51 resultados para Team Evaluation Models


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract. Single-zone modelling is used to assess different collections of impeller 1D loss models. Three collections of loss models have been identified in literature, and the background to each of these collections is discussed. Each collection is evaluated using three modern automotive turbocharger style centrifugal compressors; comparisons of performance for each of the collections are made. An empirical data set taken from standard hot gas stand tests for each turbocharger is used as a baseline for comparison. Compressor range is predicted in this study; impeller diffusion ratio is shown to be a useful method of predicting compressor surge in 1D, and choke is predicted using basic compressible flow theory. The compressor designer can use this as a guide to identify the most compatible collection of losses for turbocharger compressor design applications. The analysis indicates the most appropriate collection for the design of automotive turbocharger centrifugal compressors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several one-dimensional design methods have been used to predict the off-design performance of three modern centrifugal compressors for automotive turbocharging. The three methods used are single-zone, two-zone, and a more recent statistical method. The predicted results from each method are compared against empirical data taken from standard hot gas stand tests for each turbocharger. Each of the automotive turbochargers considered in this study have notably different geometries and are of varying application. Due to the non-adiabatic test conditions, the empirical data has been corrected for the effect of heat transfer to ensure comparability with the 1D models. Each method is evaluated for usability and accuracy in both pressure ratio and efficiency prediction. The paper presents an insight into the limitations of each of these models when applied to one-dimensional automotive turbocharger design, and proposes that a corrected single-zone modelling approach has the greatest potential for further development, whilst the statistical method could be immediately introduced to a design process where design variations are limited.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Within a defined law framework, the Italian central health system dictates the standards for hospitalization to local care units, which are in turn allowed to establish their own effectiveness criteria. The appropriateness of the hospitalization decision is therefore predetermined at patients admission, whereas its effectiveness relies on the ex post patient well-being as a result of the complex system of reciprocal relations between patients and healthcare agents at the ward level. We consider the outcomes in geriatric wards referring to the national health system, with respect both to patients traits at the individual level and wards/hospital settings. The risk that models the healthcare outcome is accordingly adjusted for covariates at the different levels of analysis (Goldstein & Spiegelhalter, 1996), thus allowing to differentiate among outcomes in terms of the hospitalization structure and, when appropriate, of territorial aggregation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Realistic Evaluation of EWS and ALERT: factors enabling and constraining implementation Background The implementation of EWS and ALERT in practice is essential to the success of Rapid Response Systems but is dependent upon nurses utilising EWS protocols and applying ALERT best practice guidelines. To date there is limited evidence on the effectiveness of EWS or ALERT as research has primarily focused on measuring patient outcomes (cardiac arrests, ICU admissions) following the implementation of a Rapid Response Team. Complex interventions in healthcare aimed at changing service delivery and related behaviour of health professionals require a different research approach to evaluate the evidence. To understand how and why EWS and ALERT work, or might not work, research needs to consider the social, cultural and organisational influences that will impact on successful implementation in practice. This requires a research approach that considers both the processes and outcomes of complex interventions, such as EWS and ALERT, implemented in practice. Realistic Evaluation is such an approach and was used to explain the factors that enable and constrain the implementation of EWS and ALERT in practice [1]. Aim The aim of this study was to evaluate factors that enabled and constrained the implementation and service delivery of early warnings systems (EWS) and ALERT in practice in order to provide direction for enabling their success and sustainability. Methods The research design was a multiple case study approach of four wards in two hospitals in Northern Ireland. It followed the principles of realist evaluation research which allowed empirical data to be gathered to test and refine RRS programme theory. This approach used a variety of mixed methods to test the programme theories including individual and focus group interviews, observation and documentary analysis in a two stage process. A purposive sample of 75 key informants participated in individual and focus group interviews. Observation and documentary analysis of EWS compliance data and ALERT training records provided further evidence to support or refute the interview findings. Data was analysed using NVIVO8 to categorise interview findings and SPSS for ALERT documentary data. These findings were further synthesised by undertaking a within and cross case comparison to explain the factors enabling and constraining EWS and ALERT. Results A cross case analysis highlighted similarities, differences and factors enabling or constraining successful implementation across the case study sites. Findings showed that personal (confidence; clinical judgement; personality), social (ward leadership; communication), organisational (workload and staffing issues; pressure from managers to complete EWS audit and targets), educational (constraints on training; no clinical educator on ward) and cultural (routine task delegated) influences impact on EWS and acute care training outcomes. There were also differences noted between medical and surgical wards across both case sites. Conclusions Realist Evaluation allows refinement and development of the RRS programme theory to explain the realities of practice. These refined RRS programme theories are capable of informing the planning of future service provision and provide direction for enabling their success and sustainability. References: 1. McGaughey J, Blackwood B, O’Halloran P, Trinder T. J. & Porter S. (2010) A realistic evaluation of Track and Trigger systems and acute care training for early recognition and management of deteriorating ward–based patients. Journal of Advanced Nursing 66 (4), 923-932. Type of submission: Concurrent session Source of funding: Sandra Ryan Fellowship funded by the School of Nursing & Midwifery, Queen’s University of Belfast

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Clostridium difficile (C. difficile) is a leading cause of infectious diarrhoea in hospitals. Sending faecal samples for testing expedites diagnosis and appropriate treatment. Clinical suspicion of C. difficile based on patient history, signs and symptoms is the basis for sampling. Sending faecal samples from patients with diarrhoea ‘just in case’ the patient has C. difficile may be an indication of poor clinical management.

Aim: To evaluate the effectiveness of an intervention by an Infection Prevention and Control Team (IPCT) in reducing inappropriate faecal samples sent for C. difficile testing.

Method: An audit of numbers of faecal samples sent before and after a decision-making algorithm was introduced. The number of samples received in the laboratory was retrospectively counted for 12-week periods before and after an algorithm was introduced.
Findings: There was a statistically significant reduction in the mean number of faecal samples sent post the algorithm. Results were compared to a similar intervention carried out in 2009 in which the same message was delivered by a memorandum. In 2009 the memorandum had no effect on the overall number of weekly samples being sent.

Conclusion: An algorithm intervention had an effect on the number of faecal samples being sent for C. difficile testing and thus contributed to the effective use of the laboratory service.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To establish the relationship between myopia and lens opacity. DESIGN: Population-based cross-sectional study. PARTICIPANTS: Two thousand five hundred twenty participants from the Salisbury Eye Evaluation aged 65 to 84 years. METHODS: Participants filled out questionnaires regarding medical history, social habits, and a detailed history of distance spectacle wear. They underwent a full ocular examination. Lens photographs were taken for assessment of lens opacity using the Wilmer grading system. Multivariate logistic regression models using generalized estimating equations were used to analyze the relationship between lens opacity type and degree of myopia, while accounting for potential confounders. MAIN OUTCOME MEASURES: Presence of posterior subcapsular opacity, cortical opacity, or nuclear opacity. RESULTS: Significant associations were found between myopia and both nuclear and posterior subcapsular opacities. For nuclear opacity, the odds ratios (ORs) were 2.25 for myopia between -0.50 diopters (D) and -1.99 D (P<0.001), 3.65 for myopia between -2.00 D and -3.99 D (P<0.001), 4.54 for myopia between -4.00 D and -5.99 D (P<0.001), and 3.61 for myopia -6.00 D or more (P = 0.002). For posterior subcapsular cataracts, ORs were 1.59 for myopia between -0.50 D and -1.99 D (P = 0.11), 3.22 for myopia between -2.00 D and -3.99 D (P = 0.002), 5.36 for myopia between -4.00 D and -5.99 D (P<0.001), and 12.34 for myopia -6.00 D or more (P<0.001). No association was found between myopia and cortical opacity. The association between posterior subcapsular opacity and myopia was equally strong for those wearing glasses by age 21 years and for those without glasses; for nuclear opacity, significantly higher ORs were found for myopes who started wearing glasses after age 21. CONCLUSIONS: These results confirm the previously reported association between myopia, posterior subcapsular opacity, and nuclear opacity. Furthermore, the strong association between early spectacle wear and posterior subcapsular opacity among myopes, absent for nuclear opacity, suggests that myopia may precede opacity in the case of posterior subcapsular opacity, but not nuclear opacity. Measures of association between posterior subcapsular opacity and myopia were stronger in the current study than have previously been found. Longitudinal studies to confirm the association are warranted.