group analyses. One trial reported ICU and 28-day mortality, one trial reported hospital mortality and in the third, the number of deaths stated did not match the quoted mortality rates. No trials reported length of stay in ICU or hospital and one reported organ dysfunction. No adverse events were reported. Overall, the included studies had a low risk of bias.

Authors' conclusions: There were no adverse effects of HVHF reported.There is insufficient evidence to recommend the use of HVHF in critically ill patients with severe sepsis and or septic shock except as interventions being investigated in the setting of a randomized clinical trial. These trials should be large, multi-centred and have clinically relevant outcome measures. Financial implications should also be assessed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiscale micro-mechanics theory is extensively used for the prediction of the material response and damage analysis of unidirectional lamina using a representative volume element (RVE). Th is paper presents a RVE-based approach to characterize the materi al response of a multi-fibre cross-ply laminate considering the effect of matrix damage and fibre-matrix interfacial strength. The framework of the homogenization theory for periodic media has been used for the analysis of a 'multi-fibre multi-layer representative volume element' (M2 RVE) representing cross-ply laminate. The non-homogeneous stress-strain fields within the M2RVE are related to the average stresses and strains by using Gauss theorem and the Hill-Mandal strain energy equivalence principle. The interfacial bonding strength affects the in-plane shear stress-strain response significantl y. The material response predicted by M2 RVE is in good agreement with the experimental results available in the literature. The maximum difference between the shear stress predicted using M2 RVE and the experimental results is ~15% for the bonding strength of 30MPa at the strain value of 1.1%

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A parallel kinematic machine (PKM) topology can only give its best performance when its geometrical parameters are optimized. In this paper, dimensional synthesis of a newly developed PKM is presented for the first time. An optimization method is developed with the objective to maximize both workspace volume and global dexterity of the PKM. Results show that the method can effectively identify design parameter changes under different weighted objectives. The PKM with optimized dimensions has a large workspace to footprint ratio and a large well-conditioned workspace, hence justifies its suitability for large volume machining.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To evaluate the long-term graft survival in patients with flexible open-loop anterior chamber intraocular lenses (AC IOL). Methods. We retrospectively reviewed the records of patients with aphakic/pseudophakic bullous keratopathy who underwent penetrating keratoplasty and flexible open-loop AC IOL implantation in our institution from 1983 to 1988. Results. 79 eyes from 77 patients were included in the study. Mean follow-up was 50 months (range 1 to 123 months). At last follow-up 61 eyes (77.2%) had clear grafts. Among them, the visual acuity was = 20/40 in 14 eyes (23.0%), 20/50-20/100 in 22 eyes (36.1%), 20/200-20/400 in 9 eyes (14.8%) and = CF in 16 (26.2%). Increment of glaucoma medications and/or glaucoma surgery was the most frequent complication (37 eyes, 46,8%). Cystoid macular edema was newly diagnosed in 10 eyes (12.7%). Conclusions. Flexible, open-loop anterior chamber lens are a viable option in the treatment of patients with aphakic or pseudophakic bullous keratopathy undergoing penetrating keratoplasty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To evaluate the long-term graft survival and complications of flexible, open-loop anterior-chamber intraocular lenses in patients with penetrating keratoplasty for pseudophakic or aphakic bullous keratopathy. Methods. We reviewed charts of all consecutive patients who underwent penetrating keratoplasty for pseudophakic or aphakic bullous keratopathy combined with implantation of a flexible, open-loop, anterior-chamber intraocular lens at our institution between 1983 and 1988. One-hundred one eyes of 99 patients were evaluated. Graft-survival rates were calculated by using the Kaplan-Meier actuarial method. Results. Mean follow-up was 49.8 months (range. 1-144). The probability of graft survival at 1, 2, 4, 6, and 8 years was 93, 87, 78, 65, and 65%, respectively. A total of 25 (24.8%) grafts failed. Progressive corneal edema without signs of rejection was the most common finding in patients with failed grafts (10 eyes, 40%). The most frequent complication observed was newly diagnosed or worsening of preexisting glaucoma (46 eyes, 45.5%). Conclusions. Our long-term results support flexible, open-loop anterior-chamber intraocular lenses as a reasonable option, at the time of penetrating keratoplasty, in patients with pseudophakic and aphakic bullous keratopathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to describe the outcome of patients with filtering blebs who were fit with contact lenses. Methods: We retrospectively studied patients with filtering blebs secondary to glaucoma or cataract surgery who were fit with contact lenses. Eight eyes from seven patients were identified. Results: Five patients (six eyes) were fit with gas permeable contact lenses and two patients (two eyes) were fit with soft contact lenses. Successful fits were achieved in all patients. No complications were observed after a mean follow-up of 64.6±28.5 months. Conclusions: No significant complications were recorded in our series of patients with filtering blebs who were fit with contact lenses. We think that when indications for fitting contact lenses are justified, patients with filtering blebs are acceptable candidates for contact lens use. However, adequate selection of cases, careful contact lens fitting, patient education, and close follow-up are necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the contamination of used disposable soft contact lenses with Acanthamoeba. Methods: We evaluated 51 consecutive disposable soft contact lens wearers in a prospective study. Before their check-up visits, patients were offered a free new contact lens in exchange for donating their old one. The used contact lenses (n=102) were then removed and placed in culture medium for Acanthamoeba. We subsequently investigated patterns of wear and hygiene habits. Results: The mean age of this population was 32.6±11.0 years. The average time of disposable soft contact lens wear was 13.7 hours per day. The contact lenses were disinfected daily with commercial solutions. Twenty-five (49.0%) subjects did not clean their lens cases properly. Acanthamoeba was not isolated from any of the 102 lenses. Conclusions: There were no cases of Acanthamoeba contamination in a small population of disposable soft contact lens wearers who regularly disinfected their lenses with standard commercially available contact lens solutions.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The modern stereologic method of vertical sections was applied to the retina as a means of generating unbiased estimates of three-dimensional structure. The method is illustrated with real data on the volume and surface area of the capillary basement membrane from the central retina of the rat. Novel methods of estimating the volume of retina sampled and of creating accurate vertical sections are described. The advantages of using stereologic methods to generate quantitative information on the three-dimensional structure of the retina are discussed and compared to those of previous quantitative methods that provide data on two-dimensional structure only.